7/32” (5.69 mm)


MONOCONDUCTOR
HIGH STRENGTH
1K22P – HS

PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.2 ft/Kft/Klbs (2.50 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 4.3 Ω/Kft (14.1 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,600 lbs (24.9 KN) Nominal
Maximum Suggested Working Tension: 2,800 lbs (12.5 KN)
Number and Size of Wires:
Inner Armor 15 x 0.0243” (0.617 mm)
Outer Armor 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 132 lbs (0.59 KN)
Outer Armor 286 lbs (1.27 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In in Ω /Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1K22PP–HS 300 Poly 0.0245 19x0.0119 4.0 60 0.108 91 75
149 0.622 19x0.302 13.1 197 2.743 136 112
1K22PXZ–HS 420 Camtane 0.0130 19x0.0119 4.0 61 0.085 92 76
216 0.330 19x0.302 13.1 200 2.159 137 114
ETFE 0.0115 0.108
0.292 2.743
1K22PA–HS 500 PFA 0.0245 19x0.0119 4.0 56 0.108 95 78
260 0.622 19x0.302 13.1 184 2.743 141 116
1K22PTZ–HS 500 FEP 0.0130 19x0.0119 4.0 58 0.085 94 78
260 0.330 19x0.302 13.1 190 2.159 140 116
ETFE 0.0115 0.108
0.292 2.743

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 2 23–July–10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342– 0531
9

7/32” (5.69 mm)


MONOCONDUCTOR
1K22 – S75
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.7 ft/Kft/Klbs (3.0 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 16.0 Ω/Kft (52.5 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,700 lbs (20.9 KN) Nominal

Maximum Suggested Working Tension: 2,350 lbs (10.5 KN)


Number and Size of Wires:
Inner Armor 15 x 0.0243” (0.617 mm)
Outer Armor 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 111 lbs (0.50 KN)
Outer Armor 242 lbs (1.10 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1K22SA – S75 PFA 0.0305 7x0.0159 6.7 43 0.108 95 78
See
7x0.404 22.0 141 2.743 142 117
Bellow 0.775

∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 deg. F at low exposure to H2S + CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent; is applied between armor layers.
∗ The insulation temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23– July – 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
11

7/32” (5.69 mm)


MONOCONDUCTOR
1K22 – MP35N
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.9 ft/Kft/Klbs (3.30 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 22.0 Ω/Kft (72.2 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,200 lbs (23.0 KN) Nominal
Maximum Suggested Working Tension: 2,600 lbs (11.6 KN)
Number and Size of Wires:
Inner Armor 15 x 0.0243” (0.617 mm)
Outer Armor 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 125 lbs (0.56 KN)
Outer Armor 272 lbs (1.21 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thicknes Construction Typical Typical Each Air H2O
s
°F in in Ω/Kft pf/ft In lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1K22SA – MP35N 500 0.0305 7x0.0159 6.7 43 0.108 100 86
PFA
260 0.775 7x0.404 22.0 141 2.743 149 128

∗ The armor wires are made of UNS R30035 (MP35N), a nickel-cobalt corrosion resistant alloy steel and coated with
anti-corrosion compound for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23 – July – 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
10

7/32” (5.69 mm)


MONOCONDUCTOR
1K22 – S77
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 3.0 ft/Kft/Klbs (3.4 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 18.5 Ω/Kft (60.7 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,900 lbs (21.8 KN) Nominal
Maximum Suggested Working Tension: 2,450 lbs (10.9 KN)
Number and Size of Wires:
Inner Armor 15 x 0.0243” (0.617 mm)
Outer Armor 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 116 lbs (0.52 KN)
Outer Armor 252 lbs (1.12 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In in Ω/Kft pf/ft in lbs/Kft
°C Mm mm Ω/Km pf/m mm Kg/Km
1K22SA–S77 See 0.0305 7x0.0159 6.7 43 0.108 94 80
PFA
Bellow 0.775 7x0.404 22.0 141 2.743 140 119

∗ Insulation is rated to 500 deg. F. Armor wires are rated to 425 deg, F, at medium levels of H2S & CO2
∗ The armor wires are made of UNS S31277, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23–July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342–0531
7

