LED IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE WARNING RISK OF ELECTRIC SHOCK
INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
• Disconnect or turn off power before installation or servicing.
• To reduce the risk of death, personal injury or property damage from fire, • Verify that supply voltage is correct by comparing it with the luminaire label
electric shock, falling parts, cuts/abrasions, and other hazards please read all information.
warnings and instructions included with and on the fixture box and all fixture • Make all electrical and grounded connections in accordance with the
labels. National Electrical Code (NEC) and any applicable local code requirements.
• Before installing, servicing, or performing routine maintenance upon this • All wiring connections should be capped with UL approved recognized wire
equipment, follow these general precautions. connectors.
• Installation and service of luminaires should be performed by a qualified
licensed electrician.
• Maintenance of the luminaires should be performed by person(s) familiar with WARNING RISK OF BURN
the luminaires’ construction and operation and any hazards involved. Regular • Allow lamp/fixture to cool before handling. Do not touch hot lens, lamp,
fixture maintenance programs are recommended. guard, or enclosure.
• It will occasionally be necessary to clean the outside of the refractor/lens. • Do not exceed maximum wattage marked on luminaire label.
Frequency of cleaning will depend on ambient dirt level and minimum light • Follow all lamp manufacturer’s warnings, recommendations and restrictions
output which is acceptable to user. Refractor/lens should be washed in a on lamp operation including but not limited to: ballast type, burning position,
solution of warm water and any mild, non-abrasive household detergent, rinsed replacement, and recycling.
with clean water and wiped dry. Should optical assembly become dirty on the
inside, wipe refractor/lens and clean in above manner, replacing damaged
gaskets as necessary. WARNING RISK OF INJURY
• DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly
• Wear gloves and safety glasses at all times when removing luminaire from
packed so that no parts should have been damaged during transit. Inspect
carton, installing, servicing or performing maintenance.
to confirm. Any part damaged or broken during or after assembly should be
• Avoid direct eye exposure to the light source while it is on.
replaced.
• If the lamp is marked (Hg) it contains Mercury. Follow all disposal laws. For
more information on how to recycle LED electronic product please visit www. WARNING RISK OF INJURY
epa.gov.
• These instructions do not purport to cover all details or variations in equipment • Keep combustible and other materials that can burn away from lamp/lens.
nor to provide every possible contingency to meet in connection with • Do not operate in close proximity to persons, combustible materials or
installation, operation, or maintenance. Should further information be desired substances affected by heat or drying.
or should particular problems arise which are not covered sufficiently for the
purchaser’s or owner’s purposes, this matter should be referred to Acuity
Brands Lighting, Inc.
LED IMPORTANT SAFETY INSTRUCTIONS

WARNING RISK OF PRODUCT DAMAGE (1) This device may not cause harmful interference
(2) This device must accept any interference received, including
• Never connect components under load. interference that may cause undesired operation.
• Do not mount or support these fixtures in a manner that can cut the outer
jacket or damaged wire insulation. This device complies with Part 18 of the FCC Rules but may cause interference
• Never connect an LED product to an unapproved dimmer pack. Contact with cordless and cell phones, radios, televisions, and other electronic devices.
ABL directly for any dimmers not specifically recommended for the product. To correct the problem move the device away from the luminaire or plug into
• Unless individual product specifications deem otherwise: Allow for some a different outlet. This product may cause interference to radio equipment and
volume of airspace around fixture. Avoid covering LED fixtures with should not be installed near maritime safety communications equipment or
insulation, foam, or other material that will prevent convection or conduction other critical navigation or communications equipment operating between 0.45-
cooling. 30MHz.
• Unless individual product specifications deem otherwise: Maximum ambient
temperature is 90°C. Do not operate fixture at temperatures higher than Failure to follow any of these instructions could void product warranties.
this. For a complete listing of product Terms and Conditions, please visit www.
• Unless individual product specifications deem otherwise: Never mount acuitybrands.com.
in places where fixture will be exposed to rain, high humidity, extreme
temperature changes, or restricted ventilation. OUR BRANDS
• LED products are Polarity Sensitive. Ensure proper Polarity before
INDOOR/OUTDOOR: Lithonia Lighting, Carandini, Holophane, RELOC, Luimnis,
installation. • Electrostatic Discharge (ESD): ESD can damage LED fixtures.
Luminaire Led, Alight.
Personal ground-ing equipment must be worn during all installation or
INDOOR LIGHTING: Gotham, Mark Architectural Lighting, Peerless,
servicing of the unit.
Renaissance Lighting, Winona Lighting, Eureka, Indy, Healthcare Lighting,
• Do not touch individual electrical components as this can cause ESD,
Aculux.
shorten lamp life, or alter performance.
OUTDOOR LIGHTING: American Electric Lighting, Antique Street Lamps, Hydrel,
• There are no user-serviceable parts inside the unit. Do not rewire,
Tersen, Cyclone.
reconfigure, or modify the unit or attempt any repairs yourself. Additionally,
CONTROLS: DARK TO LIGHT, Lighting Control & Design, ROAM, Sensor
field replacement of the LED assembly or lamps is not allowed by UL
Switch, Synergy, Fresco, Blue Box, nLight, Pathway, Xpoint Wireless.
standards at this time. In the unlikely event, your unit may require service,
stop using the unit immediately and contact an ABL representative.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising
out of improper or careless installation or handling of its products.
All luminaires that contain electronic devices that generate frequencies above
ABL LED General Warnings, Form No. 503.203 © 2010 Acuity Brands Lighting,
9kHz from any component within the luminaire comply with one of the following
Inc. All rights reserved. 12/01/10
Part 15 of the FCC Rules. Operation is subject to the following two conditions:
SURFACE WALL| INSTALLATION

