Hottapping Dimension & Field Requirements


To avoid problems and/or expensive delays, Consult WIC Spore for confirmation and the following information must
be forwarded to those people in the field directly involved with this work.

Equipment Dimensions:
S/N SIZE A B SIZE OF WEIGHT MAX LENGTH (C) MACHINE USED
(INCH) CUTTER (KG) 150# 300# 600#
1 <2 55 55 1-7/16 15 11 12 15 1 LEGEND :
2 3 55 55 2/7/16 15 12 16 19 0 3 AIR OPT
3 4 75 120 3-7/16 410 14 17 23 1 6 HYD OPT
4 6 80 125 5-15/32 440 16 22 29 0 6
5 8 82 127 7-5/16 450 18 23 34 6 7
6 10 98 170 9-1/2 460 20 25 40 0 6
7 12 98 170 11-1/2 520 21 28 42 0
8 14 98 170 12-3/4 1845 23 39 45 1
9 16 135 240 14-11/16 1915 24 42 49 2
10 18 135 240 15-1/16 2015 25 46 54 0
11 20 135 240 17 2100 27 49 58 0
12 24 135 240 21 2190 30 56 67

Machine Specification :
Overall length without T/M adapter :
- T101 T/M ( Air Operated) : 50”
- 360 T/M (Air Operated ) : 48” W/O measuring rod , 70” W/ ith measuring rod
- 660 T/M (Air / Hydraulic Operated ) : 70” without measuring rod
111” with measuring rod
- 760 T/M ( Hydraulic Operated ) : 95” without measuring rod
111” with measuring rod

Minimum Air supply ( F/ Air operated machine only) : 120 PSI W/ 105 CFM

NOTE: - All dimension in inches .


- Dimensions will vary if spool adapter are required – Provide adequate clearance and consult WIC.
- Verification of machine capability are required for all hottapping using 360 T/M and subject to review by WIC.
- Dimension stated based on standard wall thickness, RFWN weldolets or hottap fittings and standard isolation
valve
- All dimension are based on Standard Hottaps onto Carbon Steel Nominal Size pipe ; 90 DEGREE to pipe ,
free from lamination. Any spiral wound pipe must be informed to WIC.

FULL BORE TAPPING FITTING


ISOLATION VALVE

C
TAPPING
MACHINE