3/16” (4.70 mm)


MONOCONDUCTOR
1L18

PROPERTIES:
Cable Diameter: 0.185” +0.004” -0.002” (4.70mm + 0.10mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 3.0 ft/Kft/Klbs (3.37 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,000 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC
Armor Electrical Resistance: 6.0 Ω/Kft (19.7 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,000 lbs (17.8 KN) Nominal
Maximum Suggested Working Tension: 2,000 lbs (8.9 KN) Nominal
Number and Size of Wires:
Inner Armor 12 x 0.0220” (0.559 mm)
Outer Armor 12 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 103 lbs (0.46 KN)
Outer Armor 272 lbs (1.21 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In in Ω /Kft pf/ft In lbs/Kft
°C Mm mm Ω/Km pf/m mm Kg/Km

1L18RP 300 Poly 0.019 7x0.0128 9.4 53 0.076 65 54


149 0.483 7x0.325 30.8 174 1.930 97 80
1L18RZ 500 ETFE 0.019 7x0.0128 9.4 63 0.076 66 55
260 0.483 7x0.325 30.8 207 1.930 99 81

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 2 23 –July – 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
5

1/10” (2.56 mm)


MONOCONDUCTOR
1N10

PROPERTIES:
Cable Diameter: 0.101” +0.004” -0.002” (2.56mm + 0.10mm -0.05mm)
Minimum Shave Diameter: 6” (15 cm)
Cable Stretch Coefficient 13.1 ft/Kft/Klbs (14.72 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 300 VDC
Conductor AWG Rating 24
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 22.0 Ω/Kft (72.2 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 1,000 lbs (4.4 KN) Nominal
Maximum Suggested Working Tension: 500 lbs (2.2 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0140” (0.356 mm)
Outer Armor 18 x 0.0140” (0.356 mm)
Average Wire Breaking Strength:
Inner Armor 42 lbs (0.19 KN)
Outer Armor 42 lbs (0.19 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In in Ω/Kft pf/ft in lbs/Kft
°C Mm mm Ω/Km pf/m mm Kg/Km
1N10RP 300 Poly 0.012 7x0.0085 21.0 51 0.049 19 15
149 0.305 7x0.216 69.0 167 1.244 28 23

• The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
• Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at
68 deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
• SUPERSEAL a special pressure seal agent, is applied between armor layers.
• The temperature rating assumes a normal gradient for both temperature and weight.
• All values shown are nominal or typical values.

Rev: 2 23-July – 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
6

1/8” (3.20 mm)


MONOCONDUCTOR
1N12

PROPERTIES:
Cable Diameter: 0.126” +0.004” -0.002” (3.20mm + 0.10mm -0.05mm)
Minimum Shave Diameter: 7” (18 cm)
Cable Stretch Coefficient 6.5 ft/Kft/Klbs (7.30 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 300 VDC
Conductor AWG Rating 24
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 13.0 Ω/Kft (42.6 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 1,600 lbs (7.1 KN) Nominal
Maximum Suggested Working Tension: 800 lbs (3.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0175” (0.444 mm)
Outer Armor 18 x 0.0175” (0.444 mm)
Average Wire Breaking Strength:
Inner Armor 65 lbs (0.29 KN)
Outer Armor 65 lbs (0.29 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N12RP 300 Poly 0.0175 7x0.0085 21.0 41 0.060 28 23
149 0.444 7x0.216 69.0 134 1.524 42 35
1N12RZ 500 ETFE 0.0175 7x0.0085 21.0 48 0.060 29 24
260 0.444 7x0.216 69.0 157 1.524 43 36

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 2 23-July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
12

7/32” (5.69 mm)


