SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALAI) SALIGRAMAM, CHENNAI. REFERENCE TITLE ESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES. DESIGN BASIS The pile has been designed in accordance with the provisions of IS 2911 (Part 1/ Sec 3) : 2010 400 mm and 350 mm square RCC Driven Precast Segmental Piles have been proposed Required axial compression capacity of the pile |) 400 mm Sq. = 152t ii) 350 mm Sq. = 87 t Check for axial capacity of pile is done as per IS 456 - 2000 (Reaffirmed 2011); Annexure B, Clause B - 3.1. The driving and handling stress of pile has been checked. Reinforcement steel shall be Fe 500. Concrete grade shall be M 40. SHEET 1 of 19 CONTRACT NO. DATE : 11.01.2018 CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI PREPARED BY: JCONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI J.Shamini FORM NO: Si/DD/DC/01/1, DATE 26.04.2006 -NIOR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI 'STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALA) SALIGRAMAM, CHENNAI. TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES REFERENCE 400mm SQ. RCC DRIVEN PRECAST SEGMENTAL PILES ) CHECK FOR AXIAL CAPACITY OF PILE The Axial Capacity of the Pile is checked as a short column as follows : P= Fee. Asc + Fet- Act Where P= Axial capacity of the pile in kg Foe = Permissible stress in concrete in direct compression in kg / cm? = 100 kg/cm? ‘Age = CIS. area of concrete excluding any finishing material and reinforcing steel in cm? Permissible compressive stress for column bars in kg / cm? 1900 kglom? Cross sectional area of the longitudinal stee! in cm? Grade of concrete = M40 ; Steel Reinforcement = Fe 500 ‘The minimum area of steel required as per Cl.6.12.1 of IS 2914 (Part 1 / Sec 3) : 2010 is 1.5% = 45x40x40 _ 5, 2 Astrequired = oo = 24 em Reinforcement Details Provide 8 nos of 20mm ¢ bars as main longitudinal reinforcement ( 25.12 cm’). Provide mm ¢ links @ 75 mm o/c in both the ends within 1200mm of the segment. Provide 8mm ¢ links @ 22 mm o/c in the middle portion of the segment. Therefore the axial capacity of pile, P; P = 100 x (40 x 40 - 25.12) + 1900 x 25.12 = 205216 kg = 205.22t P = 205.22t > 152t required axial capaci 1S 456 : 2000 (Reaffirmed 2011) (From Table21) (From Table22) ICONTRACT NO.: - ICUSTOMER : Mis APPASWAMY REAL ESTATES LIMITED, CHENNAI CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI SHEET 2 of 19 DATE : 11.01.2018 Prepared by J.SHAMINI ‘CHECKED BY fom no:sxooyocu/s WV-BAURRUMAR bre :26042008 OR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO. 10) ARCOT ROAD (NSK SALAI) SALIGRAMAM, CHENNAI REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES ii) REINFORCEMENT DETAILS. Reinforcement requirement for the segment length considered for the design is 13 m; as per C1.6.12.1 of IS 2911 (Part1/Sec3) : 2010 as a guide line. Size of the pile = 400 mm Sq. Capacity of pile req.= 152 t Steel reinforcement = Fe 500 Grade of concrete = M 40 Length of the segment upto= 13m Cover to main Reinforcement = 40 mm As per IS 2911 (Partt/ Sec 3):2010; C16.12.1 = 325 (30 to 40) The minimum area of stee! requiredas per CI.6.12.1 of IS 2911 (Part 1/Sec 3): 2010 is 1.5% Therefore minimum area of longitudinal oT 4.50% of cross sectional area ofthe pile reinforcement required 150 x 40 x 100 24.00 cm? Ast required = Reinforcement details for 400mm Sq. RCC driven precast pile: Provide 8 nos of 20mm 6 bars as main longitudinal reinforcement ( 25.12 cm’). Provide Y 8 @75mm c/c in both the ends within 1200mm of the segment. Provide Y 8 @ 225 mm cic in the middle portion of the segment. ISHEET 3 of 19 feel scach Il ci DATE : 11.01.2018 ICUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI. Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI. J.SHAMINI CHECKED BY fom no:siyo0/eC/M/, ATE: 042008, si SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALAl) SALIGRAMAM, CHENNAI. REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES LINKS FOR 400mm SQUARE RCC DRIVEN PRECAST SEGMENTAL PILES Links at ends Volume of links at ends 0 0.6% of the gross volume of piles Links at ends have to be provided for a et pee tee ero = 1200 mm. Volume of inks at ends = 2S _* 40 x __40__x_ 120) 100 = 1182 cm? Length ofthelink = 1440 = omm == 144 cm Considering 8 mmdia,, links and spacing (d) required, 3d distance at ends length oflinks = x = 0.5 x = _ Volume of links at ends spacing (4) 120 1440x058 x = 1152 cm’ spacing (d) d= 7.536cm = 75 mm Provide Y 8 @ 75 mm clc in both the ends within 1200 mm of the segment. Links at middle Volume of links at ends = 0.2 %of the gross volume of piles Links at middle have to be provided = 1000 mm 02 x 40 x 40 x 100 ~ 100 = 320 cm* . SHEET 4 of 19 oneal DATE : 11.01.2018 CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNA| Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI \J.SHAMINI : SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALA) SALIGRAMAM, CHENNAI, REFERENCE [TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES Length of the link = 1440 mm = 144 om Considering 8 — mmdia., links and spacing (4) required, 100 length oflinks = x = 5X) = _Volume of links at middle ‘spacing (d) 144 05 = 320 ° x x — = spacing (d) om d= 2261cm = 225 mm Provide Y 8 @ 225 mm clcin the middle portion of the segment. ISHEET 5 of 19 beens esrdllaciia DATE : 11.01.2018 CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNA JJ.SHAMINI Fomano:siyo0/oc/u/t SIMPLEX INFRASTRUCTURES LIMITED DESIGN CAI CULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI ISTOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT During hoisting, the pile will be suspended at one point near the head and the bending moment will be the least when it is pulled at a distance of 0.293L and the value of bending moment will be W 1/23.3 Bending moment during hoisting = = 2901 tm 29.01 kNm ROAD (NSK SALAl) SALIGRAMAM, CHENNAI. REFERENCE ITITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES CHECK FOR HANDLING STRESS Length of segment, = 13.00 m Reinforcement provided = of 1.50% of cls area of pile 13.0 | 0.40 = 326 Weight of pilesegment = 04 x 04 x 1300 x 26 w= 52 t During handling the bending moment to be allowed for design ; wl Bending moment during handling ee (2 point pick up) 466 _ 52 x 130 46.6 = 1.451. tm = 1451. kNm ICONTRACT NO.: - CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI ISHEET 6 of 19 DATE : 11.01.2018 Prepared by J.SHAMINI om no: styoo/econ OR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALA!) SALIGRAMAM, CHENNAI, REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES For M40 grade of concrete oeae = 13 Nimm? ‘(28 Pet lable 21 of IS 456 2000) 280 Modular ratio (m) 7 3X Soe 7 280 3 x 18 m = 7.179 Determination of Neutral