Professional Documents
Culture Documents
Vacon X Series Brochure
Vacon X Series Brochure
vacon x series
®
71
t2
t1
t0
Robust Enclosure The VACON X Series features a best in class • Reduced Installation Cost
UL Type 4X, Indoor/Outdoor certified enclosure • High Reliability
through 100HP
Integrated Brake Resistor Each VACON X Series includes a Brake resistor • Reduced Installation Costs
allowing it to better handle high inertial loads • Mount in Low Temperatures
and warm up in cold conditions
Built-in Sequencer The VACON X Series features a built-in multi- • Reduced investment costs
step sequencer that can replace a small PLC • Flexible application programming
in many applications
73
standard vacon x series features
toughest packaging
• Thick injected foam and metal covers protect against bumps and
misuse
• Withstands 1,000 PSI washdown from 6 inches away on models
though 30 HP
• Withstands 1000 PSI washdown from 12 inches away on models
through 100HP
• Mounts close to the motor to eliminate long motor lead problems
indoor or outdoor
easy to use
versatile programming
Not only does the VACON X Series feature a robust and reliable
x series
vacon ®
real-time clock
75
x-series i/o
product range
vacon x series 115 vac 1-ph
Product Code Motor Shaft Power and Current Dimensions
Frame Weight (kg)
High Overload (150%) Low Overload (120%) W x H x D (mm)
Vacon X4 Vacon X5 Size Weight (lbs)
HP kW Amps HP kW Amps W x H x D (in)
221 x 306 x 216 6.35
--- VACONX5C1S010C 0.5 0.37 2.2 1 0.75 4.2 T1A
8.72 x 12.01 x 8.49 14
165 x 241 x 155 3.85
VACONX4C1S010C VACONX5C1S010C09 0.5 0.37 2.2 1 0.75 4.2 T0
6.5 x 9.47 x 6.08 8.5
76
product range
vacon x5 c 4 0500 c
77
vacon x series options
OPTION ORDER TYPECODE NOTE
DeviceNet Option Card X5DNET01
ModBus TCP/IP Option Card X5MBTCP01 VACON X5 Only. Models with “09” suffix will not accept option cards
ProfiBus Option Card X5PROF01
Remote Keypad for Wall Mount Drives XRKWM VACON X4 and X5 - Frames 0-2
Control Features At start, stop, by frequency with adjustable current level and time or continuous DC injection by
DC holding/injection braking
digital input
Current limit Four-quadrant adjustable from 5 to 150%
Speed ramps Primary and alternate adjustable from 0.1 to 3200.0 seconds
Voltage boost Adjustable fixed boost or adjustable auto boost
Voltage characteristic V/Hz - Linear, pump, fan or 2-piece linear; Sensorless Vector
Timed overload Adjustable inverse time trip (shear pin, 30 sec, 60 sec, 5 minutes) for standard or inverter-duty motors
Overcurrent, Overvoltage fault, ground fault, short circuit, Dynamic Brake overload, drive tempera-
x series
Protective features
vacon ®
ture, power wiring fault. Drive-timed overload, input voltage quality, overvoltage ridethrough
X4: 9-step, PLC-type functionality to control speed, direction and ramp times based on time,
analog input, digital input or pulse count.
Program Sequence Controller X5: 25-step, PLC-type functionality that can control speed, direction and ramps based on time,
analog input,digital input, or pulse input. Conditional branching, addressable outputs and real time
operations possible.
X4: PI Process control available with the use of a customer supplied transducer, either 0-10Vdc,
4-20mA or optical encoder input to the drive.
PI and PID Feedback X5: Process control available with the use of a customer supplied transducer, either 0-10Vdc,
4-20mA or optical encoder input to the drive. Includes an optional sleep mode, activated when the
loop is satisfied.
78
WE ARE DRIVES
vacon x5 hazlo
®
79
designed for the real world
The new VACON X5 HazLo is a first in the world of AC Drives. Designed as an out of
the box solution, the VACON X5 HazLo builds on the very foundations of a world class
harsh duty drive to create a unique solution for Hazardous Locations. The VACON X5
HazLo has been certified for Class I, II and III; Division 2 locations suitable for several
applications in Refineries, Graineries, Gypsum Processing Facilites or anywhere else where
ignitable substances are not normally present, but may exist in unlikely scenarios.*
Built-in Sequencer Features a built-in multi-step sequencer that can replace a • Reduced investment costs
small PLC in many applications. • Flexible application programming
Standards UL - ANSI/ISA 12.12.01, 2007, cUL - CAN/CSA C22.2 No. 157-M1987, CAN/CSA C22.2 No. 157
x5 hazlo
vacon ®
80 WARNING: VACON® X5 HazLo© should only be applied in approved hazardous locations. Check the User Manual for specific classifications.
vacon ® x5 hazl o © approved hazardous locations
Classes Groups Division 2
I: Gasses, vapors and A: Acetylene Not normally present in an explosive
liquids B: Hydrogen, etc. concentration (but may accidentally exist)
C: Ether, etc.