MONOCONDUCTOR
HIGH STRENGTH
1N22 - HS

PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 2.5 ft/Kft/Klbs (2.81 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 4.4 Ω/Kft (14.4 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,600 lbs (24.9 KN) Nominal
Maximum Suggested Working Tension: 2,800 lbs (12.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 215 lbs (0.96 KN)
Outer Armor 215 lbs (0.96 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in In
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F in in Ω /Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N22PP–HS 300 Poly 0.0245 19x0.0119 4.1 58 0.108 93 77
149 0.622 19x0.302 13.5 190 2.743 139 115
1N22PXZ–HS 420 Camtane 0.0130 19x0.0119 4.1 59 0.085 95 80
216 0.330 19x0.302 13.5 194 2.159 141 119
ETFE 0.0115 0.108
0.292 2.743
1N22PTZ–HS 500 FEP 0.0130 19x0.0119 4.1 58 0.085 96 80
260 0.330 19x0.302 13.5 190 2.159 143 119
ETFE 0.0115 0.108
0.292 2.743
1N22PA–HS 500 PFA 0.0245 19x0.0119 4.1 55 0.108 97 80
0.622 19x0.302 13.5 180 2.743 144 119

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
14

7/32” (5.69 mm)


MONOCONDUCTOR
1N22 – S77
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.224” +0.005” – 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 3.1 ft/Kft/Klbs (3.5 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 18.1 Ω/Kft (59.4 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,900 lbs (21.8 KN) Nominal
Maximum Suggested Working Tension: 2,450 lbs (10.9 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 189 lbs (0.84 KN)
Outer Armor 189 lbs (0.84 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in In
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In In Ω/Kft pf/ft In Lbs/Kft
°C Mm Mm Ω/Km pf/m Mm Kg/Km
1N22SA – S77 See PFA 0.0305 7x0.0159 6.7 43 0.108 97 81
Bellow 0.7747 7x0.404 22.0 141 2.743 144 119

∗ Insulation is rated to 500 deg. F. Armor wires are rated to 425 F at medium levels of H2S & CO2.
∗ The armor wires are made of UNS S31277, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23–July –10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494; Fax (281) 342 – 0531
15
7/32” (5.69 mm)
MONOCONDUCTOR
1N22 - MP35N
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 2.9 ft/Kft/Klbs (3.30 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 22.0 Ω/Kft (72.2 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,200 lbs (23.0 KN) Nominal

Maximum Suggested Working Tension: 2,600 lbs (11.6 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 204 lbs (0.91 KN)
Outer Armor 204 lbs (0.91 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construc Typical Typical Each Air H2O
tion
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N22SA–MP35N 500 PFA 0.0305 7x0.0159 6.7 43 0.108 100 86
260 0.078 7x0.404 22.0 141 2.743 149 128

∗ The armor wires are made of UNS R30035 (MP35N), a nickel-cobalt corrosion resistant alloy steel and coated with
anti-corrosion compound for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23 – July–10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Facsimile (281) 342 - 0531
13

7/32” (5.69 mm)


MONOCONDUCTOR
1N22 - S75
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.224” +0.005” – 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 3.1 ft/Kft/Klbs (3.5 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 18
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 18.1 Ω/Kft (59.4 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 4,700 lbs (20.9.0 KN) Nominal
Maximum Suggested Working Tension: 2,350 lbs (10.5 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 181 lbs (0.81 KN)
Outer Armor 181 lbs (0.81 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In In Ω/Kft pf/ft In Lbs/Kft
°C Mm Mm Ω/Km pf/m Mm Kg/Km
1N22SA – S75 See PFA 0.0305 7x0.0159 6.7 43 0.108 98 81
Bellow 0.775 7x0.404 22.0 141 2.743 145 120

∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 F at low levels of H2S & CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23 –July –10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494; Fax (281) 342 – 0531
7/32” (5.69 mm)
MONOCONDUCTOR
1N22

PROPERTIES:
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 13” (33 cm)
Cable Stretch Coefficient 2.5 ft/Kft/Klbs (2.81 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 4.4 Ω/Kft (14.4 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 5,200 lbs (23.1 KN) Nominal

Maximum Suggested Working Tension: 2,600 lbs (11.6 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0310” (0.787 mm)
Outer Armor 18 x 0.0310” (0.787 mm)
Average Wire Breaking Strength:
Inner Armor 204 lbs (0.91 KN)
Outer Armor 204 lbs (0.91 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N22SWFE 600 PTFE 0.0245 19x0.0119 4.7 58 0.108 97 80
316 0.622 19x0.404 22.0 190 2.743 144 119
1N22SWSE 600 HSTF 0.0245 19x0.0119 4.7 58 0.108 97 80
316 0.622 19x0.404 22.0 190 2.743 144 119

