PV Sys
PVsyst TRIAL
PVsyst TRIAL
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 18:56
with v7.2.0
Project summary
Geographical Site Situation Project settings
Rạch Giá Latitude 10.00 °N Albedo 0.20
Vietnam Longitude 105.08 °E
Altitude 8m
PVsyst TRIAL
Time zone UTC+7
Meteo data
Rạch Giá
Meteonorm 8.0 (1991-2009), Sat=100% - Synthetic
System summary
Stand alone system Stand alone system with batteries
PVsyst TRIAL
System information
PV Array Battery pack
Nb. of modules 18 units Technology Lithium-ion, NMC
Pnom total 5.40 kWp Nb. of units 7 units
Voltage 48 V
Capacity 840 Ah
Results summary
Available Energy 7186 kWh/year Specific production 1331 kWh/kWp/year Perf. Ratio PR 63.33 %
Used Energy 5806 kWh/year Solar Fraction SF 97.27 %
Table of contents
Project and results summary 2
PVsyst TRIAL
General parameters, PV Array Characteristics, System losses 3
Detailed User's needs 4
Main results 5
Loss diagram 6
Special graphs 7
PVsyst TRIAL
12/09/23 PVsyst Evaluation mode Page 2/7
Project: Rạch Giá
Variant: New simulation variant
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 18:56
with v7.2.0
General parameters
Stand alone system Stand alone system with batteries
PV Field Orientation
Orientation Sheds configuration Models used
PVsyst TRIAL
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 20 / 0 ° Diffuse Perez, Meteonorm
Circumsolar separate
User's needs
Daily household consumers
Constant over the year
Average 16.4 kWh/Day
PV Array Characteristics
PV module Battery
Manufacturer Generic Manufacturer Generic
Model JS300P 72 cells Model KBM216_2P13S 120Ah
(Original PVsyst database) Technology Lithium-ion, NMC
PVsyst TRIAL
Unit Nom. Power 300 Wp Nb. of units 7 in parallel
Number of PV modules 18 units Discharging min. SOC 10.0 %
Nominal (STC) 5.40 kWp Stored energy 36.0 kWh
Modules 9 Strings x 2 In series Battery Pack Characteristics
At operating cond. (50°C) Voltage 48 V
Pmpp 4792 Wp Nominal Capacity 840 Ah (C10)
U mpp 64 V Temperature Fixed 20 °C
I mpp 75 A
PVsyst TRIAL
Total PV power
Nominal (STC)
Total
Module area
Cell area
5
18
34.9
31.5
kWp
modules
m²
m²
Array losses
Thermal Loss factor DC wiring losses Serie Diode Loss
Module temperature according to irradiance Global array res. 15 mΩ Voltage drop 0.7 V
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC Loss Fraction 1.0 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst TRIAL
Loss Fraction -0.8 % Loss Fraction 2.0 % at MPP Loss Fraction 0.1 %
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 18:56
with v7.2.0
PVsyst TRIAL
W Hour/day Wh/day
Lamps (LED or fluo) 1 1546W/lamp 1.0 1546
TV / PC / Mobile 1 50W/app 3.0 150
Domestic appliances 2 750W/app 8.0 12000
Fridge / Deep-freeze 1 24 950
Dish- and Cloth-washer 1 2 1454
Other uses 1 230W tot 1.0 230
Stand-by consumers 24.0 24
Total daily energy 16354Wh/day
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
12/09/23 PVsyst Evaluation mode Page 4/7
Project: Rạch Giá
Variant: New simulation variant
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 18:56
with v7.2.0
Main results
System Production
Available Energy 7186 kWh/year Specific production 1331 kWh/kWp/year
Used Energy 5806 kWh/year Performance Ratio PR 63.33 %
Excess (unused) 1086 kWh/year Solar Fraction SF 97.27 %
PVsyst TRIAL
Loss of Load Battery aging (State of Wear)
Time Fraction 4.9 % Cycles SOW 86.6 %
Missing Energy 163 kWh/year Static SOW 80.0 %
PVsyst TRIAL
May 162.9 140.9 614.1 96.0 2.94 504.0 507.0 0.994
June 142.2 119.0 524.9 55.7 30.08 460.5 490.6 0.939
July 145.6 124.1 545.7 22.4 27.63 479.3 507.0 0.946
August 142.7 127.5 560.4 63.8 15.74 491.2 507.0 0.969
September 133.2 127.0 555.9 31.4 6.06 484.6 490.6 0.988
October 158.3 163.2 707.5 164.1 0.00 507.0 507.0 1.000
November 118.8 127.8 554.0 93.4 52.79 437.8 490.6 0.892
December 113.1 121.4 537.5 43.8 27.71 479.3 507.0 0.945
Year 1710.4 1648.0 7185.7 1085.6 162.95 5806.3 5969.2 0.973
Legends
GlobHor Global horizontal irradiation E_User Energy supplied to the user
GlobEff Effective Global, corr. for IAM and shadings E_Load Energy need of the user (Load)
PVsyst TRIAL
E_Avail Available Solar Energy SolFrac Solar fraction (EUsed / ELoad)
EUnused Unused energy (battery full)
E_Miss Missing energy
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 18:56
with v7.2.0
Loss diagram
1710 kWh/m² Global horizontal irradiation
PVsyst TRIAL
-2.93% IAM factor on global
-4.48%
-14.52% Unused energy (battery full)
PVsyst TRIAL
162.9 kWh
-3.78% Battery efficiency loss
PVsyst TRIAL
12/09/23 PVsyst Evaluation mode Page 6/7
Project: Rạch Giá
Variant: New simulation variant
PVsyst V7.2.0
VC0, Simulation date:
12/09/23 18:56
with v7.2.0
Special graphs
Daily Input/Output diagram
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL
PVsyst TRIAL