Atellica® 1500 Automated Urinalysis Analyzer

Pageavailable
*Not
Training Workbook
1 for sale in the U.S. Product availability varies by country.
HOOD05162002985708 Effective date: 2/2/2019
Table of Contents
Hardware Overview……………………….…….….. 3

Software Overview……………………………….….. 10

Routine Operations

Daily Maintenance.….…………………………. 14

System Preparation.……..………………….…. 24

Sample Processing………….……………..……. 32

Reviewing Results................................... 33

Printing Results....................................... 36

Calibration (CLINITEK Novus® Analyzer)...... 39

Quality Control….......................................... 42

Maintenance………………………………….………… 47

Monthly Maintenance................................. 49

Periodic Maintenance................................ 51

Database Backup......................................... 53

© Siemens
Page 2 AG 2013. All rights reserved.
Hardware Overview – Atellica® 1500 Analyzer
Atellica® 1500 Automated Urinalysis Analyzer is composed of:
1. Atellica® UAS 800 Analyzer
2. CLINITEK Novus® Automated Urine Chemistry Analyzer
3. Sample rack handler
2
1

Hardware Overview
© Siemens
Page 3 AG 2013. All rights reserved.
Hardware Overview – Atellica® UAS 800 Analyzer
3
Atellica® UAS 800 Analyzer External Components
1. Sample rack handler
• Up to 10 racks can be loaded
2. Sampling area 7
• Samples are mixed and aspirated
5 2
3. Cuvette waste bin
• Holds used cuvette cartridges 6 1
4. Wash and waste bottles
• Utilized for cleaning of the analyzer
5. On/off button (on left side of analyzer)
4
6. PC, monitor, keyboard, mouse (PC not shown)
• Used to navigate the software
7. Serial number (on back of instrument, not shown)

© Siemens
Page 4 AG 2013. All rights reserved.
Hardware Overview – Atellica® UAS 800 Analyzer
Atellica® UAS 800 Analyzer Internal Components
Cuvette carousel
• holds up to 12 cuvette cartridges, each contains up to
50 cuvettes

Not visible in this image:


Pipette
• Used to mix, aspirate and dispense urine sample
Front and rear cuvette guides
• Used to transport cuvette Cuvette
carousel
Centrifuge
• Spins cuvette to bank the particles on one plane
Microscope and high-resolution camera
• Used to analyze the urine sample

© Siemens
Page 5 AG 2013. All rights reserved.
Hardware Overview – CLINITEK Novus® Analyzer
CLINITEK Novus® Automated Urine Chemistry Analyzer
External Components
1. Sample rack handler
• Up to 10 racks can be loaded
2. Display
• Used to navigate the software 2
3
3. Sampling area 5
• Aspirates urine sample
• Barcode reader 4 6
4. Card waste drawer 1
• Holds used cards
5. Waste bottle
6. Rinse bottle
7. On button (on side of instrument, not shown)
8. Serial number (on back of instrument, not shown)

© Siemens
Page 6 AG 2013. All rights reserved.
Hardware Overview – CLINITEK Novus® Analyzer
CLINITEK Novus® Automated Urine Chemistry Analyzer
Internal Components
1. Pipette (not shown)
• Dispenses urine sample on test pads and into SG well
2. Cassette compartment door
• Holds a reagent cassette and keeps it away from
moisture
3. Card Platform 4
• Holds test card during processing
4. Syringe
• Aspirates and dispenses urine sample through pipette 2
3
5. SG well (not shown)
• Used to measure specific gravity and report clarity
6. Color camera and LED lights (not shown)
• To take images of test pads for analysis

© Siemens
Page 7 AG 2013. All rights reserved.
Hardware Overview
Hardware Overview
Review Questions
Review Questions
1. Where are the instrument serial numbers located?