CAN ICES-005 (A) / NMB-005 (A)

FCC Compliance Statement ISED Canada Statement


This device complies with part 15 of the FCC Rules. Operation is This class A lighting equipment complies with innovation, Science
subject to the following two conditions: (1) This device may not and Economic Development (ISED) Canada Standard for radio
cause harmful interference, and (2) this device must accept interference-causing equipment ICES-005, 5th edition.
any interference received, including interference that may
cause undesired operation. This equipment has been tested Déclaration pour ISDE Canada
and found to comply wit the limits for a Class A digital device, Ce matériel d’éclairage de classe A est conforme avec la norme
pursuant to part 15 of the FCC Rules. These limits are designed sur le matériel brouilleur radio NMB-005, 5ième édition, publié
to provide reasonable protection against harmful interference par innovation, science et développement économique (ISDE)
when the equipment is operated in a commercial environment. Canada.
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference, to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user
will be required to correct their interference at their own expense.

20210302
APX5 | INSTALLATION GUIDE GYPSUM (G/RG)

1 2 A 3 B C
BLOCKING

GYPSUM

A
B

C
B
4 5 SERVICE
A

C B

C
MUD D

INSTALLATION STEPS
WARNING: Risk of fire and electrical shock - Fixture to be installed by qualified electrician according to local codes and ordinances.
WARNING: Ensure propoer handling of LEDs to limit common problems including: broken connection, loose wiring and damage from electrostatic discharge.
[A] - Wood or steel studs can be used for blocking, install gyp board then cut opening. For nominal lengths [A] - Housing connections: White+, Black-, Green, (if dimming is required): Purple Dim+, Pink Dim-
1 reference dimensions in chart, or consult submittal drawings for special lengths cut-outs.
[B] - Power feed connections through KO hole: White+, Black-, Green, (if dimming is required): Purple Dim+,
2 [B] - Align corner pins and connect fixture housings with rubber mallet until no gap remains.
[C] - Secure sections with joiner screws.
Pink Dim-
[C] - Attach fixture to blocking through gyp with #8 drywall scews in the pre-drilled holes in the side flanges. [A] - Align light engine section ends with appropriate lettering.
Fixture must be fastened to blocking at a miniumum of every 8” or less.
[D] - Mud over side and end flanges to edge of fixture. Finish should just cover bottom extrusion edge. 3 [B] - Attach safety tether on each light engine with provided flange nut.
[C] - Light engine connections: White+, Black-, Green, (if dimming is required): Purple Dim+, Pink Dim-
For rows proceed to step 2, for single light engine units proceed to step 4 [D] - Raise light engine sections into housing until spring brackets secure on inside of housing.
NOMINAL ROUGH OPENING DIMENSIONS Repeat steps for all light engines

NOMINAL [A] - Attach safety tether on each light engine with provided flange nut.
4
12FT 10FT 8FT 6FT 4FT 2FT 1FT
FIXTURE LENGTH [B] - Light engine connections: White+, Black-, Green, (if dimming is required): Purple Dim+, Pink Dim-
[C] - Raise light engine into housing until spring brackets secure on inside of housing.
ROUGH OPENING
LENGTH 139.13” 116.25” 93.35” 70.45” 47.55” 24.65” 13.20”
Service and Maintenence
ROUGH OPENING 2.50” - 2.63”
5 [A] - Insert screw driver into end baffle hole and slide downwards
[B] - Remove light engine for service.
WIDTH