Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

STUDOR P.A.P.A.

® TM

Positive Air Pressure Attenuator

The P.A.P.A.TM is a device used to


eliminate the harmful effects of positive transients generated in
gravity fed systems in multi-storey buildings

Installation of the P.A.P.A.


TM

The P.A.P.A. is provided with a rubber connector on the II) Installation of a Maxi-Vent on top of the P.A.P.A. :
TM TM TM

base and with a separate O-ring and male thread adapter


a) fit O-ring to the male thread adapter;
to allow greater versatility.
b) fit the male thread adapter to the base of the
Maxi-Vent and glue into place sparingly using
TM

1 2 3 ABS solvent;
c) wipe away any excess solvent to ensure this does
Rubber connector O-ring Male thread adapter
not get into the Maxi-Vent , as this will affect its
TM

operation;

I) Installation of the P.A.P.A. with the rubber connector:


TM

a) ensure the rubber connector is


securely fitted to the base of the
P.A.P.A. ;
TM

b) 3 c)

a) 2

d) unscrew the cap on the top of the P.A.P.A. ;


TM

e) when the solvent has fully dried, screw the male


thread adapter fitted to the base of the
Maxi-Vent into the top of the P.A.P.A.
TM TM

d) e)
1 1

a) 1 b)
75mm 110mm

b) push-fit the rubber connector fitted


to the base of the P.A.P.A. onto
TM

a 75mm or into a 110mm pipe


connection.
STUDOR P.A.P.A.
® TM

Positive Air Pressure Attenuator

k)

III) Installation of the P.A.P.A. in series:


TM

a) up to four P.A.P.A. s may be installed in series;


TM

b) ensure the rubber connector is securely fitted to the base of the bottom-most
P.A.P.A. ;
TM

c) push-fit the rubber connector fitted to the base of this P.A.P.A. onto a
TM

75mm or into a 110mm pipe connection;


d) unscrew the cap on the top of this P.A.P.A.
TM

e) remove the rubber connector fitted to the base of the next P.A.P.A. to be
TM

installed;
f) fit O-ring to the male thread adapter;
g) fit the male thread adapter to the base of this P.A.P.A. and glue into
TM

place sparingly using ABS solvent;


h) wipe away any excess solvent;
i) when the solvent has fully dried, screw the male thread adapter fitted to the
base of this P.A.P.A. into the top of the bottom-most P.A.P.A. ;
TM TM

j) repeat steps d) to i) up to a MAXIMUM of four P.A.P.A. s;


TM

k) ensure the cap of the top P.A.P.A. is securely screwed in, or replace with
TM
g) 3
g) 3
a Maxi-Vent as described in II) overleaf.
TM

f) 2 f) 2

IV) Installation of the P.A.P.A.


TM
horizontally:

a) when a Maxi-Vent is NOT used the P.A.P.A. may be installed horizontally;


TM TM

ensure the rubber connector is securely fitted to the base of the P.A.P.A. ;
TM

b) push-fit the rubber connector fitted to the base of the P.A.P.A. onto a 75mm or TM

c) into a 110mm 'T' pipe connection into the stack using a 45 degree 'T' joint on the
stack and a 45 degree bend to place the P.A.P.A. into a horizontal position -
TM

this prevents water penetrating the unit.

c)

45 angle
1

b)

1 1 support strut
b) b)

c) c)
75mm 110mm
For extra security it is recommended that
the P.A.P.A. is secured to an adjacent
TM

pipe or support strut using a pipe clip or


clamp.

For more information please visit www.studor.net or email studor.info@aliaxis.com