2. How many racks can be loaded onto the Atellica® 1500 Analyzer?

3. Which instrument uses cuvettes?

4. What is the function of the SG well on the CLINITEK Novus® Analyzer?

© Siemens
Page 8 AG 2013. All rights reserved.
Software Overview
Hardware Overview
Review Questions
Review Questions Answer Key

1. On the back of each instrument.

2. 10

3. Atellica® UAS 800

4. Measure specific gravity and report clarity

© Siemens
Page 9 AG 2013. All rights reserved.
Software Overview – Atellica® UAS 800 Analyzer
1
Atellica® UAS 800 Analyzer Screen Overview
2
1. Title bar
• Displays device name and software version
2. Menu bar
• Displays icons used to perform a task, including Shut
Down and Logout 3
3. Workspace
• Displays information and messages for the current task
4. System Function bar
• Used to perform actions on the current screen
5. Status bar
• Displays task and system indicators
4

10

© Siemens
Software Overview
Page 10 AG 2013. All rights reserved.
Software Overview – CLINITEK Novus® Analyzer
1
CLINITEK Novus® Analyzer Screen Overview
2
1. Status bar
• Displays system status indicators
3 7
2. Title bar
• Displays current screen name, date, and time
3. Cassette Status
• Displays status of loaded cassette
4. Off button
• Shuts down software and powers down hardware
5. Navigation bar 8
• Displays task and system indicators
6. System function bar 4
• Displays menus to complete tasks
7. Status log
• Displays system messages
8. System indicators 5 6
• Displays status of waste and rinse
11

© Siemens
Software Overview
Page 11 AG 2013. All rights reserved.
Hardware Overview
Software Overview
Review Questions
Review Questions

1. What area of the system software on both analyzers displays system status information?

2. On both analyzers, where is the Shut Down button located?

3. On the Atellica® UAS800 analyzer, which icon do you select to switch users?

12

© Siemens
Page 12 AG 2013. All rights reserved.
Software Overview
Software Overview
Review Questions
Review Questions Answer Key

1. Status bar

2. Right side of Menu bar for Atellica® UAS 800, Left side of screen above Navigation bar for CLINITEK Novus® Analyzer.

3. Logout in the Menu bar

13

© Siemens
Page 13 AG 2013. All rights reserved.
Daily Maintenance – Atellica® UAS 800 Analyzer
Empty and clean the cuvette waste bin Clean the sample rack handler
1. Remove the cuvette waste bin. 1. Wipe the sample rack handler with a cloth moistened with a
1:10 bleach solution.
2. Empty cuvette waste bin according to your facility’s disposal guidelines.
2. Wipe the sample rack handler with water and dry.
3. Clean the cuvette waste bin with 1:10 solution of bleach.
4. Rinse with water and dry.
5. Replace the cuvette waste bin.
Note: The cuvette counter resets to 0 when it is replaced.

UAS 800 rack handler

14
Daily
© Siemens Maintenance
Page 14 AG 2013. All rights reserved.
Daily Maintenance – Atellica® UAS 800 Analyzer
Clean the front cuvette guide
1. Open the front cover.
2. Remove the front cuvette guide holding it at a slight angle to avoid
bumping the cuvette carousel.
3. Wipe the guide with 70% isopropyl alcohol.
4. Wipe the guide with water and dry.
5. Clean the supporting plate and the pins where the guide is installed with
a cloth moistened with 70% isopropyl alcohol.
6. Replace the front cuvette guide at a slight angle. Align the holes on the
guide with the supporting pins. Confirm there is no gap when the guide
is seated on the supporting pins.
7. Close the front cover.

15
Daily
© Siemens Maintenance
Page 15 AG 2013. All rights reserved.
Daily Maintenance – Atellica® UAS 800 Analyzer
Clean the rear cuvette guide
2
1. Open the front cover.
2. Turn the microscope arm toward the front of the analyzer. Do not
remove the securing screw.
3. Hold the rear cuvette guide at a slight angle and remove it from the
analyzer.
4. Wipe the guide with 70% isopropyl alcohol, wipe with water and dry.
5. Clean the supporting plate and the pins where the guide is installed with
a cloth moistened with 70% isopropyl alcohol.
6. Replace the rear cuvette guide at a slight angle. Align the holes on the
guide with the supporting pins in the analyzer.
7. Turn the microscope arm back to its original location.
8. Close the front cover.

