Standard Report

30KAV - 30KAV 0451


Date: 4/29/2022 1:56 PM Prepared By: Ekawit Tangtrakarn

30KAV0451A
Air Cooled Screw Chiller with Greenspeed Intelligence
Performance Information
Mode Cooling
Cooling Capacity tonR 123.2
Efficiency (EER) Btu/W·h 10.62
(IILFLHQF\ &23ߢ kW/kW 3.114
Efficiency (kW/tonR) kW/tonR 1.129
Unit Power Input kW 139.1
IPLV.IP kW/tonR 0.6176
Sound Power Level (LwA) dBA 103
Sound Pressure Level (LpA) dBA 83
Minimum Capacity % 30
Operating Weight lb 9403
Shipping Weight lb 9696
Unit Dimensions (LxWxH) in 170x89x94
Maximum Pressure Drop ft H2O 29.8
Minimum Pressure Drop ft H2O 0.964

Operating Conditions Unit Information


System element Evaporator Condenser Manufacturing Source Shanghai, China
Fluid Type FW - Refrigerant R-134a
Fluid Concentration % - - Refrigerant Weight lb 220
(Circuit 1)
Fouling Factor h·ft²·°F/Btu 0.000100 -
Fluid

Refrigerant Weight lb -
Leaving Temperature °F 45.00 -
(Circuit 2)
Entering Temperature °F 55.00 -
Number Of Passes 2
Fluid Flow gpm 294.6 - Number Of Compressors 1
Pressure Drop ft H2O 8.46 - Number Of Fans 6
Altitude ft - 0.000
Entering Air Temperature °F - 95.0 Electrical Information
Air

Minimum Outdoor Air Temperature °F - 32.0 Unit Voltage V-Ph-Hz 400-3-50


Entering Air Humidity % - 87.0 Standby Power kW 0.1500
Total Condenser Fan Air Flow At 70F CFM - 63700 Power Factor 0.92
Circuit 1 Circuit 2
Max Unit Current Draw A 286 -
(RLA)
Max Start Up Current A 286 -
(ICF)
Nominal Unit Current A 218 -
Draw (A)

Unit Configuration Documentation


Included Options Technical Drawing
Revit File

Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI
Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.
http://www.ahridirectory.org

NG Screw Chiller Builder Version 1.5.0.0 (Asia)


Performance Report
30KAV - 30KAV 0451
Date: 4/29/2022 1:56 PM Prepared By: Ekawit Tangtrakarn

30KAV0451A
Air Cooled Screw Chiller with Greenspeed Intelligence

Load Line
Unit Performance
Percent of Full Load Capacity % 100.00 90.00 80.00 70.00 60.00 50.00 40.00 30.00
Cooling Capacity tonR 123.2 110.8 98.53 86.21 73.90 61.58 49.27 36.95
Percent of Full Load Power % 100.0 86.78 75.73 62.78 51.70 41.69 33.13 24.26
Unit Power Input kW 139.1 120.7 105.4 87.33 71.93 57.99 46.09 33.75
Efficiency (kW/tonR) kW/tonR 1.129 1.089 1.069 1.013 0.9733 0.9417 0.9355 0.9134
Evaporator Data
Fluid Entering Temperature °F 55.00 53.99 52.99 51.99 50.99 49.99 48.99 48.31
Fluid Leaving Temperature °F 45.00 45.00 45.00 45.00 45.00 45.00 45.00 45.00
Constant Primary Flow Rate gpm 294.6 294.6 294.6 294.6 294.6 294.6 294.6 294.6
Fluid Pressure Drop ft H2O 8.46 8.47 8.49 8.50 8.52 8.53 8.55 8.56
Fouling Factor h·ft²·°F/Btu 0.000100 0.000100 0.000100 0.000100 0.000100 0.000100 0.000100 0.000100
Condenser Data
Entering Air Temperature °F 95.0 95.0 95.0 95.0 95.0 95.0 95.0 95.0

Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI
Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.
http://www.ahridirectory.org

NG Screw Chiller Builder Version 1.5.0.0 (Asia)


Performance Report
30KAV - 30KAV 0451
Date: 4/29/2022 1:56 PM Prepared By: Ekawit Tangtrakarn

Integrated Part Load Value


IPLV.IP kW/tonR 0.6176
Unit Performance
Percent of Full Load Capacity % 100.00 75.00 50.00 25.00
Cooling Capacity tonR 121.3 90.98 60.65 30.33
Unit Power Input kW 137.8 73.80 34.05 12.50
Efficiency (kW/tonR) kW/tonR 1.136 0.8112 0.5614 0.4121
Evaporator Data
Fluid Entering Temperature °F 54.00 51.49 48.99 46.50
Fluid Leaving Temperature °F 44.00 44.00 44.00 44.00
Fluid Flow Rate gpm 290.1 290.1 290.1 290.1
Fouling Factor h·ft²·°F/Btu 0.000100 0.000100 0.000100 0.000100
Condenser Data
Entering Air Temperature °F 95.0 80.0 65.0 55.0

Non-Integrated Part Load Value


NPLV.IP kW/tonR 0.6067
Unit Performance
Percent of Full Load Capacity % 100.00 75.00 50.00 25.00
Cooling Capacity tonR 123.2 92.37 61.58 30.79
Unit Power Input kW 139.1 74.07 34.09 12.21
Efficiency (kW/tonR) kW/tonR 1.129 0.8019 0.5536 0.3965
Evaporator Data
Fluid Entering Temperature °F 55.00 52.49 49.99 47.50
Fluid Leaving Temperature °F 45.00 45.00 45.00 45.00
Fluid Flow Rate gpm 294.6 294.6 294.6 294.6
Fouling Factor h·ft²·°F/Btu 0.000100 0.000100 0.000100 0.000100
Condenser Data
Entering Air Temperature °F 95.0 80.0 65.0 55.0

The NPLV is not an AHRI 550/590 or AHRI 551/591 metric and is not certified. It is based on ambient temperature varying linearly from the full load ambient to 55 °F at 25% load.

Certified in accordance with the AHRI Air-Cooled Water-Chilling Packages Certification Program, which is based on AHRI Standard 550/590 (I-P) and AHRI
Standard 551/591 (SI). Certified units may be found in the AHRI Directory at www.ahridirectory.org.
http://www.ahridirectory.org

NG Screw Chiller Builder Version 1.5.0.0 (Asia)

You might also like