Datasheet 2MW

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Document No:

Technical Data Sheet for TDPS Generator


TDM-12-0975-R2

Basic Data Short circuit details:


Machine AC Generator Fault current in kA Initial Peak RMS
Make TD Power Systems Ltd. 3 Phase Fault -Sub-transient 33.72 11.92
Prime mover Diesel engine Line to Line fault - Sub-transient 24.94 8.82
Application Naval Marine Line to ground fault - Sub-transient 39.13 13.84
Duty Continuous Short circuit current withstanding capacity 300% for 10 secs
Non-Hazardous 3-phase short circuit Torque in kN-m 116.3
Area Classification
Marine 2-phase short circuit Torque in kN-m 126.9
Applicable Standard IRS / NAVAL / IEC
Over load withstanding capacity
Generator Details Stator over current capacity (Armature) 150% for 30 secs
Generator model TC125 Rotor over current capacity (Field) 125% for 60 secs
Mounting IM1101 (IM B20) Overload capability 110% for 1 hr in every 12 hr
Rating 2000 kWe / 2500 kVA
Rated Voltage 690 V +/-5% Excitation details
Rated Current 2092 A Excitation system type Brushless
Rated Frequency 50 Hz +/-2% Excitation supply Through PMG
Combined Voltage & Frequency Variation - R1 5% (Absolute) Exciter field current & voltage at No load 2 A & 29 V
Rated Speed 1000 rpm Exciter field current & voltage at full load 5.6 A & 80 V
Power factor 0.8 Main field current & voltage at full load 175 A & 143 V
Ambient temperature 55⁰ C
Altitude above MSL <1000 m PMG Details
Winding connection (no. of terminals for line/neutral) Star (3/floating neutral) Rating 3kVA
Insulation Class / Temp. Rise Class F / Class B Full load voltage 210V ±10%
Enclosure Protection - Main / Terminal box IP54 / IP54 Full load current 8.2A
Type of cooling CACW - IC817 Frequency 100Hz
Direction of rotation viewing from exciter side Counter clockwise
Rotor construction Cylindrical AVR Details
Bearing Type Antifriction Make & Type Basler & DECS 150
Lubrication Grease lubricated Voltage regulation with regulator ±1%
110 dB(A) + 5 dB(A)
Noise Limit - Air borne noise Response time < 50ms
tolerance
95 dB(A) to 131 dB(A) +
Noise Limit - Structure borne noise
5 dB(A) tolerance
Vibration Limit IEC 60034-14 Electrical parameters
Over speed 120% for 15mins Main stator resistance/Phase @25⁰ C 0.001 Ω
Total weight of AC Generator 13750 kgs Main rotor resistance @25⁰ C 0.673 Ω
Stator capacitance/Phase 0.086 µF
Efficiency in percentage (subjected to tolerance as per IEC)
%Load 0.8 p.f 1.0 p.f Mechanical Details
110% 95.7 96.9 DE End shield mounted
Bearing Mounting
100% 95.9 97.1 NDE End shield mounted
75% 95.9 96.9 Bearing life ≥40,000 hours
50% 95.3 96.1 Moment of inertia - GD² / GR2 1121 kgm² / 280.25 kgm²
25% 92.7 93.3 Inertia constant 0.61 s
Max. Cooling air inlet temp. 55⁰ C
Reactance's in percentage (subjected to tolerance as per IEC) Cooling Air Quantity 5.5 m³/s
Xd (sat/unsat) 181.8 / 206.6
Xd'(sat/unsat) 24.9 / 28.3 Accessories
Xd"(sat/unsat) 19.3 / 19.3 Winding RTD 6 No's (2 nos / phase)
X2(sat/unsat) 25.9 / 25.9 Bearing RTD 1 No. per bearing
X0(sat/unsat) 4.7 / 5.3 Space Heater-R2 4 x 150W, 1-Phase,230V
1 PT(3 phase) & 4 CT'S(Single
PTs & CTs
SCR pu 0.55 core)

Time constants in secs Additional Information's:


Tdo' 1.873 Protection against shaft currents NDE bearing insulated;
Tdo" 0.045 shaft earthing brush at DE
Td' 0.256 bearing
Td" 0.035 Terminal box location / Cable Entry -R2 Sides / Top
Ta 0.097 Parallel with other DGs and
Operational mode
Cooler details island
No. of cooler sections 1x100% TVD for Step Load of 100% kVA at Rated p.f 12.8 %
Cooling water inlet temperature/rise 40˚C/ Delta T:5˚C Voltage Recovery time <1.5 s
Cooling water quantity - R1 250 LPM Max Relative Humidity - R1 95% at 35°C
Double Tube Cooler material (Outer /Inner) - R1 Copper / CuNi 70/30 EMI / EMC - R1 IEC 61000
Tube Plate material (Water Side /Air Side) - R1 Ni Al Bronze / SS316L Shock Rating - R1 Vertical :4.7G, Lateral :1.0G, Longitudinal :0.4G
Water Box Material - R1 Ni Al Bronze Roll: Max 20° with 1 0 sec. Trim: Max 5°
Ship Motion - R1 List : Max 20° from vertical.
Cooling water type Sea water
Pitch : Max 6° with 20 sec.

All parameters given above are subjected to tolerance as per applicable standards.
NOTE:
Generator Complice to EED-Q-242 (R2) except deviation listed in EE/03/9712 Dtd: Nov-2020.

Prepared Checked Approved Date Rev Page No.


KN SSH HMS 13-10-2020 0 1 of 1

Revisions Reason for Revision Prepared Checked Date


R0 Initial Release KN SSH 13-10-2020
R1 Comments updated. SSH HMS 15-02-2021
R2 Details updated. SSH PMS 15-07-2021

You might also like