STRUCTURAL ANALYSIS

& DESIGN REPORT

STRUCTURAL ANALYSIS
AND DESIGN REPORT
PROPOSED OFFICE
WAREHOUSE WITH
MEZZANINE

Location: 358 F. ORTIGAS, NEW ZANIGA, MANDALUYONG CITY, PHILIPPINES


Owner: MR. JOEL FERNANDO
STRUCTURAL ANALYSIS
& DESIGN REPORT

I. PROJECT DETAILS

Project Name : PROPOSED OFFICE WAREHOUSE WITH MEZZANINE


Location : 358 F. ORTIGAS, NEW ZANIGA, MANDALUYONG CITY, PHILIPPINES

Occupancy Category : STANDARD OCCUPANCY STRUCTURE


Building Structural System : Moment Resisting Frame Systems – Special Steel MF’s

II. REFERENCE CODE AND STANDARDS


- National Structural Code of the Philippines 2015

III. MATERIAL SPECIFICATIONS

Concrete – reinforced concrete design shall be in accordance with NSCP 2015. The specified minimum
compressive strength of the concrete by cylinder test at 28days age shall be as follows:
Foundation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20.7MPa (3000PSI)
Beams - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20.7MPa (3000PSI)
Columns - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20.7MPa (3000PSI)
Suspended Slab - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20.7MPa (3000PSI)
Slab on Grade - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 20.7MPa (3000PSI)
Lean Concrete - - - - - - - - - - - - - - - - - - - - - - - - - - - - -10.0MPa (1450PSI)

Reinforcing Steel – minimum yield strength of reinforcing bar shall be as follows:

16mmØ and smaller reinforcing bar - - - - - - - - - - - - - - 276MPa (Grade 40)


20mmØ and bigger reinforcing bar - - - - - - - - - - - - - - - 414MPa (Grade 60)

Structural Steel – All structural steel such as wide flange, angles, channels, pipes and plates shall conform to
ASTM A36 or equivalent with minimum yield strength of 248MPa.

Weld – Welding electrode shall be E70XX, minimum welding 6mm. Fu = 480MPa

Anchor Bolt – Anchor Bolt shall conform to ASTM 325 or equivalent. Anchor bolt shall be designed for maximum
tensile stress of 140MPa on the tensile stress area of the bolt.
STRUCTURAL ANALYSIS
& DESIGN REPORT

IV. DESIGN LOAD CRITERIA

Dead Loads (DL) – consist of the weight of all materials of construction incorporated into the building or other
structure, including but not limited to walls, floors, roofs, ceilings, stairways, finishes, cladding and other similarly
incorporated architectural and structural items, and fixed service equipment, including the weight of cranes.
STRUCTURAL ANALYSIS
& DESIGN REPORT

Live Loads (LL) – shall be the maximum loads expected by the intended use or occupancy but in no case shall
be less than the loads required by this section.

Z
STRUCTURAL ANALYSIS
& DESIGN REPORT
STRUCTURAL ANALYSIS
& DESIGN REPORT

Earthquake Loads (EQX & EQZ), section 208


STRUCTURAL ANALYSIS
& DESIGN REPORT
STRUCTURAL ANALYSIS
& DESIGN REPORT
STRUCTURAL ANALYSIS
& DESIGN REPORT
STRUCTURAL ANALYSIS
& DESIGN REPORT
STRUCTURAL ANALYSIS
& DESIGN REPORT
STRUCTURAL ANALYSIS
& DESIGN REPORT
STRUCTURAL ANALYSIS
& DESIGN REPORT

V. LOAD COMBINATIONS
STRUCTURAL ANALYSIS
& DESIGN REPORT

LOAD COMBINATION FOR DESIGN


LOAD COMB 6 1.4DL
LOAD COMB 7 1.2DL + 1.6LL
LOAD COMB 8 1.2DL + 0.5LL + 1.0EQX
LOAD COMB 9 1.2DL + 0.5LL - 1.0EQX
LOAD COMB 10 1.2DL + 0.5LL + 1.0EQZ
LOAD COMB 11 1.2DL + 0.5LL - 1.0EQZ
LOAD COMB 12 0.9DL + 1.0EQX
LOAD COMB 13 0.9DL - 1.0EQX
LOAD COMB 14 0.9DL + 1.0EQZ
LOAD COMB 15 0.9DL - 1.0EQZ

LOAD COMBINATION FOR DRIFT CHECK


LOAD COMB 6 1.4DL
LOAD COMB 7 1.2DL + 1.6LL
LOAD COMB 8 1.2DL + 0.5LL + 1.0EQX
LOAD COMB 9 1.2DL + 0.5LL - 1.0EQX
LOAD COMB 10 1.2DL + 0.5LL + 1.0EQZ
LOAD COMB 11 1.2DL + 0.5LL - 1.0EQZ
LOAD COMB 12 0.9DL + 1.0EQX
LOAD COMB 13 0.9DL - 1.0EQX
LOAD COMB 14 0.9DL + 1.0EQZ
LOAD COMB 15 0.9DL - 1.0EQZ

LOAD COMBINATION FOR DEFLECTION CHECK


LOAD COMB 6 1.4DL
LOAD COMB 7 1.2DL + 1.6LL
STRUCTURAL ANALYSIS
& DESIGN REPORT

VI. GEOMETRY

3D STRUCTURAL RENDERED VIEW


STRUCTURAL ANALYSIS
& DESIGN REPORT

VII. LOAD CALCULATION

Dead Load
1) Selfweight
Steel unit weight = 76.82 kN/m3
Concrete unit weight = 23.60 kN/m3

Tie
Floor Load Units MEZZANINE Roof Bea
ms
100mm thk Slab kN/m2 2.40 -
Floor finish kN/m2 0.77 -
Toppings kN/m2 0.60 -
Ceiling kN/m2 0.20 0.10
Ducting/MEPF kN/m2 0.10 0.20
Interior Partition kN/m2 0.50 -
Roof framing kN/m2 - 0.41
Roofing Sheet kN/m2 - 0.10 0
4.57 0.81

ROOF DEAD LOAD:


ROOFING SHEET = 0.10KPA X 2.5M = 0.25 KN/M
PURLINS = 0.10KPA x 2.5 = 0.25 KN/M
CEILING = 0.10KPA x 2.5 = 0.25 KN/M
DUCTING = 0.20 x 2.5 = 0.5 KN/M

ROOF LIVE LOAD:


RL= 0.60KPA X 2.5M = 1.5 KN/M