Specifications

USN 60
Portable Flaw Detector

Damping
50, 75, 150, 1000 ohms
Bandwidth (amplifier bandpass)
0.25 to 25 MHz with10 selectable settings
including broadband
Gate Monitors
Two independent flaw gates controllable over
entire sweep range
Measurement Modes
Zero-to-first, multi-echo with selectable flank
or peak detection
Base Instrument Package Specifications
Rectification
USN 60 Portable Ultrasonic Flaw Detector Range Positive halfwave, negative halfwave,
with Hi-Resolution Color LCD Display 0.040” to 1100” (1 to 27,940 mm) at steel fullwave, RF
NiMH-128 6 ea. D-size Rechargeable NiMH velocity; range selectable in fixed steps or
Batteries, 9.0 amp hour Reject (suppression)
continuously variable
0 to 80% Linear
BPSN Detachable Battery Frame Material Velocity
BC-809 Battery Charger
Units
Continuously adjustable from .0098 to
Inch, millimeter, or microsecond selectable
AC-373 AC Power Supply .6299 inches/microsecond (250 to 16,000
m/second); 65 selectable material velocities Operating Temperature
LCD-139 Clear, field replaceable, LCD
0 to 55º C (32 to 130º F); -25 to 70 º C (-13 to
Screen Overlays (pkg. 10) Display Delay
158ºF ) storable
OP-163 Operating Manual -20 to 3498 microseconds in steel
(dependent on range) Languages
Certificate of Conformity
Selectable English, German, French, Spanish,
Probe Delay/Zero Offset
Italian, Portuguese, Dutch, Finnish,
Accessories 0 to 999.9 microseconds
Norwegian, Swedish, Danish, Romanian,
SCC-071 Soft Carry Case with padded Damping Czech, Slovenian, Russian
adjustable shoulder strap & light shield 50, 75, 150, 1000 ohms
Probe Connectors
SAP-112 Soft Accessory Pouch, detachable, Gain BNC or Lemo selectable at order
for use with soft carry case 0 to 110 dB adjustable in selectable steps
Keypad
UDFW UltraDOC 4 Windows™ 0.1, 0.5, 1.0, 2.0, 6.0, user definable, and
International symbols
Documentation Software locked
PCCBL-841 9 pin Serial PC Cable
Battery Power
Test Modes
6 D-size NiMH (9.0 Ah); NiCad or alkaline cells
PRTCBL-518 Serial Printer Cable Pulse echo, dual, and thru-transmission
substitutable
PRTCBL-842 Parallel Printer Interface Cable Pulser Battery Life
REM-514 Remote Copy Hand Switch Spike/excitation pulse
Up to 6 hours on NiMH, 9.0 Ah batteries
FS-951 Remote Copy Foot Switch Pulse Repetition Frequency Size
LCC-315 Heavy-Duty, Lockable Transport Autolow, autohigh, manually adjustable from
11.1” W x 6.75” H x 6.25”D (282 x 171 x 159
Case 15 to 6000 Hz in 5 Hz increments, external
mm)
trigger
I/O-398 Real Time I/O Cable (DB15 Weight
termination at instrument only) Pulse Energy
6.6 lbs. (3.0 kg) with NiMH batteries; 3.5 lbs.
EAA-008 External Audible Alarm Low, High
(1.6 kg) without batteries
MS – 464 Master/Slave Interconnect Cable
Warranty Inspection Memo, Notes, Header
2 year conditional warranty on parts and
Dedicated Key Functions User definable memo (up to 252 characters),
labor; free 2nd year contingent upon return of Test header (nine 16-character lines), & 7 (16-
unit to Krautkramer within 13 months of Displays the test menu, coarse range character) thickness reading notes to further
purchase for recertification markers, then display delay & range under document inspection conditions on a per file
the A-scan upon successive key presses basis
Outputs
Home Options
Returns instrument to main menu
TTL Go/NoGo
Three independently assignable outputs; Question Mark • DAC/TCG –428 Multiple Curve DAC
instantaneous, timed, latched with visual LED Displays help text for the four active (Distance Amplitude Curve)/TCG (Time
and audible horn alarms parameters along right side of display Corrected Gain) for echo amplitude
adjustment and evaluation, 40 dB dynamic
Analog Freeze range, 12 dB/ microsecond slope, record