Axis 2 ao +(1.5m-1) x Ag x (n= de) = mx x(d-n) 400 x nt ee (15x TAT9 1) 2 x 942 x [nn - 50 )= 7179 x 942 x (3500 - oj 200 n? + 15965.69 on - 2827207.7 =0 n= 8550 mm Depth of Critical Neutral Axis 1 Te xd An Su From IS 456 - 2000 for MX ate Fe 500 1 on = 0.55, le = ————————_ «x_ 3500 a 275 oO, == 275 Nimm® TAS x13 ne = 887 mm TM > on = SHEET 7 of 19 ee DATE : 11.01.2018 CUSTOMER : Mis APPASWAMY REAL ESTATES LIMITED, CHENNA|. Prepared by [CONSULTANT, IF ANY : Mis JAYAM CONSULTANTS PRIVATE LTD, CHENNA\ \J.SHAMINI SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALAI) SALIGRAMAM, CHENNAI. REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES As the actual neutral axis is less than the critical neutral axis, stress in tensile steel will reach its permissible value first. Compressive stress in concrete eee et eee m d-n 275 85.50 a 7.179 350.( 85.5 12.38 Nim? < 13. Nimm? ° " 4 n= de e = xe 7 85.5 50.0 => x 1238 855 c= 6.14 N/mm? Moment of Resistance 5 —tye (<- a + (1.8m - 1)XAwex cx (d= d) 400 85.50 12.38 85. 2 [880 +[15 x TATQ - 1) x 92 x 514 x ( 350 - 500) = 8226317259 Nmm = 82 kNm >> 29.01 kNm bending moment during hoisting. ISHEET 8 of 19 CONTRACT NO.: DATE : 11.01.2018 CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI. Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI. \J.SHAMINI * For no: s1yoo/ocoxrt 1.V.BATAKUMAR, bare :26042008 ENIOR CONSULTANT. SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI ISTOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALAl) SALIGRAMAM, CHENNAI. TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES REFERENCE iv) CHECK FOR DRIVING STRESS Driving resistance The driving stress on pile. = CIS area of pile As per Cl 6.11.6 of IS 2911 (Part 1 / Sec 3) - 2010 where n= efficiency of blow = 0.8 (max) Cross sectional area of the pile shall be calculated as the overall sectional area of the pile including the ‘equivalent area of reinforcement. Provided reinforcement = 8 -Y 20 Aq provided = 2512 mm? A; equivalent concrete area. = mx Ag. = 7.479 x 2512 Ay = 18034.87 mm? A; I of te luding steel 1 cross sectional area of concrete exclu re ca = 400 x 400 area A, = 157488 mm? =A + = 1803487 + Total area = 1755229 mm? Driving Resistance Driving Resistance 2512 157488 Axial capacity x Factor of safety (Assuming factor of safety as 2) = 152 x 2 304 t CONTRACT NO.: - CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI ISHEET 9 of 19 DATE : 11.01.2018 Prepared by J.SHAMINI Fomuno:siyoorocreyt SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET ROAD (NSK SALAI) SALIGRAMAM, CHENNAI. ‘TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT REFERENCE The driving stress on pile Driving resistance CIS area of pile 304 x 10° x _ 9.807 ( 175522.9 Driving stress 2 - 4 A a 21.0 N/mm? is < 40 Nimm* (28 days compressive strength of concrete) 5 SHEET 10 of 19 eae DATE : 11.01.2018, CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI Prepared by CONSULTANT, IF ANY : Mis JAYAM CONSULTANTS PRIVATE LTD, CHENNAI. J.SHAMINI Foantno:styooyocx/s bate 2e08 3008 OR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI ISTOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALAl) SALIGRAMAM, CHENNAI. TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES REFERENCE 350mm SQ. RCC DRIVEN PRECAST SEGMENTAL PILES i) CHECK FOR AXIAL CAPACITY OF PILE ‘The Axial Capacity of the