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F.
∗ SUPERSEAL; a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev. 0; prototype phase August – 09

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
16

1/4” (6.55 mm)


MONOCONDUCTOR
1N25

PROPERTIES:
Cable Diameter: 0.258” +0.005” - 0.002” (6.55mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 1.9 ft/Kft/Klbs (2.13 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 3.0 Ω/Kft (9.84 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 7,000 lbs (31.1 KN) Nominal
Maximum Suggested Working Tension: 3,500 lbs (15.6 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0358” (0.909 mm)
Outer Armor 18 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 272 lbs (1.21 KN)
Outer Armor 272 lbs (1.21 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In In Ω /Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N25PP 300 Poly 0.032 19x0.0119 4.1 50 0.123 121 100
149 0.813 19x0.302 13.5 164 3.124 180 149
1N25PXZ 420 Camtane 0.0130 19x0.0119 4.1 53 0.085 124 101
216 0.330 19x0.302 13.5 174 2.159 185 151
ETFE 0.019 0.123
0.483 3.124
1N25PTZ 500 FEP 0.0130 19x0.0119 4.1 53 0.085 125 103
260 0.330 19x0.302 13.5 174 2.159 186 154
ETFE 0.019 0.123
0.483 3.124
1N25PA 500 PFA 0.032 19x0.0119 4.1 52 0.123 126 104
260 0.813 19x0.302 13.5 171 3.124 188 155

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL;,a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
17
1/4” (6.55 mm)
MONOCONDUCTOR
1N25 – S75
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.258” +0.005” – 0.002” (6.55mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.3 ft/Kft/Klbs (2.60 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 16.5 Ω/Kft (54.13 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 6,000 lbs (26.7 KN) Nominal

Maximum Suggested Working Tension: 3,000 lbs (13.3 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0358” (0.909 mm)
Outer Armor 18 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 242lbs (1.10 KN)
Outer Armor 242 lbs (1.10 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thicknes Construction Typical Typical Each Air H2O
s
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N25WA–S75 See PFA 0.032 19x0.0119 4.6 53 0.123 127 102
Bellow 0.081 19x0.302 14.4 174 3.124 189 154

∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 F at low levels of H2S & CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23–July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Facsimile (281) 342 - 0531
18

1/4” (6.55 mm)


MONOCONDUCTOR
1N25 – S77
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.258” +0.005” - 0.002” (6.55mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 14” (36 cm)
Cable Stretch Coefficient 2.3 ft/Kft/Klbs (2.60 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,200 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 10.0 Ω/Kft (32.9 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 6,500 lbs (28.9 KN) Nominal

Maximum Suggested Working Tension: 3,250 lbs (14.5 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0358” (0.909 mm)
Outer Armor 18 x 0.0358” (0.909 mm)
Average Wire Breaking Strength:
Inner Armor 252lbs (1.12 KN)
Outer Armor 252lbs (1.12 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In In Ω/Kft pf/ft in lbs/Kft
°C Mm Mm Ω/Km pf/m mm Kg/Km
1N25WA – S77 See PFA 0.032 19x0.0119 4.6 53 0.123 129 106
Bellow 0.081 19x0.302 15.1 174 3.124 191 158

∗ Insulation is rated to 500°F, Armor wires are rated to 425°F at medium levels of H2S+CO2.
∗ The armor wires are made of UNS S31277, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F.
Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent; is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23– July – 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
19

9/32” (7.32 mm)


MONOCONDUCTOR
1N29 – EHS
EXTRA HIGH
STRENGTH

PROPERTIES:
Cable Diameter: 0.288” +0.005” - 0.002” (7.32mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 16” (41 cm)
Cable Stretch Coefficient 1.55 ft/Kft/Klbs (1.74 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.8 Ω/Kft (9.2 Ω/Km)

