Professional Documents
Culture Documents
Planning and Design Lab
Planning and Design Lab
Planning and Design Lab
Experiment #:
Title: Enzyme PD
Problem Statement: Plan and Design an experiment to investigate the effect of temperature
Hypothesis: Temperature does affect how fast potatoes break down hydrogen peroxide.
Aim: To investigate how temperature affects the rate at which potatoes break down.
Apparatus: hydrogen peroxide, 3 test tubes, tripod, Bunsen burner; 1 potato, beaker, water,
Method:
4. Place the second potato strip in the freezer for about 30 to 40 minutes.
5. Boil the last piece of potato in a water bath for about 5 minutes.
6. Place the room temperature potato in the it’s respected beaker and add 8 ml of
Room temperature
Frozen
Boiled
VARIABLES
Independent variable: The temperature or state of which each potato temperature is tested.
Dependent variables:
Constant/Control variables:
Control setup: The potato that was left at room temperature without any alteration being
done to it.
Expected Results:
The potato that was placed in the water bath to boil for five minutes should produce
little to no effervescence and would not relight a glowing splint, the potato that was placed in
the freezer to freeze should have fewer effervescence than that of the one that was stored or
Explanation:
Enzymes are 3-dimensional globular proteins that help in speeding up the rate of
reactions without themselves being altered or changed in the process. The potatoes contain an
enzyme known as catalase that helps in breaking down hydrogen peroxide to water and
oxygen. Almost all living organisms contains catalase including us.The boiled potato should
produce little to no effervescence and will not relight a glowing splint because the heat that
was added to the potato deteriorated it so it made it impossible for the catalase enzyme to
break down the hydrogen peroxide. The frozen potato should have a smaller amount of
effervescence of that of the potato that was left to sit at room temperature because the cold
temperature that the potato strip was placed in slowed down its catalytic metabolism to break
down the hydrogen peroxide. So if the reaction is slowed down then that will result in less
effervescence seen during the reaction due to the fact that it is not happening at a fast rate.
This then means that the glowing splint should not glow brightly because the test tube will
not have as much oxygen in it. However the potato that was placed at room temperature
should relight the glowing splint brightly and will produce a great amount of effervescence.
This is because enzymes work best at room temperature,due to this the catalase enzyme in the
potato should be able to break down more hydrogen peroxide into water and oxygen.Which
as said before will relight the glowing splint and produce a lot of effervescence.
Expected limitation:
The temperature at which the atmosphere is when the potato strip was left to sit at room
temperature is something that cannot be controlled. If the weather is cold or hot it is all
natural.
1. One could cut the length of the potato incorrectly which could affect the results seen.
2. One could measure the amount amount of hydrogen peroxide wrong which could