ISO-14001

ISO-9001 SPECIFICATION SHEET

2-WIRE TYPE pH ANALYZER/TRANSMITTER Model: HDM-135A

FEATURES

• 2-wire pH transmitter with built-in microcomputer:


Field installation type pH analyzer / transmitter featuring isolated
output, digital indication and rainproof construction.
• Simplified calibration with standard solution:
Data of five different pH standard solutions can be stored in the
internal memory for single-action calibration. Stability judgement
function provides accurate calibration with standard solution, free
from operator error.
• Automatic determination of electrode quality:
The transmitter judges the electrode quality from it’s characteristics
during calibration with standard solutions. Degradation of
electromotive force at pH7, degradation of electromotive force per
pH and other information is displayed in the form of error
messages.
Characteristic data of each electrode can be called out to
determine the extent of degradation as required.
• Output range alteration:
The pH range of the output signal can be easily adjusted. STANDARD SPECIFICATION
• Output holding during maintenance work:
By switching the mode to ST-BY (standby) the output is kept at the Product Name : pH analyzer/transmitter
value just before the mode was switched therefore preventing Model : HDM-135A
disruption to the control system. Measurement Ranges
• External input for “hold” feature (Terminals 9-11 as option): pH : -1.00~14.00pH
The transmitter can receive a “hold” command signal from the mV : -600.0~+600.0mV
water jet cleaner and chemical cleaner to hold the output (4~20mA Temperature : 0.0~100.0°C (Indication only, no
DC) during cleaning. output-signal)
• Measured value shift: Indication System : Digital indication (LCD)
The measured value can be shifted by a pH value demanded for Resolution : pH; 0.01, mV; 0.1,
o
the convenience of process operation. (Shift width: ±1.0pH). temperature; 0.1 C
• Manual temperature compensation: Linearity : Within ±0.03pH (at equivalent input)
Manual temperature compensation function (0~100°C) can be Output Signal : 4~20mA DC isolated from input,
provided for use with electrodes which do not have temperature load resistance; max 650Ω
compensation functions. Output Range : Adjustable in 0.1pH steps, with
• Compliant with 1kΩ. temperature compensation resistance: minimum width of 2pH
Compliant with temperature compensation resistance of 10kΩ. Power Requirements : 24V DC ±10%
(standard spec.) as well as 1kΩ. (Auto determinant function). Power Consumption : 0.6VA max
o
• pH temperature compensation: Ambient Conditions : -20~55 C, 99%RH or less
Compensates pH temperature characteristics of samples (pure Construction : Outdoor installation, dust/rainproof
water & boiler water). Temperature setting range; Type (IP55)
0.100~+0.100pH/°C. Temperature for standard conversion; 25°C. Weight : Approx. 3kg
• Self diagnostics: Mounting : Mounted on 50A pipe
Detects damage on glass membrane, problems with temperature Cable Entry : G 3/4 (PF 3/4 F), 3 ports
compensation resistance, abnormal data and indicates fault by Materials
altering transmission output to higher or lower limit (adjustable). Main Body : Cast aluminium alloy
Note that damage on glass membrane is not detected when Window : Plastic
extension cable (EC-10) is in use. Colour : Metallic silver and blue

SYSTEM CONFIGURATION

Model: HDM-135A - 2-Wire Type pH Analyzer/Transmitter - Issue: HDM-135A-0209-R1 Page 1


DIMENSIONS
unit: mm

TERMINALS

Page 2 Model: HDM-135A - 2-Wire Type pH Analyzer/Transmitter - Issue: HDM-135A-0209-R1


WIRING DIAGRAMS

OPTIONAL ACCESSORIES

• Sun Shade (hood)


Recommended when the instrument is installed at a location
exposed to direct sunlight.
Material : SUS304
Mounting : 50A pipe

Model: HDM-135A - 2-Wire Type pH Analyzer/Transmitter - Issue: HDM-135A-0209-R1 Page 3


APPLICATION SENSORS

A wide variation of sensors can be combined with HDM-135A


transmitter as shown in the following table. Properly select the sensor
in accordance with limiting conditions such as immersion type, flow-
through type, wetted parts material, and measurement conditions.

o o
Note: All service temperature range of HF resistant electrode is –5 C~50 C

Page 4 Model: HDM-135A - 2-Wire Type pH Analyzer/Transmitter - Issue: HDM-135A-0209-R1


PRODUCT CODE

For other custom specifications, specify code


9 for numeric digit and code Z for
alphabetical digit.

*1. Output range is limited to [set at 0.1pH


step with min. range span of 2pH]

DKK-TOA CORPORATION Do not operate products before


consulting instruction manual.

International Operations:
DKK-TOA Corporation
29-10, 1-Chome, Takadanobaba, Shinjuku-ku, Tokyo 169-8648 Japan
Tel: +81-3-3202-0225 Fax: +81-3-3202-5685

Representative Office (Europe):


DKK-TOA European Representative
St. Johns Innovation Centre, Cowley Rd., Cambridge CB4 0WS UK.
Tel : +44 (0)1223-526471 Fax : +44 (0)1223-709239

http://www.toadkk.co.jp Information and specifications are for a typical system and are subject to change without notice.