MECHANICAL:
Cable Breaking Strength: 10,200 lbs (45.4 KN) Nominal

Maximum Suggested Working Tension: 5,100 lbs (22.7 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0400” (1.016 mm)
Outer Armor 18 x 0.0400” (1.016 mm)
Average Wire Breaking Strength:
Inner Armor 393 lbs (1.75 KN)
Outer Armor 393 lbs (1.75 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Resistance Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F in in Ω /Kft pf/ft In lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
300 Poly 0.0325 19x0.0142 2.8 56 0.136 152 125
1N29PP-EHS
149 0.826 19x0.361 9.2 184 3.454 226 187
0.0135 0.098
FEP
500 0.343 19x0.0142 2.8 55 2.489 157 130
1N29PTZ–EHS
260 0.019 19x0.361 9.2 177 0.136 234 193
ETFE
0.483 3.454
500 0.0325 19x0.0142 2.8 51 0.136 159 131
1N29PA–EHS PFA
260 0.826 19x0.361 9.2 167 3.454 237 196

∗ The armor wires are Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for protection
during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, it is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
∗ Not recommended for use in any sour and / or corrosive environment.
Rev. 02 23–July–10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 – 0531
20

9/32” (7.32 mm)


MONOCONDUCTOR
1N29 – S75
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.288” +0.005” – 0.002” (7.32mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 16” (41 cm)
Cable Stretch Coefficient 1.9 ft/Kft/Klbs (2.13 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 16
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 10.0 Ω/Kft (32.8 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 7800 lbs (34.7 KN) Nominal
Ends Free:
Maximum Suggested Working Tension: 3, 900 lbs (17.4 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0400” (1.016 mm)
Outer Armor 18 x 0.0400” (1.016 mm)
Average Wire Breaking Strength:
Inner Armor 302 lbs (1.34 KN)
Outer Armor 302 lbs (1.34 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In In Ω/Kft pf/ft In lbs/Kft
°C Mm mm Ω/Km pf/m Mm Kg/Km
1N29WA – S75 See PFA 0.036 19x0.0128 4.0 54 0.136 162 134
Bellow 0.914 19x0.325 13.1 177 3.454 241 199

∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 F at low levels of H2S & CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23–July– 10

CAMESA, INC. 1615 Spur 529 PO. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494; Fax (281) 342 – 0531
21

5/16” (8.18 mm)


MONOCONDUCTOR
HIGH STRENGTH
1N32 – HS

PROPERTIES:
Cable Diameter: 0.322” +0.005” - 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (46 cm)
Cable Stretch Coefficient 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed 11,400 lbs (50.7 KN) Nominal

Maximum Suggested Working Tension: 5,700 lbs (25.4 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0445” (1.130 mm)
Outer Armor 18 x 0.0445” (1.130 mm)
Average Wire Breaking Strength:
Inner Armor 442 lbs (1.97 KN)
Outer Armor 442 lbs (1.97 KN)
Cable Type Core Description Cable Weight
Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F in in Ω /Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N32PP- HS 300 Poly 0.042 19x0.0142 2.8 46 0.155 187 155
149 1.067 19x0.361 9.2 151 3.937 278 230
1N32PXZ- HS 420 Camtane 0.022 19x0.0142 2.8 47 0.115 189 157
216 0.560 19x0.361 9.2 154 2.921 282 233
ETFE 0.0200 0.155
0.508 3.937
1N32PTZ- HS 500 FEP 0.0245 19x0.0142 2.8 45 0.120 194 160
260 0.622 19x0.361 9.2 148 3.048 288 238
ETFE 0.0175 0.155
0.445 3.937

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPER SEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
22

5/16” (8.18 mm)


MONOCONDUCTOR
1N32P – LRHS
LOW RESISTANCE;
AND HIGH STRENGTH.