Pile is checked as a short column as follows : P= Feo. Asc t Fat: Ast Where capacity of the pile in kg Permissible stress in concrete in direct compression in kg / cm? = 100 kg/cm? CIS. area of concrete excluding any finishing material and reinforcing steel in cm? F., = Permissible compressive stress for column bars in kg / cm? = 1900 kg/cm? = Cross sectional area of the longitudinal steel in cm? 2 Grade of concrete =M 40 ; Steel Reinforcement = Fe 500 The minimum area of steel required as per Cl.6.12.1 of IS 2011 (Part 4 / Sec 3) : 2010 is 1.6% 7 4.5%35x35 0 _ 2 Ast required == a = 18.38 om’ Reinforcement Details Provide 4 nos of 25 mm $ bars as main longitudinal reinforcement ( 19.64 om’). Provide 8mm ¢ links @ 75 mm c/c in both the ends within 1125mm of the segment. Provide 8mm $ links @ 225 mm c/c in the middle portion of the segment. Therefore the axial capacity of pile, P; P = 100 x (35 x 35 - 18.38) + 1900 x 18.38 = 155584 kg = 155.584 P = 155.581 > 871 requi d axial capacity. IS 456 : 2000 (Reaffirmed 2011) (From Table21) (From Table22) CONTRACT NO.: - CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI. SHEET 11 of 19 DATE : 11.01.2018 Prepared by |J.SHAMINI |ECKED BY FORM No: st/oD/ocyou/t bn) V.BALAKUMAR owTE 26.08.2006 SENIOR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI — |STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALA\) SALIGRAMAM, CHENNAI. REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES. ii) REINFORCEMENT DETAILS Minimum reinforcement requirement for the segment length considered for the design is 13 m; as per Cl.6.12.1 of IS 2911 (Part1/Sec3) : 2010 as a guide line, Size of the pile = 350 mm Sq. Capacity of pile= 87 t Steel reinforcement = Fe 500 Grade of concrete = M40 Length of the segment upto = 13.00. m Cover for Reinforcement= 40 mm As per IS 2911 (Partt/ Sec 3): 2010; C16.12.1 I 13.0 — = —— = 3714 (30 to 40) b 0.35 The minimum area of steel required as per C1.6.12.1 of IS 2911 (Part 1/Sec 3):2010 is 1.6% ‘Therefore minimum area of longitudinal main 4.50% of cross sectional area ofthe ple reinforcement required 1.50 35 Ast required = . 100 = 18.38 cm? Reinforcement details 350mm Sq. RCC driven precast pile: Provide 4 nos of 25mm ¢ bars as main longitudinal reinforcement ( 19.64 cm’). Provide Y 8 @ 75mm cic in both the ends within 1125mm of the segment. Provide Y 8 @ 225 mm cic in the middle portion of the segment. SHEET 12 of 19 eaececela DATE : 11.01.2018, CUSTOMER : Mis APPASWAMY REAL ESTATES LIMITED, CHENNAI Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNA JSHAMINE ECKED BY FORM No: S/oD/0cj03/1 V.BALAKUMAR onTe 26.08.2006, SENIOR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALA) SALIGRAMAM, CHENNAI. REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES LINKS FOR 350mm SQUARE RCC DRIVEN PRECAST SEGMENTAL PILES Links at ends Volume of inks at ends = 0.6 % of the gross volume of piles Links at ends have to be provided for a distance Sit SA on oy = 1050 mm say 1125 mm Volume of inks at ends = CS __* _88_x_98 an 700 = 826.9 cm? Length ofthelink = 1240 mm = = 124. cm Considering 8 _~—smmdia,, links and spacing (d) required, 3d distance at ends length oflinks x = 0.5 = X= _ Volume of links at ends spacing (d) 113 1240 x 05) x ————___ = 826.88 cm’ spacing (d) d= 848 cm = 75 mm Provide Y 8 @ 75 mm cle in both the ends within 1125. mm of