Technical Information

Overview of WEC and control system designations

Scope of application
This document applies to: International
Mechanical Induction Installation Update Precast concrete tower assembly
Electrical Rotor blade Grid connection Concrete repair Precast concrete tower prestressing

E-10 E-30 E-40/6.44 E3 E-66/18.70 E-82 E4 E-126


E-12 E-30/3.30 E-44 E-66/20.70 E-92 E-126 EP4
E-15 E-32 E-48 E-70 E4 E-101 E-141 EP4

© Copyright ENERCON GmbH. All rights reserved


E-16 E-33 E-53 E-70 E4-2 E-101 E2
E-17 E-40 E-58/10.58 E-70 E4-3 E-103 EP2
E-18 E-40/6.44 E-58/12.58 E-82 E-112
E-20 E-40/6.44 E1 E-66 E-82 E2 E-115
E-26 E-40/6.44 E2 E-66/18.66 E-82 E3 E-115 E2

CS12 CS30 CS44a CS58b CS82a CS112a


CS16 CS31a CS44b CS66 CS82b CS126a
CS17 CS32 CS48a CS70a CS101a
CS20 CS40 CS58a CS70b CS101b
EP4-CS-01

Document details
Document ID TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations

Confidentiality INTERNAL

Date Language DCC Plant/Department


2016-09-20 en DD Service Deutschland GmbH / Electrical Engineering

---

---

TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations i of ii


Technical Information
Overview of WEC and control system designations
Revision details
Rev010 Changes to descriptions and product range

© Copyright ENERCON GmbH. All rights reserved


TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations ii of ii
Technical Information
Overview of WEC and control system designations

Designations of WECs and control systems


To help manage and classify the electrical components (assemblies and PCBs) and software of a wind energy converter, special designations
have been assigned to the various control system types of ENERCON WECs.
Each designation consists of a maximum of four parts:
CS Abbreviation for “Control System“
xxx Max. 3-digit number that identifies the main control system type

© Copyright ENERCON GmbH. All rights reserved


x 1 letter if there are different control system versions (does not apply to some older WEC types)
-xx 2-digit number for further hardware distinction with identical software

Starting with control system EP4-CS-01, the control system designations follow a somewhat different structure; systems that are completely new develop-
ments will use the same structure.

Why this designation system was introduced


Due to the multitude of WEC types and designs, it is no longer possible to match the electrical components and software programs to a particular WEC
type according to its official designation, which is primarily based on its mechanical design. For example, two WECs with different official designations may
use the same electrical control system type, or different control system versions may be needed for WECs with the same official designation (based on me-
chanical design).
In order to always ensure unambiguous classification, both the control system designation and the official WEC designation are indicated on the type plates
of assemblies etc. (provided there is enough space).

TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations 1 of 8


Technical Information
Overview of WEC and control system designations

Official Addi- Designation / Addi- Nominal pow- Current


WEC desig- tional type of control tional er of WEC in Rotor di- product
nation info system info kW ameter in m range Description / design / remark
E-10 CS20 -02 30 10 No 2008 prototype
E-12 CS12 30 12 No Small quantities (5)
E-15 CS16 55 15 No Thyristor inverter, 6-pulse, identical to E-16
E-16 55 16 No Thyristor inverter, 6-pulse

© Copyright ENERCON GmbH. All rights reserved


E-15 became E-16 due to rotor diameter
E-17 CS17 80 17 No Up to serial no.: 15: Thyristor inverter, 6-pulse
Starting at serial no. 15: Thyristor inverter, 12-pulse, identical to
E-18
E-18 80/100 18/19/20 No E-17 became E-18 due to rotor diameter
E-20 CS20 -01 100 20 No 2006 and 2008 prototypes
E-26 CS30 280 26 No E-30 with 26 m rotor diameter.
1 power cabinet 250 kW (280 kW due to modified Power Con-
trol PCB and modified generator)
E-30 200/230 30 No 1 power cabinet 250 kW
Control system similar to CS40 / CS66
E-30/3.30 CS31a -01 300 30/31 No 1 power cabinet 300 kW
Pitch control similar to CS30, remaining control system similar
to CS44b
E-33 -02 330 33.4 No 1 power cabinet, replaces E-30/3.30 with blade type 30-4 (new
gearless E-33!)
E-32 CS32 300 32 No Thyristor inverter, 12-pulse
300/340 33 No E-32 became E-33 due to rotor diameter (old E-33 with gear!)
E-33 J CS32 380 33 No 12 E-33 with gear and certain modifications in NL
E-40 CS40 -01 500 40 No Combined control and power cabinet, approx. 45 units, operat-
ing voltage 500 V

TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations 2 of 8


Technical Information
Overview of WEC and control system designations

Official Addi- Designation / Addi- Nominal pow- Current


WEC desig- tional type of control tional er of WEC in Rotor di- product
nation info system info kW ameter in m range Description / design / remark
-02 500/540 40/44 No 2 power cabinets 250 kW (same as CS30/CS66)
E-40/6.44 E1 CS44a -01 600 40/42/44 No 1 power cabinet 600 kW. Some WECs were installed on
500-kW towers  P-Max = 500 kW: Serial no. 43...
E1 = E-40 nacelle and generator casing

© Copyright ENERCON GmbH. All rights reserved


E2 -02 600 40/42/44 No 1 power cabinet 600 kW, egg-shaped casing, slewing ring bear-
ing, other equipment same as E1
E3 -03 600 40/42/44 No 1 power cabinet 600 kW, modified hub, rotor lock and brake on
outside of rotor disk, tall nacelle control cabinet
E2 CS44b -02 600 40/42/44 No 2 power cabinets 300 kW
E3 -03 600 40/42/44 No 2 power cabinets 300 kW
-04 600 40/42/44 No 2 power cabinets 300 kW; with yaw inverter
E-44 CS48a -02 500/900 44 Yes Export only
IEC wind class Ia
Version with 500 kW only available in GB and IE
-04 200/250 44 Yes E-44 with reduced power and equipment
250 KW: only GB and IE, 200 KW: only IT
E-48 -01 500/800 48 Yes Blade type 481, newly developed control system, replaces
E-40/6.44 with blade type 406
IEC wind class IIa
Version with 500 kW available in GB and IE

TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations 3 of 8


Technical Information
Overview of WEC and control system designations

Official Addi- Designation / Addi- Nominal pow- Current


WEC desig- tional type of control tional er of WEC in Rotor di- product
nation info system info kW ameter in m range Description / design / remark
E-53 -03 800 52.9 Yes IEC wind class III a
Also with 500 kW, available in GB and IE
E-58/10.58 CS58a -01 1000 58 No 2 power cabinets 600 kW (control system same as CS70a)
CS58b -01 1000 58 No 4 power cabinets 300 kW (control system same as CS70b)

© Copyright ENERCON GmbH. All rights reserved


E-58/12.58 1200 58 No 4 power cabinets 300 kW (control system same as CS70b)
E-66 CS66 1500 66/70 No 6 power cabinets 250 kW (control system similar to CS70a)
E-66/18.66 CS70a -01 1800 66 No E-66/18.70 (CS70a) with 66 m rotor diameter
E-66/18.70 -01 1800 70 No 3 power cabinets 600 kW (control system same as CS58a,
similar to CS66)
CS70b -01 1800 70 No 6 power cabinets 300 kW
(optional: 8 power cabinets, chopper and UPS)
E-66/20.70 -02 2000 70 No 8 power cabinets 300 kW
(optional: chopper and UPS, e.g. to comply with e-on regula-
tions)

TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations 4 of 8


Technical Information
Overview of WEC and control system designations

Official Addi- Designation / Addi- Nominal pow- Current


WEC desig- tional type of control tional er of WEC in Rotor di- product
nation info system info kW ameter in m range Description / design / remark
E-70 E4 -03 2000/2300 71 No E-66/20.70 with new rotor blade type (70-4) and new spinner
(only different blade type -> other characteristic curves, etc.),
replaces E-66/20.70 with blade type 70-3
8 - 9 power cabinets 300 kW, chopper and UPS as options
CS82a -01 2300 No New control system