D: Hydrocarbons, fuels, solvents, etc.
II: Dusts F: Carbon dusts (some are conductive and Dust not normally suspended in an ignitable
all are explosive) concentration (but may accidentally exist). Dust
G: Flour, starch, grain, combustable plastic layers are present.
or chemical
III: Fibers and flyings Textiles, wood-working, etc. (easily Stored or handled in storage (exclusive of
ignitable, but not likely to be explosive) manufacturing)
Source: OSHA.gov
VACON® X5 HazLo© AC Drives are ideal for a variety of applications such as:
Applications in Class 1, Div 2 locations:
• Petroleum refineries, and gasoline storage and dispensing areas.
• Dry cleaning plants where vapors from cleaning fluids can be present.
• Spray finishing areas.
• Aircraft hangars and fuel servicing areas.
• Utility gas plants and operations involving storage and handling of liquefied petroleum gas or natural gas.
• Water and wastewater facilities.
Applications in Class 2 and Class 3, Div 2 locations:
• Grain elevators; flour and feed mills.
• Producers of plastics, medicines and fireworks.
• Producers of starch or candies.
• Spice-grinding plants, sugar plants and cocoa plants.
• Coal preparation plants and other carbon handling or processing areas.
• Textile mills, cotton gins; cotton seed mills, flax processing plants and plants that shape,
pulverize or cut wood and create sawdust.
Source: OSHA.gov
x5 hazlo
vacon ®
WARNING: VACON® X5 HazLo© should only be applied in approved hazardous locations. Check the User Manual for specific classifications. 81
x5 hazlo i/o
product range
vacon x5 hazlo 480v 3-ph
Motor Shaft Power and Current Dimensions
Product Code Frame Weight (kg)
High Overload (150%) Low Overload (120%) W x H x D (mm)
Size Weight (lbs)
Safety Yellow Stainless Steel HP kW Amps HP kW Amps W x H x D (in)
VACONX5C40400X VACONX5C40400Y 30 22 40 40 30 52 286 x 513 x 314 22.68
T3
VACONX5C40500X VACONX5C40500Y 40 30 52 50 37 65 11.19 x 20.19 x 11.73 50
VACONX5C40600X VACONX5C40600Y 50 37 65 60 45 77
326 x 745 x 351 43.1
VACONX5C40750X VACONX5C40750Y 60 45 77 75 55 96 T4
12.84 x 29.35 x 13.8 95
VACONX5C41000X VACONX5C41000Y 75 55 96 100 75 124
82 WARNING: VACON® X5 HazLo© should only be applied in approved hazardous locations. Check the User Manual for specific classifications.
vacon x5 hazlo options
OPTION ORDER TYPECODE NOTE
DeviceNet Option Card X5DNET01X Must include the “X” suffix for the VACON X5 HazLo
ModBus TCP/IP Option Card X5MBTCP01X
Control Features At start, stop, by frequency with adjustable current level and time or continuous DC injection by
DC holding/injection braking
digital input
Current limit Four-quadrant adjustable from 5 to 150%
Speed ramps Primary and alternate adjustable from 0.1 to 3200.0 seconds
Voltage boost Adjustable fixed boost or adjustable auto boost
Voltage characteristic V/Hz - Linear, pump, fan or 2-piece linear; Sensorless Vector
Timed overload Adjustable inverse time trip (shear pin, 30 sec, 60 sec, 5 minutes) for standard or inverter-duty motors
Overcurrent, Overvoltage fault, ground fault, short circuit, Dynamic Brake overload, drive tempera-
Protective features
ture, power wiring fault. Drive-timed overload, input voltage quality, overvoltage ridethrough
X4: 9-step, PLC-type functionality to control speed, direction and ramp times based on time,
analog input, digital input or pulse count.
Program Sequence Controller X5: 25-step, PLC-type functionality that can control speed, direction and ramps based on time,
analog input,digital input, or pulse input. Conditional branching, addressable outputs and real time
operations possible.
X4: PI Process control available with the use of a customer supplied transducer, either 0-10Vdc,
4-20mA or optical encoder input to the drive.
PI and PID Feedback X5: Process control available with the use of a customer supplied transducer, either 0-10Vdc,
4-20mA or optical encoder input to the drive. Includes an optional sleep mode, activated when the
loop is satisfied.
x5 hazlo
vacon ®
WARNING: VACON® X5 HazLo© should only be applied in approved hazardous locations. Check the User Manual for specific classifications. 83
84