16

© Siemens
Page 16 AG 2013. All rights reserved.
Daily Maintenance – Atellica® UAS 800 Analyzer
Check the washing liquid bottle
1. Check the washing liquid bottle level in the status bar or by visual
inspection.
2. Refill the bottle if it is almost empty. Do not perform this task when the
analyzer is running.
3. Remove the cap with attached sensor and place it on a clean surface.
4. Fill the bottle with deionized water.
5. Replace the cap on the bottle.
Note:
Ensure the tubing is inserted into the cap until the “Push
Until” label on the tubing is almost covered.

17

© Siemens
Page 17 AG 2013. All rights reserved.
Daily Maintenance – Atellica® UAS 800 Analyzer
Empty and clean the waste water bottle
1. Check the waste water bottle level in the status bar or by visual
inspection.
2. Remove the cap with attached sensor.
3. Empty the bottle according to the lab’s waste disposal guidelines.
4. Clean the bottle with a 1:10 solution of bleach.
5. Replace the cap with attached sensor.

Note:
Allowing the floater to stay in contact with the tubes inside
the bottle could result in an erroneous waste status.

18

© Siemens
Page 18 AG 2013. All rights reserved.
Daily Maintenance – Atellica® UAS 800 Analyzer
Perform daily disinfecting rinse
1. Confirm the analyzer is in the Online status.
2. Remove all racks from the rack handler. 5
3. Pour 6 mL of 2% bleach solution into a test tube. Place the test tube in
Position 1 of an empty rack.
4. Select the Shut Down button on the software.
5. Select the check to confirm you want to shut down the analyzer.
6. Select the check to confirm you want to start the procedure.
6
7. Open the front cover.
8. Remove the front cuvette guide holding it at a slight angle to avoid
bumping the cuvette carousel.
9. Close the front cover and select the check to start the rinse.
10. After the disinfecting rinse is finished and the instrument is powered off
automatically, replace the front cuvette guide at a slight angle. Align the 9
holes on the guide with the supporting pin.
11. Close the front cover.
19

© Siemens
Page 19 AG 2013. All rights reserved.
Daily Maintenance – CLINITEK Novus® Analyzer
Clean the SG well
1. Pour at least 2 mL of 5.25% sodium hypochlorite into a tube labeled
Bleach.
2. Place the tube into the first position of a sample rack.
3. Load the rack onto the system.
4. Select System.
5. Select Clean SG Well.
6. Select Start.

Clean the sample rack handler


1. Use a germicidal wipe to clean the sample rack handler.

20

© Siemens
Page 20 AG 2013. All rights reserved.
Daily Maintenance – CLINITEK Novus® Analyzer
Empty the waste bottle (External bottle) Empty the waste bottle (Internal bottle)
1. Disconnect the tubing from the bottle. 1. Remove racks from the sample rack handler.
2. Empty the waste according to your facility’s disposal guidelines. 2. Press the latch and pull the waste bottle drawer out of the
slot.
3. Reconnect the tubing.
3. Turn the bottle cap counterclockwise and remove it.
4. Empty the waste according to your facility’s disposal
guidelines.
5. Replace the cap and turn it clockwise, finger tight.
6. Wipe off any spillage on the bottle.
7. Slide the waste bottle drawer into the slot until it is
latched.

21

© Siemens
Page 21 AG 2013. All rights reserved.
Hardware Overview
Daily Maintenance
Review Questions
Review Questions
1. On the Atellica® UAS 800 analyzer, where do you check the status of the waste water bottle and washing liquid bottle?

2. What cleaning solution is used to clean the front and rear cuvette guides on the Atellica® UAS 800 analyzer?

3. What concentration of sodium hypochlorite is used in the cleaning of the CLINITEK Novus® SG well?

22

© Siemens
Page 22 AG 2013. All rights reserved.
Software Overview
Daily Maintenance
Review Questions
Review Questions Answer Key

1. Status bar

2. 70% isopropyl alcohol

3. 5.25%

23

© Siemens
Page 23 AG 2013. All rights reserved.
System Preparation – Atellica® UAS 800 Analyzer
Logging on
1. Press the power button on the analyzer.
2. Turn on the personal computer (PC).
3. When the dialog box appears, type in login name and
password.
4. Select OK.