© Copyright ENERCON GmbH. All rights reserved


E4 -2 Yes IEC wind class Ia
Revised mechanical design, with aluminium casing, 6 nacelle
fans, changed position of stator sub-distribution system, cable
lengths
2.3 MW: FT: 8 power cabinets 300 kW, FTQ: 9 power cabinets
300 kW
Also with 1500 kW, available in GB and IE
-3 Yes Same as E42 but with GRP casing
E-82 CS82a -02 2000 82 No Nacelle with new ventilation design,
FT: 7 power cabinets 300 kW, FTQ: 8 power cabinets 300 kW
-03 2000/3000 82 No 11, max. 14 power cabinets
E2 -04 2000/2300 82 Yes IEC wind class IIa
Separate rectifier, 6 nacelle fans, revised mechanical design,
stator shield
2 MW: FT: 7 power cabinets 300 kW, FTQ: 8 power cabinets
300 kW,
2.3 MW: FT: 8 power cabinets 300 kW, FTQ: 9 power cabinets
300 kW
E3 -06 3,000 82 No E2 with 3 MW, longer generator, water-cooled generator
FD/FT: 11 power cabinets 300 kW, FTQ: 12 power cabinets
300 kW
FT, FTS, FTQ, FTQS, FD

TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations 5 of 8


Technical Information
Overview of WEC and control system designations

Official Addi- Designation / Addi- Nominal pow- Current


WEC desig- tional type of control tional er of WEC in Rotor di- product
nation info system info kW ameter in m range Description / design / remark
E4 -07 2350/3000 82 Yes Wind class IA based on CS82a control system
Version with 3000 kW only for export
E5 -09 2350 82 No Development cancelled

© Copyright ENERCON GmbH. All rights reserved


TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations 6 of 8
Technical Information
Overview of WEC and control system designations

Official Addi- Designation / Addi- Nominal pow- Current


WEC desig- tional type of control tional er of WEC in Rotor di- product
nation info system info kW ameter in m range Description / design / remark
E-92 -08 2000/2350 92 Yes IEC wind class IIa
Based on CS82a control system
Version with 2000 kW only for export
E-103 EP2 CS82b -01 2350 102.8 In dev. IEC wind class IIIa, electronics and software same as CS82a;

© Copyright ENERCON GmbH. All rights reserved


Electrical equipment with Performance Level D (PLd)
E-101 CS101a -01 3050 101 Yes IEC wind class IIa
New control system
FT: 11 power cabinets 300 kW, FTQ: 12 power cabinets
300 kW
-04 Yes Version with asymmetrical generator
E2 -03 3500 101 Proto- IEC wind class Ia
type

CS101b - 02 In dev. IEC wind class Ia, PCBs and software same as CS101a; elec-
trical equipment with PLd, series E-101 E2
E-115 CS101a -02 3,000 115 Yes IEC wind class IIa
11 - 12 power cabinets
-05 Yes Version with asymmetrical generator
E2 CS101b -01 3200 115 In dev. IEC wind class IIIa, electronics and software same as CS101a;
Electrical equipment with PLd
E-112 CS112a -01 4500/6000 114 No 24 power cabinets 300 kW (Prototype: 20 power cabinets)
CS126a -02 E-112 upgraded to CS126a control system.
For control cabinets and pitch boxes also specify CS112a.
There are also special pitch control programs for CS112a.
E-126 -01 6000/7580 127 Yes 6 MW: FT: 28 power cabinets 300 kW

TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations 7 of 8


Technical Information
Overview of WEC and control system designations

Official Addi- Designation / Addi- Nominal pow- Current


WEC desig- tional type of control tional er of WEC in Rotor di- product
nation info system info kW ameter in m range Description / design / remark
7.5 MW: FT: 28 power cabinets 300 kW, FTQ: 32 power cabi-
nets 300 kW
-03 7580 127 Yes IEC IA, 16 yaw drives, only for export
E-126 EP4 EP4-CS-01 4200 127 Yes IEC wind class IIa
Prototype Q1/2016

© Copyright ENERCON GmbH. All rights reserved


E-141 EP4 4200 141 In dev. IEC wind class III a
Electronics, software, electrical equipment identical to E-126
EP4

1 Points of contact
Service technicians Technical Service Dispatch
Technical Service Dispatch ESC Electrical Engineering department

TD-esc-02-de-en-10-002 Rev010 Overview of WEC and control system designations 8 of 8