Sigler Controls

Technical Development
Program
SIGLER CONTROLS TDP

o Define BIOT and associated industries

o Learn fundamental Controls building blocks

o Understand 3rd Party Integration challenges


SIGLER CONTROLS TDP

Part 1
BUILDING Internet of Things
IOT

INTERNET OF THINGS aka “IOT

First coined in 1999

26 Billion Things by 2020

$6.2 Trillion economic impact by 2025


FEEL THE HYPE

Hype Cycle for Emerging Technologies


SEGMENT DEFINITIONS

Building Automation and Control System


all products and engineering services for automatic
controls, interlocks, monitoring, and optimization
aka: BMS Building Management System
BAS Building Automation System
BACS SEGMENT SIZE

World BACS Segment is currently growing at


10% - 30% CAGR thru 2022 and will be
estimated at a value of $70B – $100B

Controls & SW

Field Value Add


Actuators

Valves

Sensors

Other
BACS EXAMPLE
SEGMENT DEFINITIONS

Building Energy Management System


Software-based system that helps manage, control
and monitor building technical services (HVAC,
lighting etc.) and the energy consumption of
devices related to the building use.
BEMS EXAMPLE
SEGMENT DEFINITIONS

Integrated Building Management System


BACS integrated with other building subsystems,
such as fire systems and security systems
IBMS EXAMPLE
SEGMENT DEFINITIONS

BUILDING Internet of Things


all the components in a building that could be
connected to the network (the Internet) for the purpose
of creating operational efficiencies, reducing energy
consumption, improving occupant experiences
BIOT EXAMPLE
BIOT – WHAT BIG DATA ENABLES
SIGLER CONTROLS TDP

Part 4
What is DDC?
WHAT IS DDC?

o Direct Digital Control of an HVAC system

o A method of monitoring and controlling


HVAC system performance by collecting,
processing, and sending information using
sensors, actuators, and microprocessors
WHAT IS A POINT?

o A point is ANY input or output


device used to monitor and
control the overall or specific
performance of equipment
FOUR KINDS OF POINTS

AI Analog input - a sensor that monitors physical variable data

BI Binary input - a sensor that monitors status; ON/OFF

AO Analog output - a physical action of a proportional device in the


controlled equipment

BO Binary output - changes or maintains device status; ON/OFF


POINT IDENTIFICATION EXERCISE

Think of a sensor, status or


Is it analog (A) or Is it an input (I)
action device used as the
(B) Binary? or an output (O)?
control point.
Supply air temperature (SAT) A I
Supply fan start/stop (SF) B O
Return air relative humidity A I
Hot water pump status (PMPS) B I
Cooling coil valve (CCV) A O
Variable frequency drive (VFD) A O
Filter Status (FLTS) B I
Boiler able/disable (BLR) B O
CLOSED LOOP CONTROL

Controller Device
BI AI Microprocessor AO BO
Inputs that digitally Outputs
processes inputs
and sends
REACTIONS commands to ACTIONS
create outputs

…is accomplished by the control signal


being sent to the controlled device with
constant feedback from the sensor/status
device providing input to the controller.

The HVAC system


(Controlled device)
EXERCISE – AHU W/ECONOMIZER
ALGORITHMS:
BO-TIMECLK BO-COOLING ALM-FILTER
AO-ECONO BO-HEATING DCV

POINTS LIST EXAUST AIR RETURN AIR

A N A LOG B IN A R Y A N A LOG B IN A R Y
IN PU T IN PU T OU T PU T O U T PU T

SPT SFS MAD SF #9 ACTUATOR

#10 #11
SAT FTLR DX1
CO2 ENTH DX2 OUTSIDE AIR F C H SUPPLY AIR

#2
I O E
L O A

OAT HS1
T L T
E
R (2) (2)

#8
HS2 T E

#4
T

#7 #6 #3

SPACE CO2
SPACE SENSOR
SENSOR

#1 #5
Knowledge Check
Sigler Controls TDP
A Programmable Thermostat is a
Direct Digital Controller

True
Correct

False
Incorrect

Reset Questions
Closed Loop Control is accomplished
without constant feedback from the
device being controlled

True
Incorrect

False
Correct

Reset Questions
WSHP CENTRAL PLANT
1
EXERCISE
PAGE
Fill in the Points List

Workbook

A N A LOG B IN A R Y A N A LOG B IN A R Y
IN PU T IN PU T OU T PU T O U T PU T

CWS CTFS P1VFD P1


CWR B1ALM P2VFD P2
HWS P1STAT CTVFD B1
DP P2STAT CTSP
CTF
SIGLER CONTROLS TDP

Part 6
Third Party Integration
THIRD PARTY INTEGRATION

Sharing Carrier equipment data with others!

Honeywell, Siemens, Alerton, etc.

Carrier
3rd party BAS Equipment
(Building Automation System)

System Integrator = Third Party


BACNET MS/TP & BACNET IP
Open PIC
Carrier (Product Integrated Controller)
Equipment
BACnet
MS/TP i-Vu Open Router
(XT-RB)

BACnet
IP
CCN PIC
(Product Integrated Controller)

BACnet
MS/TP

CCN
UPC Open Factory Installed
UPC Open Field Installed (OPN-UPC)
THIRD PARY INTEGRATION

IP Network

Third Party Third Party


Router WEB Server

Device Network

Carrier Gateway
CCN Network

Carrier Factory Installed ComfortLink Controls


POINTS LIST

• Third party points list


• Identifies what data will be relayed to the BAS
Knowledge Check
Sigler Controls TDP
Who must supply the third party
Points List to the integrator

The manufacture of the equipment being integrated


Correct

The Controls Contractor


Incorrect

The Mechanical Engineer


Incorrect

Reset Questions
SIGLER CONTROLS TDP