AEGIS one manual 5/7/99 8:57 am Page 1

Owner’s manual
AEGIS one manual 5/7/99 8:57 am Page 2

Introduction Positioning
Congratulations on choosing the Acoustic The AEGIS ONEs are best heard with the tweeters
Energy AEGIS ONE — a powerful compact two- at, or just below, ear height when the listener is
way loudspeaker which features metal seated. For serious listening the grilles are best
diaphragm technology and is capable of out- removed.
standing performance. Please take a few
moments to read this manual. The advice it Rigid support is essential for the speaker to develop its
contains will enable you to get the very best full detail and dynamic performance. Rigid stands
performance out of your Acoustic Energy loud- with spikes, cones or other methods of secure
speakers. mounting are recommended. ‘Free-field’ stand
mounting gives improved stereo separation and
The AEGIS ONE utilises metal cone mid-bass drive unit depth. If AEGIS ONEs are shelf mounted the support
technology, proven in the AE Reference series. The rigid must be firm; cones are still recommended beneath
anodised alloy cone ensures pure piston action and the cabinets.
also acts as a heat sink for the bonded voice coil. These
features provide exceptional clarity, transparency Closeness to room boundaries has a major impact
dynamics and power handling. on the low frequency performance. The speakers
should be kept away from corners (which will
The tweeter — or treble driver — is a high-quality silk produce booming). The speakers can be positioned
fabric dome unit integrating smoothly with the rest of fairly close to a back or side wall but should not be
the system. Both drive units are fully magnetically the same distance off the ground as from the rear or
shielded so that the speakers can be used in close prox- side wall.
imity to a TV screen or monitor for AV applications.
Experiment with the best position to achieve a full, yet
AEGIS ONE loudspeaker uses quality OFC internal clean bass response. Trust your judgement and ears.
wiring which enhances detail and transparency. For
exceptional results use AE UPOCC speaker cable which For best stereo imaging the speakers should be as far
is available from AE dealers and distributors. apart as they are from the listening position.
AEGIS one manual 5/7/99 8:57 am Page 3

Connection
Check that your amplifier is switched off before
installing your loudspeakers. Failure to do so may
result in speaker or amplifier damage.
Power Handling 20 – 120 watt

The diagram illustrates one loudspeaker only. The Impedance 8 ohm

Serial Number
positive (ribbed) cable from the amplifier positive (or
red) terminal should connect with the positive (red)
terminal on the loudspeaker. Similarly the negative
(smooth) cable should connect the amplifier negative DESIGNED AND ENGINEERED BY
ACOUSTIC ENERGY LIMITED, ENGLAND
MADE IN MALAYSIA

terminal (black) to the negative terminal (black) on the


loudspeaker.

After wiring up: Lower the volume to minimum,


switch on the amplifier, select the signal source and
then raise the volume to the listening level required.
LEFT SPEAKER

MAIN

R L

AMPLIFIER
AEGIS one manual 5/7/99 8:57 am Page 4

Specifications Warranty
HF unit 25 mm silk fabric dome, anti- Your Acoustic Energy loudspeakers are guaranteed against original
reflection pole. Ferrofluid cooled defects in materials, manufacture and workmanship for 3 years from
and damped. Magnetically the date of purchase. Please retain all original packaging materials for
shielded possible future use. We suggest that you complete details of purchase
now and keep this information in a safe place for future reference.
MF/LF unit Pure piston 130 mm AE driver
with 32 mm coil, high-power, Under this warranty Acoustic Energy agrees to repair any defect or,
long-throw magnet system and at the company’s discretion, replace the faulty component(s) without
lightweight alloy cone. charge for parts and labour. This warranty does not imply any
Magnetically shielded acceptance by Acoustic Energy or its agents for consequential loss or
damage and specifically excludes fair wear and tear, accident,
Crossover 2nd/3rd order at 2.8 kHz. High- misuse or unauthorised modification.
power inductors and polyester
capacitors. OFC wire to drive units This warranty is applicable in the United Kingdom only and does not
Power handling 20 – 120 watt max in any way limit the customer’s legal rights. Claims and enquiries
under the warranty for AE products purchased outside the UK should
Overall frequency response 38 Hz – 22 kHz be addressed to the local importers or distributors.

Frequency response ±3 dB 50 Hz – 20 kHz If you have reason to claim under the warranty please contact your
dealer in the first instance.
Sensitivity 90 dB/1 w/1 m
Impedance 8 ohm Dealer’s name:........................................................................................
Address: ..................................................................................................
Cabinet 25 mm MDF low diffraction front ................................................................................................................
baffle. 15mm MDF enclosure. Full ................................................................................................................
internal bracing. High-power, Date of purchase: ...................................................................................
gas-flowed, low-turbulence bass
Serial numbers: ......................................................................................
reflex port.
Terminals Gold-plated 2-way binding posts Acoustic Energy Limited
16 Bridge Road, Cirencester
Weight (excl. packaging) 7 kg each Gloucestershire GL7 1NJ
Tel +44 (0)1285 654432
Dimensions (WxHxD) 192 x 362 x 235 mm Fax +44 (0)1285 654430