Professional Documents
Culture Documents
Influence of Current Ripple On Battery Degradation: Yuliya Preger, Jacob Mueller
Influence of Current Ripple On Battery Degradation: Yuliya Preger, Jacob Mueller
SAND2020-12931C
PRESENTED BY
Yu l i y a P re g e r, J a c o b M u e l l e r
versus
Dual-active bridge converter for grid Single phase AC-DC converter: 120 Hz
connection: 5-500 kHz
Uno et al. IEEE Trans. Veh. Technol., 2011, 60, 1505. Uddin et al. Appl. Energy, 2016, 178, 142.
3) What is the tradeoff between cost of suppression and accepting some extra degradation?
7 Current ripple can be studied in a lab setting
Uddin et al. Appl. Energy, 2016, 178, 142. Breucker et al. EVS27, 2013.
DC + AC conditions:
(1) Float at 3.8V or 4.2V
(2) Float at 3.8V or 4.2V + 1Hz; 2A (peak to peak)
(3) Float at 3.8V or 4.2V + 10Hz; 2A (peak to peak)
(4) Float at 3.8V or 4.2V + 1kHz; 2A (peak to peak)
(5) Float at 3.8V or 4.2V + 10kHz; 2A (peak to peak)
(6) Float at 3.8V or 4.2V + 100kHz; 2A (peak to peak)
AC generation: converter
DC + AC conditions:
(1) 30A/30A; 10-90% SOC + 120Hz; 10% DC (peak to peak)
(2) 30A/30A; 10-90% SOC + 120Hz; 200% DC (peak to peak) Bala et al. ECCE, 2012.
Assessing previous studies of current ripple
10
3) What is the tradeoff between cost of suppression and accepting some extra degradation?
14 Conclusions
3) What is the tradeoff between cost of suppression and accepting some extra degradation?
3a) Is suppression even needed for the conditions you’re interested in?
• Important question for grid energy storage
• New converters/materials with higher switching frequencies & amplitudes on the horizon
15 Acknowledgments
•Funded by the U.S. Department of Energy, Office of Electricity, Energy Storage program. Dr. Imre Gyuk,
Program Director.
•Sandia National Laboratories is a multi-mission laboratory managed and operated by National Technology
and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for
the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA-0003525.