Professional Documents
Culture Documents
Instrument Tranformers
Instrument Tranformers
Page VII.VII-1
1.0 Manufacturer
1.1 Type - -
1.2 Model no - -
1.3 Country of Origin - -
Equipment that
are compliant
with KEMA,
KERRI or CESSI
Certifications
Only.
(Attach
Certificates and
Type Tests
report from STL
Members only)
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-2
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-3
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-4
1.0 Manufacturer -
Equipment that
are compliant
with KEMA,
KERRI or CESSI
Certifications
Only.
(Attach
Certificates)
1.1 Type - -
1.2 Model no - -
2.0 Nominal characteristics
2.1 Voltage
2.1.1 Rated voltage kV 132
2.1.2 Rated voltage class kV 145
2.2 Rated frequency Hz 50
2.3 Network neutral grounding - Effective
2.4 Rated voltage factor for 30 s - 1,5
2.5 Rated lightning impulse withstand kV 650
2.6 Power frequency withstand voltage (1 min) kV 275
2.7 Creepage distance mm/kV 31
2.8 Capacitance C1 and C2 pf 8800
2.9 Series reactor
- inductance range mH 0.2
- resistance range ohms -
2.10 Transformation ratio - 132kV/3
: 0,11kV/3
: 0,11kV/3
(: 0,11kV/3)
2.11 Transformer characteristics
- HV/LV turn ratio range - -
- Normal operating flux density tesla -
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-5
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-6
1.0 Manufacturer -
Equipment that are
compliant with
KEMA, KERRI or
CESSI Certifications
Only.
(Attach Certificates
and Type Tests
report from STL
Members only)
1.1 Type - Oil
1.2 Model no - -
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-7
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-8
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-9
1.0 Manufacturer -
Equipment that are
compliant with
KEMA, KERRI or
CESSI Certifications
Only.
(Attach Certificates)
1.1 Type - Oil
1.2 Model no - -
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-10
-Burden 20 VA
-ISF ≤5
- Core No. 2 & 3 (Protection) - (5P20)
- Core No.4 Class X
- burden - 20 VA
-Knee point Volts(Vk) 30(Rct+36):core 2&3
40(Rct+7):core 4
2.14 Winding conductor - Cu
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-11
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-12
1.0 Manufacturer -
1.1 Type - -
1.2 Model no - -
1.3 Country of origin - -
Equipment that
are compliant
with KEMA,
KERRI, CESSI or
any other
member of STL
group
Certifications.
(Attach
Certificates)
2.0 Nominal characteristics
2.1 Voltage
2.1.1 Rated voltage kV 33
2.1.2 Rated maximum voltage class kV 36
2.2 Rated frequency Hz 50
2.3 Network neutral grounding - Effective
2.4 Rated voltage factor for 30 s - 1,5
2.5 Rated lightning impulse withstand kV 170
2.6 Power frequency withstand voltage (1 min) kV 70
2.7 Creepage distance mm/kV 31
2.8 Design - Inductive
2.9 Transformation ratio: - 33kV/3
: 0,11kV/3
: 0,11kV/3
2.10 Transformer characteristics
- HV/LV turn ratio range - -
- Normal operating flux density tesla -
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-13
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-14
1.0 Manufacturer -
1.2 Model no - -
1.3 Country of origin - -
Equipment that are
compliant with
KEMA, KERRI, CESSI
or any other
member of STL
group Certifications.
(Attach Certificates)
2.0 Nominal characteristics
2.1 Voltage
2.1.1 Rated max. operating voltage kV 33
2.1.2 Rated voltage class KV 36
2.2 Rated frequency Hz 50
2.3 Network neutral grounding - effective
2.4 Heating limit at maximum ambient C 55
temperature
2.5 Rated current A 400/600/800/1200
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-15
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-16
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE
TRANSMISSION COMPANY OF NIGERIA (TCN).
Technical Specifications – Instrument Transformers
Page VII.VII-17
DOCUMENT TS 4130 REV. 2 TCN (SUPPLY OF EQUIPMENT & MATERIALS) FOR 2015-2016
GRID MAINTENANCE