OIL ANALYSIS REPORT

Customer Name : PT. SAPTA INDRA SEJATI Unit Number : DT020-0014 Viscosity@100°C :
For Attention : Component : ENGINE Viscosity@40°C :
Location : SANGA - SANGA Component Matrix : EG LT TBN :
Unit Model : FM09 Oil Matrix : GEN DSO 15W-40

TEST DETAILS Overall Analysis Result:

Lab. Number B10049693 B11002797 B11005412 B11009646 B11011356


Sampling Date 2010-10-31 2011-01-07 2011-01-27 2011-02-26 2011-03-07
Received Date 2010-11-20 2011-01-19 2011-02-05 2011-03-07 2011-03-18
Report Date 2010-11-21 2011-01-20 2011-02-06 2011-03-08 2011-03-21
Hours on Oil 250 250 250 250 250
Hours On Unit 8500 9080 9238 9596 11079
Lube Oil Name PERTAMINA 15W-40 PERTAMINA 15W-40 PERTAMINA 15W-40 PERTAMINA 15W-40 PERTAMINA 15W-40 NORMAL
Oil Change Yes Yes Yes Yes Yes
Physical Test Unit Method Test Value Attention Urgent
Visc@40C cSt ASTM D445 / /
Visc@100C cSt ASTM D445 13.21 13.09 13.05 13.99 12.5/16.3 11.25/17.93
TBN mg KOH/g ASTM D2896 0 10.2 10.24 9.92 9.58 6.05 4.4
Metal Additive Warning Limit
Magnesium (Mg) ppm ASTM D5185 0/0 8 8 9 7
Calcium (Ca) ppm ASTM D5185 2/0 4163 3871 3968 4136
Zinc (Zn) ppm ASTM D5185 3/0 1035 1250 1072 1091
Molybdenum (Mo) ppm ASTM D5185
Boron ppm ASTM D5185 0
Phosphor ppm ASTM D5185 0
Contaminant
Natrium (Na) ppm ASTM D5185 3/0 5 4 4 4 35 50
Potassium (K) ppm ASTM D5185
Silicon (Si) ppm ASTM D5185 0/0 3 2 3 3 30 45
Fuel Dilution %v ASTM E2412 0 0 0 0 0 2 3
Water Content %v ASTM E2412 0/0 0 0 0 0 0.1 0.2
Glycol %v ASTM E2412 0/0 0 0 0 0 2 3
Wear Metal
Iron (Fe) ppm ASTM D5185 4/0 11 8 12 9 50 80
Copper (Cu) ppm ASTM D5185 2/0 1 1 8 1 20 30
Alumunium (Al) ppm ASTM D5185 1/0 2 2 2 2 18 25
Chromium (Cr) ppm ASTM D5185 1/0 0 0 0 0 10 15
Nickel (Ni) ppm ASTM D5185 1 1 1 0 5 10
Tin (Sn) ppm ASTM D5185 10 20
Lead (Pb) ppm 1 1 0 3 15 25
PQ Index -/ 1 0 1 0
FTIR Warning Limit
Soot Abs/0.1mm ASTM E2412 0/ 12.9 12.9 16.82 24.14 51.16 77.61
Oxidation Abs/0.1mm ASTM E2412 0/0 0 0 0 0.01 0.2 0.4
Nitration Abs/0.1mm ASTM E2412 0/0 0 0 0 0.01 0.2 0.4
Sulfation Abs/0.1mm ASTM E2412 1/ 0 0 0 0.01 0.2 0.4
Other Analysis
ISO CODE - ISO 4406 - - - - / /

Source of Abnormality
--

Action to be taken
Hasil analisa dari parameter yang diuji menunjukkan kondisi Normal. Lakukan resampling 250 Jam berikutnya atau sesuai rekomendasi manufacture.