Logging off
1. Select Logout in the Menu bar.

24
System
© Siemens
Page 24 AG 2013. All rights reserved. Preparation
System Preparation – Atellica® UAS 800 Analyzer
Loading cuvettes
1. Open the front cover.
2. Rotate wing screw to the left on top of cuvette carousel.
3. Lift and remove top of cuvette carousel.
4. Open cuvettes carton and remove registration card.
5. Load a single cuvette cartridge into the carousel. Image of cuvettes carton
6. Turn the carousel clockwise to the next empty slot.
7. Load cuvette cartridges until the carousel is full.
8. Replace top on carousel and tighten wing screw.
9. Remove tape at the bottom of each cuvette cartridge.
10. Close the front cover.

Note:
Cuvettes must be registered with the system before processing samples.
25

© Siemens
Page 25 AG 2013. All rights reserved.
System Preparation – Atellica® UAS 800 Analyzer
Registering cuvettes
1. Select the Measure icon.
2. Select the Cuvette Reg button.
3. Press the check.
4. Insert the registration card in the sampling area with barcode
facing the reader.
3
5. Select the check to return to the Measure screen.

5
26

© Siemens
Page 26 AG 2013. All rights reserved.
System Preparation – CLINITEK Novus® Analyzer
Loading reagent cassette
1. Select System.
2. Select Load & Unload.
3. Select Yes.
4. Open the front cover.
5. Unlock and open the cassette door.
6. Remove the cassette.
7. Load the new cassette.
8. Close and lock the cassette door.
9. Close the front cover.

Note:
The system reads the lot number and expiration date of the
reagent cassette when the front cover is closed.

27

© Siemens
Page 27 AG 2013. All rights reserved.
System Preparation – CLINITEK Novus® Analyzer
Empty and fill rinse bottle
1. Remove racks from the sample rack handler.
2. Press the latch forward and pull the rinse drawer out of the slot.
3. Turn the bottle cap counter clockwise to remove it.
4. Empty the rinse solution according to your facility’s disposal
guidelines.
5. Fill the rinse bottle with 1000 mL of distilled or deionized water.
6. Add 2 mL of CLINITEK Novus Rinse Additive.
7. Gently swirl the bottle six times.
8. Replace the cap and turn it clockwise, finger tight.
9. Slide the rinse drawer into the slot until it is latched.
10. Select System.
11. Select Prime Pump.

28

© Siemens
Page 28 AG 2013. All rights reserved.
System Preparation – CLINITEK Novus® Analyzer
Empty card waste drawer
1. Remove racks from the sample rack handler.
2. Press the latch forward and pull the card waste drawer out of the
slot.
3. Empty the cards according to your facility’s disposal guidelines.
4. Remove and clean the internal liner with isopropyl alcohol.
5. Replace the internal liner.
6. Slide the card waste drawer into the slot until it is latched.

29

© Siemens
Page 29 AG 2013. All rights reserved.
Hardware Overview
System Preparation
Review Questions
Review Questions

1. After loading cuvettes onto the Atellica® UAS 800 analyzer, which screen do you need to access to register cuvettes?

2. On the CLINITEK Novus® analyzer, which screen provides access to the Load & Unload button for loading reagent
cassettes?

3. Which task must be performed after filling the rinse bottle on the CLINITEK Novus® analyzer?

30

© Siemens
Page 30 AG 2013. All rights reserved.
Software Overview
System Preparation
Review Questions
Review Questions Answer Key

1. Measure screen

2. System screen

3. Prime pump

31

© Siemens
Page 31 AG 2013. All rights reserved.
Sample Processing – Atellica® 1500 Analyzer
Loading barcoded sample tubes
1. Place sample into the rack starting with position 1.
2. Tilt the rack at an angle to the right, align the rack slot with
the retaining rail and load on the CLINITEK Novus® Analyzer
sample rack handler. Ensure the barcodes are facing the
system.
3. Select Start on the CLINITEK Novus screen.
When sampling on the CLINITEK Novus Analyzer is complete, the
rack moves along the sample rack handler to the Atellica® UAS
800 Analyzer.

