6995.02.100.equipment List.r06.mr0

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Client Shell Location La Canonja Code 6995 Project New Boiler Plant New Steam Boilers Language English

FOR00216/03
AUDIT SCOPE DOCUMENT Nº Power, kW - S C P N F
LIST
Existent Existent Existent
Author Reviewed by Approved by Nº drawing Area Part Code Issue date Revision Review date EQUIPMENTS TOTAL Indeterminate Nou Futur
s/mod a/mod pendent
01 M.Rabbai M.Rabbai X.Curiel 6995.00.010/11/12/13 Boiler room 28 14
02 M.Rabbai M.Rabbai X.Curiel 6995.00.002 Boiler room 19 13 4
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
EQUIPMENTS LIST Author: M.Rabbai Document: 6695.02.001a
Client: Shell Reviewed by: M.Rabbai Issue date: 20/03/2020
Location: La Canonja Approved by: X.Curiel Revision: 6
Code: 6995 Nº drawing: 6995.00.010/11/12/13 Data revision: 02/10/2020
Logo client Project: New Boiler Area Nº Equipments 16
Plant: New Steam Boilers Part Boiler room FOR00216/03

New, Future
S/m,C/m,
Pending,
Design code and Delivery
Item Denomination Main characteristics Power, kW Material Reference Price, Euros Revision
certification time

TOTAL 27,83 0,00 €

Type: Fire tube


Flow: 1750 Kg/h
Thermal power: 1.327 kW
Work pressure: 8,5 barg Boiler: Carbon TRD-300:2001
Design pressure: 12,3 barg steel
F-1002 A Steam Boiler 7,50 N 2 months ATTSU 0
Total volum: 1.580 L Economizer: CE certification
Class II Duplex 2055 (2014/68/UE)
Dimentions (LxWxH): 4x1,95x2,3 m
With economizer
Natural Gas

Type: Fire tube


Flow: 1750 Kg/h
Thermal power: 1.327 kW
Work pressure: 8,5 barg Boiler: Carbon TRD-300:2001
Design pressure: 12,3 barg steel
F-1002 B Steam Boiler 7,50 N 2 months ATTSU 0
Total volum: 1.580 L Economizer: CE certification
Class II Duplex 2055 (2014/68/UE)
Dimentions (LxWxH): 4x1,95x2,3 m
With economizer
Natural Gas

Type: Vertical Cylinder Design TRD-300:2001 2 months,


Volume: 360 L supplied
V-1001 Blowdown tank Carbon steel N ATTSU - 0
Design pressure: atm. CE certification with
(2014/68/UE) boilers

Type: Horizontal Cylinder Design


Volume: 3000L TRD-300:2001 2 months,
Vessel: Carbon
Vessel dimentions (ØxH): 1,2 x 3 m supplied
V-1002 Deaerator tank 2,00 steel N ATTSU 5
Dome dimentions (ØxH): 0,35 x 1,05 m CE certification with
Dome: Duplex
Working temperature: 105ºC (2014/68/UE) boilers
Design pressure: 0,5 barg

Type: vertical centrifugal pump


2006/42/CE
Flow: 2,3 m3/h 2 months,
EN 809:1998 ATTSU
supplied
P-1003 A Feed boiler pump Discharge head: 10 barg 2,2 Titanium N Grundfos CR3- - 5
Working temperature: 105ºC with
2004/108/CE 21
boilers
2009/125/CE
Type: vertical centrifugal pump
2006/42/CE
Flow: 2,3 m3/h 2 months,
EN 809:1998 ATTSU
supplied
P-1003 B Feed boiler pump Discharge head: 10 barg 2,2 Titanium N Grundfos CR3- - 5
Working temperature: 105ºC with
2004/108/CE 21
boilers
2009/125/CE
Type: vertical centrifugal pump
2006/42/CE
Flow: 2,3 m3/h 2 months,
EN 809:1998 ATTSU
supplied
P-1003 C Feed boiler pump Discharge head: 10 barg 2,2 Titanium N Grundfos CR3- - 5
Working temperature: 105ºC with
2004/108/CE 21
boilers
2009/125/CE
Type: vertical centrifugal pump
2006/42/CE
Flow: 2,3 m3/h 2 months,
EN 809:1998 ATTSU
supplied
P-1003 D Feed boiler pump Discharge head: 10 barg 2,2 Titanium N Grundfos CR3- - 5
Working temperature: 105ºC with
2004/108/CE 21
boilers
2009/125/CE

---
Amine Injection
A-1004 Package Type: Dose pump 0,025 N 3 months BWT 5
CE
(Skid Water)
certification

--- 2 months,
Additives pump
supplied
A-1005 (Oxigen Type: Dose pump 1,0 N ATTSU - 0
CE with
scavenger)
certification boilers

--- 2 months,
Additives pump supplied
A-1006 Type: Dose pump 1,0 N ATTSU - 0
(phosphate) CE with
certification boilers

ASME Sec.VIII
Type: coil sample cooler Div.1
E-1002 Sample cooler Design temperature: 120ºC Alloy 625 N 2 months IBERFLUID 5
Design Pressure: -1/20 barg CE
certification
EQUIPMENTS LIST Author: M.Rabbai Document: 6695.02.001a
Client: Shell Reviewed by: M.Rabbai Issue date: 20/03/2020
Location: La Canonja Approved by: X.Curiel Revision: 6
Code: 6995 Nº drawing: 6995.00.010/11/12/13 Data revision: 02/10/2020
Logo client Project: New Boiler Area Nº Equipments 16
Plant: New Steam Boilers Part Boiler room FOR00216/03

New, Future
S/m,C/m,
Pending,
Design code and Delivery
Item Denomination Main characteristics Power, kW Material Reference Price, Euros Revision
certification time

--- 2 months,
supplied
E-1003 Sample cooler Type: coil sample cooler Duplex N ATTSU 3
CE with
certification boilers

--- 2 months,
supplied
E-1004 Sample cooler Type: coil sample cooler Duplex N ATTSU 3
CE with
certification boilers

In red: Pending information

(*) Delivery time have to be confirmed by the manufacturer.