PROPERTIES:
Cable Diameter: 0.322” +0.005” – 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (46 cm)
Cable Stretch Coefficient 1.2 ft/Kft/Klbs (1.35 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 13
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.1 Ω/Kft (6.9 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 11,400 lbs (50.7 KN) Nominal

Maximum Suggested Working Tension: 5,700 lbs (25.4 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0445” (1.130 mm)
Outer Armor 18 x 0.0445” (1.130 mm)
Average Wire Breaking Strength:
Inner Armor 442 lbs (1.97 KN)
Outer Armor 442 lbs (1.97 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thicknes Construction Typical Typical Each Air H2O
s
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N32PTZ – LR-HS 500 FEP 0.017 19x0.0172 2.3 58 0.120 198 163
260 0.432 19x0.437 7.5 190 3.048 294 243
ETFE 0.018 0.155
0.444 3.937

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPER SEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23–July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
23

5/16” (8.18 mm)


MONOCONDUCTOR
1N32 – S75
CORROSION
RESISTANT

PROPERTIES:
Cable Diameter: 0.322” +0.005” – 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (45 cm)
Cable Stretch Coefficient 1.6 ft/Kft/Klbs (1.8 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 11.2 Ω/Kft (36.7 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 9,700 lbs (43.2 KN) Nominal

Maximum Suggested Working Tension: 4,850 lbs (21.6 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0445” (1.130 mm)
Outer Armor 18 x 0.0445” (1.130 mm)
Average Wire Breaking Strength:
Inner Armor 373.4 lbs (1.66 KN)
Outer Armor 373.4 lbs (1.66 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In in Ω/Kft pf/ft in lbs/Kft
°C Mm mm Ω/Km pf/m mm Kg/Km
1N32WTZ – S75 See FEP 0.0245 19x0.0142 3.2 45 0.120 201 166
Bellow 0.622 19x0.361 10.5 148 3.048 299 247
ETFE 0.0175 0.155
0.444 3.937

∗ Insulation is rated to 500 deg. F. Armor wires are rated to 325 F at low levels of H2S & CO2.
∗ The armor wires are made of UNS NO8926, a corrosion resistant alloy steel and coated with anti-corrosion compound
for protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68
deg. F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev: 02 23– July – 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
24

5/16” (8.18 mm)


MONOCONDUCTOR
1N32 – S77
CORROSION
RESISTANCE

PROPERTIES:
Cable Diameter: 0.322” +0.005” – 0.002” (8.18mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (46 cm)
Cable Stretch Coefficient 1.6 ft/Kft/Klbs (1.8 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 11.2 Ω/Kft (36.7 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 9,700 lbs (43.2 KN) Nominal

Maximum Suggested Working Tension: 4,850 lbs (21.6 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0445” (1.130 mm)
Outer Armor 18 x 0.0445” (1.130 mm)
Average Wire Breaking Strength:
Inner Armor 373.4 lbs (1.66 KN)
Outer Armor 373.4 lbs (1.66 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F In in Ω/Kft pf/ft in lbs/Kft
°C Mm mm Ω/Km pf/m mm Kg/Km
1N32WTZ–S77 See FEP 0.0245 19x0.0142 3.2 45 0.120 198 163
Bellow 0.622 19x0.361 10.5 148 3.048 294 243
ETFE 0.0175 0.155
0.444 3.937

∗ Insulation is rated to 500 deg. F. Armor wires are rated to 425 F at medium levels of H2S & CO2.
∗ The armor wires are made of UNS S31277, a corrosion resistant alloy steel and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ The nickel coated copper wires are made according the ASTMB355 Class 10 and they are used to increase corrosion
protection.
∗ Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68 deg.
F. Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev. 02 23 –July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
25

3/8” (9.65 mm)


MONOCONDUCTOR
1N38

PROPERTIES:
Cable Diameter: 0.380” +0.006” - 0.002” (9.65mm + 0.15mm -0.05mm)
Minimum Shave Diameter: 21” (53 cm)
Cable Stretch Coefficient 1.0 ft/Kft/Klbs (1.12 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 15
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.5 Ω/Kft (4.92 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed 15,000 lbs (66.7 KN) Nominal
Maximum Suggested Working Tension: 7,500 lbs (33.4 KN)
Number and Size of Wires:
Inner Armor 12 x 0.0525” (1.334 mm)
Outer Armor 18 x 0.0525” (1.334 mm)
Average Wire Breaking Strength:
Inner Armor 585 lbs (2.60 KN)
Outer Armor 585 lbs (2.60 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thickness Construction Typical Typical Each Air H2O
°F in In Ω /Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m Mm Kg/Km
1N38PP 300 Poly 0.056 19x0.0142 2.8 39 0.183 257 212
149 1.422 19x0.361 9.2 128 4.648 382 316
1N38PXZ 420 Camtane 0.027 19x0.0142 2.8 39 0.125 258 213
216 0.686 19x0.361 9.2 128 3.175 384 218
ETFE 0.029 0.183
0.737 4.648
1N38PTZ 500 FEP 0.027 19x0.0142 2.8 39 0.125 263 218
260 0.686 19x0.361 9.2 128 3.175 392 324
ETFE 0.029 0.183
0.737 4.648