Note: The minimum volume required to run the sample on


both systems is 2.6 mL
Samples to avoid for CLINITEK Novus® analyzer: visibly
bloody, mucoid or foamy samples
Samples to avoid for Atellica® UAS 800 analyzer: foamy
samples
32
Sample
© Siemens
Page 32 AG 2013. All rights reserved. Processing
Sample Processing – Atellica® 1500 Analyzer
Reviewing Results
1. Select Database on the Atellica® UAS 800
software.
2. Select a sample from the Sample List.
3. Results are displayed in the Selected Sample
area.
4. Use the Filter to narrow results.

33

© Siemens
Page 33 AG 2013. All rights reserved.
Sample Processing – Atellica® 1500 Analyzer
Result Flags
Flag Description
Review is necessary

Invalid sample

Empty cuvette

! Low level sample

Skipped

To confirm. Sample requires manual review based on custom rule.

QC passed

QC failed

34

© Siemens
Page 34 AG 2013. All rights reserved.
Sample Processing – Atellica® 1500 Analyzer
Rerunning a sample
1. Select a sample on the Database screen.
2. Select Rerun.
3. If diluting the sample, choose dilution factor.
• As a shortcut, hold the left/right arrow on keyboard to move through the
dilution factor. For example, to choose a dilution factor of 5.0, you don't have to
click from 1.0 to 5.0. You can hold the arrow and it will quickly move forward.
4. Place the sample on the CLINITEK Novus® Analyzer sample rack handler.
Note: Diluted samples should be loaded on the Atellica® UAS 800 rack handler.
See more information on running diluted samples on the next slide.
5. Select Start on the CLINITEK Novus screen.
Note: if running a diluted sample on the Atellica® UAS 800 system, select Start
on the Atellica® 1500 Analyzer.

When sampling on the CLINITEK Novus system is complete, the rack moves along the
sample rack handler to the Atellica® UAS 800 Analyzer.
Note: The minimum volume required to run the sample on both systems is 2.6 mL.
35

© Siemens
Page 35 AG 2013. All rights reserved.
Sample Processing – Atellica® 1500 Analyzer
Diluting Samples in a Connected System
• Dilution factors are not entered on the CLINITEK Novus® Analyzer; therefore, diluted samples should not be run on the CLINITEK Novus® Analyzer.
• If the Atellica® UAS 800 Analyzer is not able to determine results due to an overcrowded sample, the Rerun option may be used to dilute and re-run the
sample to obtain a result. In this case, the diluted sample(s) should only be run on the Atellica® UAS 800 Analyzer. A dilution factor should be entered to
calculate the undiluted sample result. Caution: As is common on sediment analyzers, dilution may cause deterioration of sediment particles. Sediment
particles present in low number may be missed upon dilution. Each laboratory should establish its own protocols to verify results accuracy for diluted
samples.

36

© Siemens
Page 36 AG 2013. All rights reserved.
Sample Processing – Atellica® 1500 Analyzer
Printing sample and QC results
1. Select sample(s) on the Atellica® UAS 800 Database screen.
2. Select Outputs.
3. Select Print.
4. Select the check.

Note: Only validated results can be printed, or saved, or send to LIS.