the segment. Links at middle Volume of links at ends 0.2% of the gross volume of piles Links at middle have to be provided 1000 = mm 02 x 35 x 35 x 100 Volume of links at ends | 700 = 245 cm® SHEET 13 of 19 anneal DATE : 11.01.2018 CUSTOMER : Mis APPASWAMY REAL ESTATES LIMITED, CHENNAI Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNA. J.SHAMINI TECKED BY V.BALAKUMAR NIOR CONSULTANT Fon wo: st/oo/ncyou/t onre :26.08.2006 SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI ISTOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALAl) SALIGRAMAM, CHENNAI. REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES Length of the link = 1240 mm = 124 cm Considering 8 — mmdia., links and spacing (d) required, 100 length of links = x = 0.5) X= _ Volume of links at middle spacing (4) 100 124 Xeon OO areex ee = 245 om? spacing (d) d= 2543cm = 225 mm Provide Y 8 @ 225 mm clcinthe middle portion of the segment. SHEET 14 of 19 aeeieeas DATE : 11.01.2018 CUSTOMER : Mis APPASWAMY REAL ESTATES LIMITED, CHENNA Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI J.SHAMINI FoRMNo: styooyoc/oa/t DATE: 26082006 SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALA) SALIGRAMAM, CHENNAI. [TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES REFERENCE. CHECK FOR HANDLING STRESS Length of segment,L = 13.00 m Reinforcement provided 13.0 _ O3g 7 37-14 Blo Weight of pile segment = 0.35 x 0.35 x w= 40 ¢ During handling the bending moment to be allowed for design ; wi 46.6 40 x 130 46.6 1111 tm 14.11 kNm During hoisting, the pile will be suspended at one point near the head and the bending moment will be the least when it is pulled at a distance of 0.293L and the value of bending moment will be W1/ 23.3 Bending moment during hoisting = 40 x 130 23.3, 2221 tm 22.21. kNm of 1.50 %of c/s area of pile 130 x 25 Bending moment during handling =——— (2 point pick up) ICONTRACT NO.: = CUSTOMER : Mis APPASWAMY REAL ESTATES LIMITED, CHENNAI CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI ISHEET 15 of 19 DATE : 11.01.2018 Prepared by J.SHAMINI IECKED BY FORM NO: sI/OO/DCIONA 'V.BALAKUMAR DATE: 26.08.2006 SENIOR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALA) SALIGRAMAM, CHENNAI. REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES For M40 grade of concrete Gey. = 13 Nimm? (as per table 21 of IS 456 - 2000) 280 Modular ratio (m) = 3X ae - 280 3 x 13 m = 7.179 Determination of Neutral Axis bn? = i + (1.5 m-1) x Ae x (n= do) = mx Ay x(d-n) 360 + [15x 77 1) x 981.3 x [nn - 525) = 7179 x 9813 x [2o75 - “) 175 2 + ~~ 1630.93 «n - © 2599117.39 = 0 n= 8329 mm Depth of Critical Neutral Axis 1 n= xd te Ot From IS 456 - 2000 for MX Ge Fe 500 fi 0 = 0.55, ne = —————————_ x__2075 Pe 275 C5 2 275 Nimm? 7178 x18, ne = 75.4 mm te << on ISHEET 16 of 19 CONTRACT NO.: - DATE : 11.01.2018 CUSTOMER : Mls APPASWAMY REAL ESTATES LIMITED, CHENNAI Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI \J.SHAMINI CHECKED m orn no: st/oo/acyox/t \f V.BALAKUMAR are: 26.2008 SENIOR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALAI) SALIGRAMAM, CHENNAI. REFERENCE ITITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES As the actual neutral axis is more than the critical neutral axis, the extreme compressive stress in concrete reaches its permissible value first. Substitutingcas 13 Nimm® = 13.00 cos Stress in tensile steel Stress in tensile steel = amd fess tex ael7.18)x fel (207-50) ees. 20) 83.29 Stress in tensile steel = 240.04 Nimm? < 275 Nimm* Moment of Resistance a fe png («- 4 + (1.5m = 1)xAgx cx (d= dy) 2 3 350 x 83.29 x 13, 83.29 = 298 - +[(15 x 7.179 - 4 J 2 3 x 9813 x 461 x { 298 - 525) = 62397667.18 Nmm = 62 kNm >> 22.21 kNm bending moment during hoisting ISHEET 17 of 19 erase DATE : 11.01.2018 CUSTOMER : Mis APPASWAMY REAL ESTATES LIMITED, CHENNAI. Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNA\. J.SHAMINI [ECRED BY FALAKUMAR, FORM No siyDo/0C/04/1, DxTE: 26042006 ‘SENIOR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI |STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALA) SALIGRAMAM, CHENNAI. TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES REFERENCE iv) CHECK FOR DRIVING STRESS Te Driving resistance 2 The driving stress on pile CIS area of pile As per Cl 6.11.6 of IS 2911 (Part 1 / Sec 3) - 2010 where n= efficiency of blow = 0.8 (max) Cross sectional area of the pile shall be calculated as the overall sectional area of th equivalent area of reinforcement. Provided reinforcement 4. -Y 25 Ag provided = 1963 mm? ‘A; equivalent concrete area = mx Ax " 7479 x 1963 A 1408974 mm? ee ee aoe area A, = 1205375 mm? = A + & Totalarea = 1346272 mm? Driving Resistance Driving Resistance = 87 x 2 = pile including the 1962.5 = 1408974 + © 120537.5 Axial capacity x Factor of safety (Assuming factor of safety as 2) 174 ¢ ICONTRACT NO.: - CUSTOMER : Mis APPASWAMY REAL ESTATES LIMITED, CHENNAI CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNAI SHEET 18 of 19 DATE : 11.01.2018 Prepared by \J-SHAMINI KED BY FoRM No: si/on/0c/04/1, F, MBALAKUMAR, DATE: 26.08.2006 SENIOR CONSULTANT SIMPLEX INFRASTRUCTURES LIMITED DESIGN CALCULATION SHEET PROJECT : PILING WORKS FOR THE PROPOSED CONSTRUCTION OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 (OLD NO.10) ARCOT ROAD (NSK SALAI) SALIGRAMAM, CHENNAI. REFERENCE TITLE : DESIGN OF RCC DRIVEN PRECAST SEGMENTAL PILES Driving resistance 2 The driving stress on pile - CIS area of pile n 174 x10° x_ 9.807 : } - 4 134627.2 ( {08 15.7 Nimm? is < 40 Nimm? (28 days compressive " Driving stress strength of concrete) SHEET 19 of 19 een DATE : 11.01.2018 CUSTOMER : M/s APPASWAMY REAL ESTATES LIMITED, CHENNAI Prepared by CONSULTANT, IF ANY : M/s JAYAM CONSULTANTS PRIVATE LTD, CHENNA. J.SHAMINI DATE: 26042006 SENIOR CONSULTANT ‘This drawing is the property of Simplex Infrastructures Limited and is merely lent for limited uve subject STANDARD DRAWING SHEET FORM NO, SIL/DD/DRG/00/1 DATE 26.04.2008, to the condition that it shall not be reproduced, lent or used in any way detrimental to our i FEMALE JOINT “INKS Y0 © 7 o/c At Bort as ss Ze % Soot ¥20 — LIPTING HOOK (TYP.) B —j]—rue weap Provecrion RING oe c/o At ENDS y20 - LIFTING HOOK (TYP.) 60 {oto unas v8 © 75 (o/c aT BOTH ENDs (izsme)a 225.676 INT Mabou [ ap 350 C/S OF PILE —- BB (BOTTOM & TOP SEGMENTS) ww mene z| ay T (aon sex, DETAILS OF LIFTING HOOK PILE DETAILS: PILE | CONCRETE PE REINFORCEMENT AXIAL we SIZE | GRADE | SEGMENT caPACTTY 7 o/c ar (mm) MAIN’ STEEL cos wo 08 ‘AT ENDS IN THE MIDDLE 950 s@.