Manual SIWAREX WP521 WP522 en - PDF Page 59

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Commissioning

5.7 Commissioning with SIWATOOL

Unit of weight:
The unit of weight can be selected from a list.
Maximum weighing range:
Exceeding the maximum weighing range (= the maximum material to be weighed) is
indicated in DR30, status 1-2, at parameter "Max 9e".
If the maximum weighing range is exceeded, this bit is set to TRUE.
Resolution d:
The resolution d can be defined in accordance with EN 45501 (0.0001 to 50).
Once the above-mentioned parameters have been entered, the parameters modified in the
PC must be sent to the SIWAREX.
Service mode must be switched on first.
The DR3 and DR10 can only be sent and the calibration commands executed with service
mode switched on:

After switching on service mode, a red wrench icon is displayed in the SIWATOOL next to
the weight value:

The DR3 is subsequently sent to the SIWAREX by a right-click on "Calibration parameters


(DR3)" and execution of "Send data record":

SIWAREX WP521/WP522
Manual, 04/2016, A5E36695225A 59

You might also like