37

© Siemens
Page 37 AG 2013. All rights reserved.
Hardware Overview
Sample Processing
Review Questions
Review Questions

1. After racks are loaded onto the sample rack handler, how do you start the run?

2. What is the minimum volume required to run a sample on both analyzers?

3. Where are sample results viewed?

4. How are QC results printed?

38

© Siemens
Page 38 AG 2013. All rights reserved.
Software Overview
Sample Processing
Review Questions
Review Questions Answer Key

1. Select Start on the CLINITEK Novus® analyzer software

2. 2.6 mL

3. Atellica® UAS 800 analyzer Database screen

4. Atellica® UAS 800 analyzer Database screen, select QC result(s), select Outputs, select Print

39

© Siemens
Page 39 AG 2013. All rights reserved.
Calibration – CLINITEK Novus® Analyzer
Preparing Calibrator Rack Performing Calibration
1. Select System.
Rack Position Calibrator
2. Select Calibration.
1 Bleach 3. To add a new lot select Change.
2 CAL #4 • Select Add.
• Enter a lot.
3 CAL #1 • Select an expiration date.
4 CAL #2 4. Select Next.
5. Select Start.
5 CAL #3
6. The calibration status of passed or
Note: Allow calibrators to equilibrate failed will display at the end of the run.
to room temperature before using.
Reviewing Calibration Results
1. Select Results.
2. Select Calibration.
3. Select All Results.
40

© Siemens
Calibration
Page 40 AG 2013. All rights reserved.
Hardware Overview
Calibration
Review Questions
Review Questions

1. The calibrators should reach which temperature before use?

2. What is the proper placement of bleach and calibrators in a rack?

41

© Siemens
Page 41 AG 2013. All rights reserved.
Software Overview
Calibration
Review Questions
Review Questions Answer Key

1. Room temperature

2. Position 1 – Bleach, Position 2 – CAL #4, Position 3 – CAL #1, Position 4 – CAL #2, Position 5 – CAL#3

42

© Siemens
Page 42 AG 2013. All rights reserved.
Quality Control – Atellica® UAS 800 Analyzer
Adding new QC lot information Running a QC test
1. Select Quality Control. 1. Follow QC vendor instruction to mix the QC material in its container.
2. Select Add in the Low or High Level Lots List pane. 2. Pour at least 2 mL of low and high level control solutions into
appropriately labeled test tubes.
3. Select the Liquid type.
3. Place the test tubes in a rack. Low level control solution in position 1
4. Enter the lot number.
and high level control solution in position 2.
5. Select the Expiration date.
4. Place the rack on the sample rack handler.
6. Enter the RBC and WBC limit ranges.
5. On the QC Settings screen, select Low Level Lot and High Level Lot
7. Select the check. checkboxes for the appropriate lots.
6. Select Start QC.
7. Select the check.
8. When testing is complete, a message appears indicating QC Passed
or QC Failed.

43

© Siemens
Quality Control
Page 43 AG 2013. All rights reserved.
Quality Control – Atellica® UAS 800 Analyzer
Reviewing QC results
1. Select Database.
2. Select Data view or Gallery on the lower-right for more details.

Reviewing QC graphs
1. Select Quality Control.
2. Select QC Graphs.
3. Select the date range from the drop-down calendar.
4. Select Update.

44

© Siemens
Page 44 AG 2013. All rights reserved.
Quality Control – CLINITEK Novus® Analyzer
Running a QC test Reviewing QC results at the end of a run
1. Pour at least 2 mL of each control into appropriately labeled test 1. Results automatically appear when the QC run is complete.
tubes.
2. Use the scroll buttons to review details at the top of the screen.
2. Place the test tubes in a rack. Control 1 in position 1, Control 2 in
3. Use the navigation bar to proceed to the next control.
position 2, Control 3 in Position 3 (if applicable).
3. Place the rack on the sample rack handler. Reviewing QC results for monthly review
4. Select System. 1. Select Results from the Home screen.