Four independently assignable outputs Freezes the displayed A-scan image up to 16 points, recorded points are
Amplitude according to the setting for the freeze mode individually editable, new points can be
0 to 100% full screen ht. directly in the configuration menu (all, peak std., inserted. Display four additional curves
correspond to 0 to 2.5V compare, envelope with selectable based upon dB offset feature from
Thickness (TOF) persistence) originally recorded DAC curve. TCG
0V corresponds to the value on the left Copy attenuation and transfer correction features
side of the screen or display delay; 2.5V enable use on other materials and surface
Sends information to the on-board
corresponds to the value on the right side conditions.
datalogger or I/O port
of the screen or range
• DGS – 692 displays a cur ve for a
I/O Port Data Storage & Documentation par ticular gain of an equivalent
Bidirectional RS232, baud rate selectable up reflector size as a function of the
to 115, 200, direct reports to printers Memory distance between the probe and the
(including HP DeskJet & LaserJet parallel Minimum 200 datasets store all instrument reflector for 25 selectable narrow–
printers) operating parameters plus A-scan; stored banded probes
datasets can be easily previewed and recalled
• IF Interface Gate – 507 for
Color LCD Display for quick, repeatable instrument setup
automatic start of the display, Gates A
Memory Retention or B, and/or DAC/TCG for immersion
Display
2 years testing applications. IF Advanced
3.875” X 5.25” ( 98 x 133 mm), 640 x 480 pixels
VGA, color, active matrix LCD with CCFL backlight; Alphanumeric Thickness Datalogger features allow inter face offset
brightness control; 4 selectable color schemes; 8 Up to 99,999 thickness readings with up to 7 adjustments and display of actual
selectable A-scan colors (16-character) user defined Notes per reading water path distance
can be stored in three flexible, powerful file • BEA (Backwall Echo Attenuator) – 541
A-scan Size structures. 14-character file names with easy Option allows independent gain control of
440 x 401 pixels in normal mode, 440 x 201
file navigation and viewing of both the A- the region under Gate B for backwall echo
in ½ screen mode
Scan and thickness data provided by ½ monitoring
A-scan Update Rate screen testing mode. Thickness readings can
• VGA–553 Output Option provides an
60 Hz be stored, viewed, cleared, or output directly
easy way to connect to a PC monitor or
to a printer.
A-scan Waveform Selections PC projector for viewing by large
Hollow, filled, smart hollow, smart filled Thickness File Structures audiences or training purposes
Linear (sequential), Grid (702 x 702), Custom- • RF–182 Output Option outputs the raw
A-scan Enhance Modes
Linear with auto labeler capability RF waveform via a standard Lemo #00
Sparkle, baseline break, sparkle plus
baseline break Alphanumeric Input connector for fur ther analysis
Quick & easy using two rotary knobs • HISPD – 992 Hi speed digital option
File Preview outputs at 20 x the speed of the
Scroll to preview stored A-scan & file header standard RS232 por t.
Note: Specifications are subject to
change without notice fields to easily select the proper file for recall

AgfaNDT.com
AgfaNDT.com Visit the NDT Super Site, AgfaNDT.com, for more information on Krautkramer's USN 60 and to learn more about
Agfa NDT's complete line of Ultrasonic, X-ray, Digital and Film systems

Agfa NDT Inc. Agfa NDT GmbH Agfa NDT Ltd. Agfa NDT SA
50 Industrial Park Road Robert-Bosch-Str 3 Millburn Hill Road 68, Chemin des Ormeaux
Lewistown, PA 17044 D–50354 Huerth (Efferen) University of Warwick Science Park F–69760, Limonest
USA Germany Coventry, England CV4 7HS France
United Kingdom

You might also like