PLUMBING GENERAL NOTES MATERIAL SPECIFICATION

COLD/HOT WATER LINES PPR PIPES PN 20


1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED OR APPROVED EQUAL.
ACCORDING TO THE PROVISIONS OF THE PHILIPPINE PLUMBING DRAINAGE LINES 50Ø TO 100 Ø PVC PIPE
CODE, THE NATIONAL BUILDING CODE, AND THE RULES AND SERIES 1000,150 Ø & ABOVE
REGULATIONS OF THE CITY. NELTEX PVC PIPE CLASS 34
OR APPROVED EQUAL.
VENT / SEWER LINES 50Ø TO 100 Ø NELTEX PVC
2. COORDINATE THE DRAWINGS WITH OTHER RELATED DRAWINGS
PIPE SERIES 1000 OR EQUAL
AND SPECIFICATIONS THE ENGINEER SHALL BE NOTIFIED DOWNSPOUT 50 Ø TO 100 Ø NELTEX PIPE
IMMEDIATELY OF ANY DISCREPANCY FOUND THEREIN. SERIES 1000 OR APPROVED
EQUAL.
3. ALL PIPES SHALL BE INSTALLED AS INDICATED, ANY RELOCATION WATER METER TOYO OR ASAHI MODEL OR
REQUIRED FOR PROPER EXECUTION OF OTHER TRADE SHALL BE MWSS APPROVED
GATE VALVES KITZ, CRANE , PPR GV OR APPROVED EQUAL.
WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
4 DETAIL OF AIR CHAMBER
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL P 1
Scale NTS
LOCATION, DEPTH AND INVERT ELEVATIONS OF EXISTING PIPES
AND STRUCTURES AS VERIFIED BY THE CONTRACTOR.
5. ALL SEWER LINES SHALL BE PVC PIPES.
6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1%
MINIMUM UNLESS OTHERWISE SPECIFIED.
7. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN
ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS. DETAIL OF FLOOR DRAIN
2 DETAIL OF GUTTER DRAIN/
(BASKET STRAINER)
P 1
Scale NTS
8. ALL WATER LINES SHALL BE pprc PIPE. 3
P 1
Scale NTS
9. ALL DOWNSPOUT SHALL BE PVC PIPES.
10. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE
AND COORDINATE THE WORKS WITH THE SEWER LINES EFFLUENT
DISPOSAL AND WATERLINE SERVICES CONNECTION POINT.
LEGEND
SP SOIL PIPE
DP DRAINAGE PIPE
FCO FLOOR CLEAN OUT
CO CLEAN OUT
DS DOWNSPOUT
VSTR VENT STACK THRU ROOF
1 DETAIL OF SEPTIC TANK
SS SOIL STACK P 1
Scale NTS
VS VENT STACK
VP VENT PIPE 8 DETAIL OF HOSE BIBB
CWL COLD WATER LINE P 1
Scale NTS
CWR COLD WATER RISER
GV GATE VALVE
CV CHECK VALVE
HB HOSE BIBB
WM WATER METER
FD FLOOR DRAIN
CB CATCH BASIN
WC WATER CLOSET
KS KITCHEN SINK
LAV LAVATORY
F FAUCET
FB FOOT BATH
GCO GROUND CLEAN OUT
WS WASTE STACK
SHO SHOWER
AD AREA DRAIN
6 DETAIL OF CLEAN-OUT 7 DETAIL OF CATCH BASIN 9 DETAIL OF FCU DRAIN
1
P 1
Scale NTS P 1
Scale NTS
P Scale NTS
DETAIL OF TRENCHING,
5 BEDDING & BACKFILLING
P 1
Scale NTS
Drawings and Specifications duly signed, stamped
or sealed, as instruments of service are the
intellectual properties and documents of the
PLUMBING GENERAL NOTES
ENGINEER / ARCHITECT , whether DETAIL OF SEPTIC TANK P-1
the object for which they are made is executed or
PROPOSED SINGLE STOREY RESIDENTIAL BLDG DETAIL OF FLOOR DRAIN
MRS. ALICE EBAL
not. It shall be unlawful for any person, without the
SANITARY ENGINEER consent of the ENGINEER / ARCHITECT DETAIL OF GUTTER DRAIN
or author of said documents, to duplicate or to
make copies of said documents for use in the DETAIL OF TRENCHING, BEDDING AND BACKFILLING
repetition of and for other projects or buildings,
DETAIL OF CLEAN-OUT
12 / 14
whether executed partly or in whole.
BRGY. MALABON, CANDELARIA, ZAMBALES DETAIL OF CATCH BASIN
DETAIL OF FCU DRAIN