Scale parameters and functions

6.8 DR 7 interface parameters

Variable Note Type Length Read De- Min. Max. Modbus


(bytes) write fault Register
Assignment for Assignment for output 1: USHORT 2 rw 0 0 0xFFFF 1309
digital output 0-31: Status info
0, 1, 2, 3
33: Specified by S7 interface
(Page 89)
34: Reserved special code for de-
faults
100-131: Inverted status information
255: (Compatibility) output deac-
tivated
1000-1015: Operating error
1100-1115: Inverted operating error
2000-2047: Technological error
2100-2147: Inverted technological
error
3000-3047: Data or command error
3100-3147: Inverted data or com-
mand error
Assignment for output 1: USHORT 2 rw 0 0 0xFFFF 1310
(see Output 0)
Assignment for output 2: USHORT 2 rw 0 0 0xFFFF 1311
(see Output 0)
Assignment for output 3: USHORT 2 rw 0 0 0xFFFF 1312
(see Output 0)
Monitoring of Monitoring of the digital outputs and USHORT 2 rw 1 0 1 1313
the digital their supply voltage
outputs 0: Monitoring of outputs inactive
1: Monitoring of outputs active
Reaction of Reaction of the digital outputs to USHORT 2 rw 0 0 2 1314
the digital module fault or SIMATIC CPU stop:
outputs to fault 0: All outputs are switched off
or CPU stop
1: The corresponding predefined
(Page 89)
state value is applied
2: Outputs are not switched off,
work continues
3: All outputs are switched on
Reserve Reserve USHORT 2 rw 0 0 1 1315
Reserved USHORT 2 rw 0 0 1 1316
Replacement Predefined state of digital output DQ BIT 0 rw 0 0 1 1317.16
value for DQ 1 on error or SIMATIC CPU Stop
0, 1, 2, 3 Predefined state of digital output DQ BIT 0 rw 0 0 1 1317.15
(Page 89) 2 on error or SIMATIC CPU Stop
Predefined state of digital output DQ BIT 0 rw 0 0 1 1317.14
3 on error or SIMATIC CPU Stop
Predefined state of digital output DQ BIT 0 rw 0 0 1 1317.13
4 on error or SIMATIC CPU Stop

SIWAREX WP521/WP522
Manual, 04/2016, A5E36695225A 87