5. Select Control. 2. Select Control.

6. Verify the onscreen control lots are correct. 3. Enter search criteria.

7. To add a new lot, select Change. Reviewing QC Graphs for monthly review
• Select Add. 1. Select Results from the Home screen.
• Enter the control lot and select Enter. 2. Select Control.
• Enter the expiration date and select Enter. 3. To graph all results, select All Results and then Graph.
8. Select Next. 4. To graph specific analytes or controls, select the analyte/control
and select Enter.
9. Select Start.
45

© Siemens
Page 45 AG 2013. All rights reserved.
Hardware Overview
Quality Control
Review Questions
Review Questions

1. Which limit ranges need to be entered for quality control material on the Atellica® UAS 800 analyzer?

2. What screen do you have to be in to start QC on the Atellica® UAS 800 analyzer?

3. How do you start a QC run on the CLINITEK Novus® analyzer?

46

© Siemens
Page 46 AG 2013. All rights reserved.
Software Overview
Quality Control
Review Questions
Review Questions Answer Key

1. RBC and WBC

2. Quality Control from the Menu bar

3. Select System from the Home screen, select Control, make the necessary lot selections and press Start.

47

© Siemens
Page 47 AG 2013. All rights reserved.
Maintenance – Atellica® 1500 Analyzer

Interval Maintenance Task Instrument User Guide


Daily Empty and clean cuvette bin Atellica™ UAS 800 Analyzer Chapter 7
Clean the sample rack handler Both Chapter 7
Clean the front and rear cuvette guides Atellica™ UAS 800 Analyzer Chapter 7
Check the washing liquid bottle Atellica™ UAS 800 Analyzer Chapter 7
Empty and clean the waste water bottle Atellica™ UAS 800 Analyzer Chapter 7
Perform daily disinfecting rinse Atellica™ UAS 800 Analyzer Chapter 7
Clean the SG well CLINITEK Novus® Analyzer Chapter 4
Empty the liquid waste bottle CLINITEK Novus® Analyzer Chapter 4
Monthly Clean the microscope objective Atellica™ UAS 800 Analyzer Chapter 7
Clean the centrifuge door and centrifuge arm Atellica™ UAS 800 Analyzer Chapter 7

48

Maintenance
Maintenance
© Siemens
Page 48 AG 2013. All rights reserved.
Maintenance – Atellica® 1500 Analyzer

Interval Maintenance Task Instrument User Guide


Periodic Clean the analyzer exterior Atellica™ UAS 800 Analyzer Chapter 7
Clean the drip tray Atellica™ UAS 800 Analyzer Chapter 7
Rinse the washing liquid bottle Atellica™ UAS 800 Analyzer Chapter 7
Remove empty cuvette cartridges Atellica™ UAS 800 Analyzer Chapter 7
Clean the washing liquid bottle Atellica™ UAS 800 Analyzer Chapter 7
Prime the pump CLINITEK Novus® Analyzer Chapter 4
Clean the card platform CLINITEK Novus® Analyzer Chapter 4
Clean the card grippers CLINITEK Novus® Analyzer Chapter 4
Clean the racks CLINITEK Novus® Analyzer Chapter 4
Clean the rack sensors CLINITEK Novus® Analyzer Chapter 4
Clean the pad sensor CLINITEK Novus® Analyzer Chapter 4

49

Maintenance
© Siemens
Page 49 AG 2013. All rights reserved.
Monthly Maintenance – Atellica® UAS 800 Analyzer
Clean the microscope objective 2
3 & 4
1. Open the front cover.
2. Turn the microscope arm toward the
front of the analyzer. Do not remove
the securing screw.
3. Gently wipe the microscope objective
with a cloth dipped in 70% isopropyl
alcohol.
4. Dry the objective with a clean cloth.
5. Turn the microscope arm back to its
original location.
6. Close the front cover.

50
Monthly
© Siemens
Page 50 AG 2013. All rights reserved.
Maintenance
Monthly Maintenance – Atellica® UAS 800 Analyzer
Clean the centrifuge cover and centrifuge arm
1. Open the front cover.
2. Remove the front cuvette guide holding it at a slight angle to avoid bumping the
cuvette carousel. 3
3. Pull the black knob on the centrifuge cover to release the cover.
4. Remove the centrifuge cover.
5. Grasp the center of the centrifuge arm and carefully pull to remove it.
6. Wipe the centrifuge cover and arm with 70% isopropyl alcohol.
7. Rinse the centrifuge cover and arm with water and dry them.
8. Replace the centrifuge arm by aligning it with the magnet. The magnet will pull the
arm into place.
9. Replace the centrifuge cover by aligning the pin on the knob with the clot on the door.
10.Replace the front cuvette guide.
11.Close the front cover.
5

