Professional Documents
Culture Documents
How To Setup A Hyosung PCI 3.0 (8000 Series) Keypad
How To Setup A Hyosung PCI 3.0 (8000 Series) Keypad
How To Setup A Hyosung PCI 3.0 (8000 Series) Keypad
0 (8000
series) Keypad
• After physically installing the new EPP Keypad on the ATM, you must perform a series of
steps to set the EPP to the "Installation State" so that you can enter encryption "keys" on the
terminal.
• The Key Management passwords that you are familiar with (000000 / 000000) are now set to
the following defaults (111111 / 222222).
• There are also an additional set of IDs and Passwords that you must enter in order to access
the software to allow you to configure the "state" of the EPP. These values are (111111 /
111111) and (222222 / 222222). Please enter these when prompted during the setup
procedures. (If you perform a keypad reset, then these passwords will default to
000000/000000 and will need to be changed prior to accessing the “Set EPP State” function)
• When installing the new PCI 3.0 EPP on a SE Style ATM, it will have to have an Application version
of 06.01.07 or higher to support this new EPP
4) At the SECURE MODE screen, input the KEY MANAGEMENT PASSWORD #1 (111111).
8) Enter the factory default Account 1 ID and PASSWORD (111111 and 111111)
9) Next, enter the factory default Account 2 ID and PASSWORD (222222 and 222222)
• Initialization State
• Authorized Removal State
• Installation State
• Unauthorized Removal State
The EPP should be in the INITIALIZATION STATE. If so, continue at Step 12 below.
If the EPP is in the AUTHORIZED REMOVAL STATE, also continue at Step 12 below.
If the EPP is in the UNAUTHORIZED REMOVAL STATE, a problem may have occurred
during shipment. You will need to perform a NVRAM Clear on the EPP. (NOTE: This is
different than the ATM CLEAR NVRAM function). Go to Appendix A.
12) Select CHANGE STATE. The ATM will prompt you to change the state from
INITIALIZATION STATE to INSTALLATION STATE (or from AUTHORIZED REMOVAL
STATE to INSTALLATION STATE).
15) Press CANCEL four times to return to the Operation Program screen. PCI 3.0 EPP setup is
complete.