EQUIPMENTS LIST Author: M.Rabbai Document: 6695.02.001a
Client: Shell Reviewed by: M.Rabbai Issue date: 20/03/2020
Location: La Canonja Approved by: X.Curiel Revision: 6
Code: 6995 Nº drawing: 6995.00.002 Data revision: 02/10/2020
Logo client Project: New Boiler Area Nº Equipments 19
Plant: New Steam Boilers Part Boiler room FOR00216/03

New, Future
S/m,C/m,
Pending,
Design code and Delivery
Item Denomination Main characteristics Power, kW Material Reference Price, Euros Revision
certification time

TOTAL 18,70 0,00 €

Type: Horizontal Cylinder Design


Volume: 1800 L ASME Sec VIII div
Condensate 1
T-1001 Vessel dimentions (ØxH): 1,2 x 1,5 m Carbon Steel N 1 months CALDITEC 5
Vessel
Dessign temperature: 150ºC CE certification
Design pressure: Atm.

Type: Vertical Cylinder Design, Lower


head: plane, upper head: Klopper.
UNE-EN 13121-3
Volume: 40.000 L
T-1003 Water Tank PRFV N 2 months AIQSA 5
Vessel dimentions (ØxH): 3 x 6 m CE certification
Dessign temperature: 60ºC
Design pressure: Atm.

2014/68/UE
MMF Filter (SKID Type: Multimedia filter
S-1001 A 0,10 Housing: PRFV F 3 months (*) Future 3
Condensate) Flow: 1,75 m3/h CE certification
2014/68/UE
MMF Filter (SKID Type: Multimedia filter
S-1001 B 0,10 Housing: PRFV F 3 months (*) Future 3
Condensate) Flow: 1,75 m3/h CE certification
Active Carbon 2014/68/UE
Type: Granular Actived Carbon
S-1002 Filter (SKID 0,10 Housing: PRFV F 3 months (*) Future 3
Flow: 1,75 m3/h CE certification
Condensate)
Active Carbon 2014/68/UE
Type: Granular Actived Carbon
S-1003 Filter (SKID 0,10 Housing: PRFV F 3 months (*) Future 3
Flow: 1,75 m3/h CE certification
Condensate)
Type: Sand Filter 2014/68/UE
Sand filter
S-1004 Flow: 4,6 m3/h 0,10 Housing: PRFV N 3 months BWT 5
(SKID Water) CE certification
Flow: 250 Nm3/h
Natural Gas Inlet pressure: 1,5 barg
A-1001 CE certificacion N - 2
Station Outlet pressure: 100 mbarg

Type: resin softing plant 2014/68/UE


Softneing Plant
A-1002A Flow: 4,6 m3/h 0,10 Housing: PRFV N 3 months BWT 6
(SKID water) CE certification
Type: resin softing plant 2014/68/UE
Softneing Plant
A-1002B Flow: 4,6 m3/h 0,10 Housing: PRFV N 3 months BWT 6
(SKID water) CE certification
Type: centrifugal pump
Flow: 1,75 m3/h EN 809:1998
P-1001 A Condensate pump Dif. Head: 50 mcl 4,00 Duplex N 3 months FLOWSERVE 5
Working Temperature: 100ºC CE certification

Type: centrifugal pump


Flow: 1,75 m3/h EN 809:1998
P-1001 B Condensate pump Dif. Head: 50 mcl 4,00 Duplex N 3 months FLOWSERVE 5
Working Temperature: 100ºC CE certification

Type: centrifugal pump


EN 809:1998
DA Feed Water Flow: 4,6 m3/h
P-1002 A 2,20 Carbon steel N 3 months FLOWSERVE 5
Pump Dif. Head: 40 mcl CE certification

Type: centrifugal pump


EN 809:1998
DA Feed Water Flow: 4,6 m3/h
P-1002 B 2,20 Carbon steel N 3 months FLOWSERVE 5
Pump Dif. Head: 40 mcl CE certification

Type: centrifugal pump


Flow: 8,7 m3/h EN 809:1998
P-1004 Backwater pump Dif. Head: 40 mcl 5,50 Carbon steel N 3 months FLOWSERVE - 5
CE certification

Softener
Type: Dosing pump ---
regeneration
P-1005 0,10 CE N 3 months BWT - 6
pump
certification
(SKID water)
Type: Plate heat exchanger
Design pressure: -1/+10 barg ASME Sec. VIII
Design Temperature: 150ºC Plates: Titanium
Div. 1
E-1001 Heat exchanger Dimentions: 340x340x890 mm (L x W x Gaskets: EPDM N 2 months ALFALAVAL - 5
Frame: C. Steel
H) CE certification

In red: Pending information

(*) Delivery time have to be confirmed by the manufacturer.

You might also like