| M40 BorToM 4- yes | ye @ 75 c/c | Ye @ 225 c/o er ANCHOR RODS (¥12) & TOP AT BOTH ENDS | IN THE MIDDLE . ‘SEGMENTS (1125 mm) anor PILE SHOR BOTTOM (0mm TH. Plate) TOP SEGMENT SEGMENT TYPICAL LONGITUDINAL SECTION OF PILE TRANSMITTAL STATUS: ‘REVISION NUMBER 0 B w a remem c/s, APPASWAMY REAL ESTATES LIMITED + SUBMITTED TO CUSTOMER/coNSULTANT ON | 11.01.2018) saan * COMMENTS/APFROVAL RECEIVED ON cals: NTS. M/s. JAYAM CONSULTANTS PRIVATE LID. liob Naw: PILING WORKS FOR THE PROPOSED CONSTRUCTION — [908 No: NOTES _& SPECIFICATIONS: oF MULT" STONEYED RESIDENTIAL APARTMENT AT DOOR. NO.20 4. ALL PILES ARE STANDARD DRIVEN PRECAST RCC SEGMENTAL PILES WITH FLAT HOTTOMED MILD STHEL SHOE AS PER SIMPLEX STANDARD PRACTICE. 2 COVER TO MAIN REINFORCEMENT SHALL BE 40m, 3. Y DENOTES HYSD DARS CONFORMING TO Fe S00 AS PER IS 1786 ; 2008, 4, ALL DIMENSIONS ARE IN mm, UNLESS OTHERWISE SPECIFIED, 6. AS PER SOIL CONDITION LENGTH OF PILE SEGMENT SHALL BE MODIFIED SUITABLY IP REQUIRED AFTER INSTALLING FEW PILES AT SITE, 66 WHEREVER NECESSARY PROVISIONS OF 1S 2011 (PART 1/SEC 9}2010 HAS BEEN FOLLOWED. RewNo.| Date (OLD NO.10) ARCOT ROAD, (NSK SALAT) SALIGRAMAM, CHENNAI SI [PRING CONTRACTOR: IMPLEX INFRASTRUCTURES LIMITED © |store] FoR arpmova, a yr ‘TYPICAL REINFORCEMENT DETAILS OF 350mm SQ. PILE lneamxc xo. REVISIONS pax, | pesiex | cm. | arrRo, fier. [bute (011/DD/ARELPPNSK/RA/P/001 0 {11.01.18 smET 1 oF @ PRINT DR. 11.01.2018 This drawing Je the property of Simplex Infrastructures Limited and is merely lent for limited use subject i 5 : i ? : i 3 5 i 3 £ i 4 i 5 3 5 FEMALE J01NT woe 75 o/c at Bord ms ss ce 3 Ta 3000 y20 ~ LIFTING HOOK (TYP.) [STANDARD DRAWING SHEET FORM NO. SIL/DD/DRG/00/1 DATE 28.04.2006, |-—Pu HEAD PROTECTION RING vee 75 o/c at Bort ENDS ans ye @ aes cere a oon 13000 y20 ~ LIFTING HOOK (TYP.) PILE DETAILS: 400 ea uns ¥8 © 75 C/e ar BoTH ENDS (200mm) 225 0/c {4 | oyna uapoue (2/ser) 400 Cpucowan, ui C/S OF PILE - BB (BOTTOM & TOP SEGMENTS) ‘veo - UPTING HOOK 78 [CLEAR] t q ial DETAILS OF LIFTING HOOK Pus concrerz| PME TRENTORORENT a Ye @ ye @ SIZE ‘GRADE ‘SEGMENT ‘CAPACITY 75 C/c aT 15 C/C aT (mm) ‘MAIN STEEL — (t) a ‘BOTH ENDS AT ENDS IN THE MIDDLE 400 sq.) uao | norm | 8-va0 | vee scyc | ve@ 225 c/c| 152 aCmOR ROBE (YA) & TOP AT BOTH ENDS | IN THE MIDDLE SEGMENTS oH, prorseon (1200 mm) sass sont | son BOTTOM (10mm TH. plate) TOP SEGMENT SEGMENT TYPICAL LONGITUDINAL SECTION OF PILE TRANSMITTAL STATUS: REVISION NUMBE ‘RO RL Re RS in M/s. APPASWAMY REAL ESTATES LIMITED + sumarrep 10 cusrows/consuima ox | i0i0i8 Soa 7 commns/ArPROVAL RECETED oN eum ne TW/s. JAYAM CONSULTANTS PRIVATE UID, los wa PILNG WORKS FoR THE PROPOSED CONSTRUCTION — [OW N= NOTES & SPECIFICA’ 4 [OF MULTI STOREYED RESIDENTIAL APARTMENT AT DOOR NO.29 1, ALL PILBS ARE STANDARD DRIVEN PRECAST RCC SEGMENTAL, PILES WITH FIAT BOTTOMED MILD STEEL (OLD NO.10) ARCOT ROAD, (NSK SALA!) SALIGRAMAM, CHENNAI SHOE AS PER SIMPLEX STANDARD PRACTICE. CONTRACTOR: 2. COVER TO MAIN REINFORCEMENT SHALL BE 40mm. SIMPLEX INFRASTRUCTURES LIMITED 8. Y DENOTES HYSD BARS CONFORMING TO Fe 00 AS PER 18 1786 : 2008, 4 ALL DIMENSIONS ARE IN om, UNLESS OTHKEVISE SPECIFIED. Ss] b ‘TYPICAL REINFORCEMENT DETAILS OF 400mm SQ. PILE 5. AS PER SOM CONDITION LENGTH OF PILE SEOMENT SHALL BE MODIFIED SUTARLY IF REQUIRED APRER >To INSTALLING FEN PULES At SITE. an BLS | |S fonamvc xo. [01s /o0/aneiernsk/ea/r/oo1 fo [rno1so (6 WHEREVER NECESSARY PROVISIONS OF IS 2011 (PART 1/SEC 3):2010 HAS BEEN FOLLOWED. ‘evo. | Date oman ‘pax. | pests | cam. | sppnn. to. PRINT Dr. 14.01.2018

You might also like