Download as pdf
Download as pdf
You are on page 1of 8
Product Catalogue MCB, RCCB General (6A to 40A) ce © ¢@B Miniature Circuit Breaker 1. Certificates : CE, SEMKO 2, Electric rating: up to 60A, 400V; AC 50/60Hz; 3. Tripping characteristics: B,C,D 4, on:3000A/4500A/6000A; 5. Rated insulation voltage Ui:500V 6. Rated impulse withstand voltage Uimp: 4000V; 7. Life (Operations): a. Electric life: = 4000 b. Mechanical life: = 10000 8. Ambient temperature: -5°C ~+40°C 9. Standard: IEC/EN 60898-1 Features 1. Improved creep page distance 2. Better heat dispensation capability due to the re-designed enclosure 3. Greater conductivity through material change of the connection screw 4. Compact design, swift tripping and long service life; 5. Verified breaking capacity for your carious demands. cece Me © GOOCSRCEAN NB1 Miniature Circuit Breaker General (50A to 63A) 1. Certificates: ‘AC operation: CB,CE,ESC,FIMKO,SEMKO, UKREST, PCT,RCC,CSA, Indonesia Certificate, SNK; 2. Electric Ratings: a. AC, up to 63A, AC 230/400V, ACSO/60Hz, applicable to iP, 2P, 3P, 4P; Icn = 6000A/1000A : B.C, D type b. DC: up to 63A, DC 110V/iP, DC125V/2P, applicable to 1P, 2P Ion = 10000A; B.C type ¢. UL1077: AC277/480V, applicable to lon = 5kA, 1~63A, B,C type 1P, 2P, SP, 4P 3. Tripping characteristic: a. AC operation: B(3-5)In, C(5-10)In, D(10-14)In; b. DC operation: B(4-7)In, C(7-15)In; . B curve: for a common generator; C curve: standard supply a small short-circuit current; D curve: when the starting current is high. Rated insulation voltage Ui: 500V; Rated impulse withstand voltage Uimp:6000V Energy limiting class: 3; Ambient temperature Storage temperate: Accessories Combination with accessories The breaker could be combined with XF9 auxiliary contact, S9 shunt tip and V9 under-voltage trip to expand the operation functions. PNooe NBA + xFO NBt + V9 x9) Description | auxiliary contact lUnder-voltage releaso| Alarm auxiliary Bt + busbar Aepcaton | Sinating | Remoteconua | ,Pipecton ages, | signa iricaton Features 1. Much higher short circuit breaking capacity. 2. Dual — connection convenient for both standard busbar and cable connection. 3. Improved safety of operators offered by special design of terminals. 4. Much longer service life thanks to energy — storage operating mechanism. 5. A variety of modular auxiliaries allows for easy and quick installation. 6. Enclosure and functional parts made of advanced plastics with flame ~ retardant, heat ~ resistant and impulse — proof properties 7. Higher current. limiting capacity ensuring a cost ~ effective range of products 8. Indication window added in the front; handle becomes more comfortable 9. Optimized design makes the product a better appearance; certificate. Symbols printed ‘on the front will be moved to the side face through moulded processing measures. 10. Easier for mounting and replacement: better heat dissipation. 2 Bure 38 G88 G20c_. ous 888 88 Sy PITH wm eM UN Deurve 0.001 OS 1 23457 10 20303070700200 Vin 16'S EBMCB is of high current limiting performance to limit the destruction energy due to the greatest extent. Ccuve _~ se wid 889 &. os Vin OF TIT we ORD Current limiting curve Prospective peak valve Short crcit of short circuit current Prospective short incu ener Peak valueof current limit Short ereut energy of curent init NL1 Residual Current Operated Circuit Breaker General With Earth Fault Trip Indicator 1.Application: For protection against of fire due to live earth fault where faul insufficient to cause over-current protection device to operate. For protection against risk of shock from indirect contact with equipment suffering a live to earth fault. For protection against shock in potentially hazardous environment. As supplementary protection against shock from directly touching ‘LIVE’ parts. Note: an RCD must not be used as the sole means of protection against touching live parts. 2.General rules for choosing RCD: a.Rated residual operating current 10mA ~ to give a high degree of protection against shock in a hazardous environment situation where supplementary protection against shock from accidental direct contact is required. 30mA — to give a high degree of protection against electric shock in a situation where supplementary protection against shock from accidental direct contact is required when it must be able to trip within 40 milliseconds when a fault current of 150mA is detected 100 mA — to give @ degree of protection against electric shock due to indirect contact situation. 300 mA — to give overall protection against risk of fire from electrical faults in wiring etc, only Where sufficient current (Iypically less than 500 mA) may cause incandescence of metal parts in suitable circumstances and in consideration that installed over current devices would require far in excess of 300 mA to operate. b.Tripping class AC class ~ Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase, class — Tripping in ensured for sinusoidal , alternating residual currents as well as for pulsed DC currents, whether they be quickly applied or slowly increase. Technical features STANDARD IEC/EN 6108-1 ‘Type (wave form of the earth leakage sensed) ACA Rated Curent in A. | 25.40.63 Poles 2P4P Rated votage Us Vv | 230/400 Rated sensitivity lan A | 0.03,0.1,0.3 Insulation voltage Ui Vv | 500 Rated residual making and ‘500(in = 25A/40A) breaking capacity lam A. | 630(in = 63A) Electrical | Rated condtional short-circuit curent ine ‘A | 6000/1000 Features | Rated residual making and breaking capacty Isc | A | 6000/10000 break time under lan 8 | 04 Rated frequency Hz | 50/60 Rated impuised withstand votage(1.250) Uimp | V | 6000 Dielectric test voltage at ind.Freq, for 1 min kv | 25 Electialifo 2,000 2,000(In = 25) ‘Mechanical fe 1/000 (In = 40A/63A) Mechanical Fault curentindicator Yes Features: Protection degree P50 “Ambient temperature (with daily average = 35°C) cc | -5.... 440 ‘Storage temperation °C | -25...470 ‘Terminal connection ype Cable/U-type busbar/Pin-type busbar “Terminal size tpibotton for cable mm# | 25 Installation | Terminal size toprbotiom for busbar AWG | 18-3 mm? | 25 Tiphtoning torque AWG | 18.3 Nim | 25 Mounting Inds. | 22 ‘Connection ‘On Din rail EN 60715 (35mm) by mean Of fast dip device From top and bottom # NL1, 2P 14c=10000A OE NL1, 4P 14c=10000A erode) = )_72mm Tian | er Code : (Atype AC! 1a) coma) [OTN a 40 | 30. | 0 | oe4e02|oedoor wo | 30. | 46 | se4oz2|aes0a7 40 | 100 | 00 | ae4ees | 24008 40 | 100 | 45 | ee4oas |oedoae 40, 300 | 90 | 984894 | 984909) a 300 | 45 | 984924 | 984939 63 | 20 | 90 | ae4o9s |se4910 63 | 90. | 45 | ee4oas |aeso40 a | 1007 | 20 | 06 |seaas1 3 | 100 | 45 | sodas |aesoat 63_|_a00 | 20 | sexeo7 |se4912 3_| 300 | 45 | oe4sz7 |ossowa GED em Certificate © emma roactsany KEMAX CERTIFICATE CHNT Zhejiang CHINT Electrics Co., Ltd. Tel 1 +86-S87-6277777TT 62877777 Fax: +86-577-62775796 62871811 Add: CHINT High-tech Industrial Zone, North Baixiang, Wenzhou. Zhejiang Province, P.R China 325603 Email: global-sales@chint.com Website : wanw.chint.com

You might also like