51

© Siemens
Page 51 AG 2013. All rights reserved.
Periodic Maintenance – Atellica® UAS 800 Analyzer
Performing periodic maintenance tasks
Refer to the Atellica® UAS 800 Analyzer User Guide for detailed
instructions for each task.
1. Clean the analyzer exterior.
2. Clean the drip tray (if necessary).
3. Rinse the washing liquid bottle.
4. Remove empty cuvette cartridges.
5. Clean the washing liquid bottle.

52
Periodic
© Siemens
Page 52 AG 2013. All rights reserved. Maintenance
Periodic Maintenance – CLINITEK Novus® Analyzer
Performing periodic maintenance tasks
Refer to the CLINITEK Novus® Analyzer Operator’s Guide for
detailed instructions for each task.
1. Prime the pump.
2. Clean the card platform.
3. Clean the card grippers.
4. Clean the racks.
5. Clean the rack sensors.
6. Clean the pad sensor.
7. Clean the barcode reader.

53

© Siemens
Page 53 AG 2013. All rights reserved.
Database Backup – Atellica® 1500 Analyzer
Perform database backup
1. Select Database.
2. Select Outputs.
3. Select Full or Anonymized.
4. Select the target location.
5. Select the check to confirm.
6. Select the check to save.
7. Select the x to close the window.

54

© Siemens
Page 54 AG 2013. All rights reserved.
Hardware Overview
Maintenance
Review Questions
Review Questions

1. Which component needs to be removed from the Atellica® UAS 800 analyzer before the centrifuge cover and arm can be
cleaned?

2. Which cleaning solution is used to clean the Atellica® UAS 800 analyzer microscope objective?

3. Which button on the Database screen provides access to the back up procedure?

55

© Siemens
Page 55 AG 2013. All rights reserved.
Software Overview
Maintenance
Review Questions
Review Questions Answer Key

1. Front cuvette guide

2. 70% isopropyl alcohol

3. Outputs

56

© Siemens
Page 56 AG 2013. All rights reserved.
Training Checklist – Atellica® 1500 Analyzer
To document that a facilitation event occurred, work with the learners to complete the following checklist for your records only. This does not serve as the final sign off for the
customer. It is up to the facility to determine competency for their employees.

Competency Objectives Complete Competency Objectives Complete


System Overview Identify major hardware components Maintenance Perform daily maintenance
Navigate the software Perform monthly maintenance
Routine Operations Log into the software Perform periodic maintenance

Determine the status of supplies Perform database backup


Calibration (CLINITEK Prepare calibrators
Load supplies and empty waste
Novus® Analyzer)
Process patient samples Process a calibration
View patient results Review calibration results
Print sample results
Quality Control Add new QC lot information
Process QC samples
View QC data
Observer: ______________________________________
Operator: ______________________________________
Date: _________________________________________

Training Checklist
Page 57
Please note that the learning material is for training purposes only!

For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers.
This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not
necessarily reflect the latest version of the software and hardware available at the time of the training.

The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions.

Note: Some functions shown in this material are optional and might not be part of your system.

Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the
future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information.

The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages.

All names and data of patients, parameters and configuration dependent designations are fictional and examples only.

All rights, including rights created by patent grant or registration of a utility model or design, are reserved.

Atellica, CLINITEK Novus, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective
owners.
Product availability may vary from country to country and is subject to varying regulatory requirements. Please contact your local representative for availability.

Copyright © Siemens Healthcare GmbH 2019

Global Siemens Healthineers Headquarters


Henkestr. 127
91052 Erlangen, Germany
Phone: +49 9131 84 0
siemens.com/healthineers
58
Effective Date: 2/2/2019 | HOOD05162002985708
Unrestricted © Siemens Healthcare GmbH, 2019

You might also like