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion compound for
protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F. Voids in the
copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL, a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.
Rev:02 23 –July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Facsimile (281) 342 - 0531
26

7/16” (10.80 mm)


MONOCONDUCTOR
1N42 – LRHS
LOW RESISTANCE
HIGH STRENGTH

PROPERTIES:
Cable Diameter: 0.425” +0.006” - 0.002” (10.80mm + 0.15mm -0.05mm)
Minimum Shave Diameter: 24” (61 cm)
Cable Stretch Coefficient 0.70 ft/Kft/Klbs (0.79 m/Km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1,500 VDC
Conductor AWG Rating 13
Minimum Insulation Resistance 1,500 MegaΩ/Kft @ 500VDC (457 MegaΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.2 Ω/Kft (3.94 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 19,500 lbs (86.8 KN) Nominal

Maximum Suggested Working Tension: 9,750 lbs (43.4 KN)


Number and Size of Wires:
Inner Armor 12 x 0.0585” (1.490 mm)
Outer Armor 18 x 0.0585” (1.490 mm)
Average Wire Breaking Strength:
Inner Armor 765 lbs (3.4 KN)
Outer Armor 765 lbs (3.4 KN)

Cable Type Core Description Cable Weight


Temp Plastic Type Copper Res Cap. O.D. in in
Rating Insulation Thicknes Construction Typical Typical Each Air H2O
s
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
1N42PTZ–LRHS 500 FEP 0.0255 19x0.0172 2.0 37.5 0.136 336 278
260 0.648 19x0.437 6.6 123 3.454 499 413
ETFE 0.035 0.206
0.890 5.232

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of a total of nineteen wires. Conductor resistance is measured at 68 deg. F.
Voids in the copper strand are filled with a water-blocking agent to reduce water and gas migration.
∗ SUPERSEAL a special pressure seal agent, is applied between armor layers.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev:02 23 –July– 10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax: (281) 342 - 0531
27

3/16” (4.80 mm)


4-CONDUCTOR
CABLE
4H18

PROPERTIES:
Cable Diameter: 0.186” +0.004” - 0.002” (4.80 mm + 0.10mm - 0.05mm)
Minimum Shave Diameter: 10” (25 cm)
Cable Stretch Coefficient 4.25 ft/Kft/Klbs (4.78 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 300 VDC
Conductor AWG Rating 23
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 6.7 Ω/Kft (22.0 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 3,100 lbs (13.8 KN) Nominal

Maximum Suggested Working Tension: 1,550 lbs ( 6.9 KN)

Number and Size of Wires:


Inner Armor 18 x 0.0185” (0.470 mm)
Outer Armor 18 x 0.0248” (0.630 mm)

Average Wire Breaking Strength:


Inner Armor 72 lbs (0.32 KN)
Outer Armor 130 lbs (0.58 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulat. Copper Res Cap. O.D. Jacket in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in In Ω /Kft pf/ft in lbs/Kft
°C mm Mm Ω/Km pf/m mm Kg/Km
4H18RPP 300 Poly 0.0075 7x0.0085 22.5 36 0.040 Poly 60 50
149 0.191 7x0.216 73.8 118 1.116 89 74

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed.
∗ Core assembly – Copper strand consists of six wires around one center wire. Voids in the copper strand are filled with
a water-blocking agent to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ All values shown are nominal or typical values.

Rev: 02 23–July– 10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax (281) 342-0531
28
5/16” (8.3mm)
7-CONDUCTOR

7H32

PROPERTIES:
Cable Diameter: 0.325” +0.005” - 0.002” (8.25mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 18” (45 cm)
Cable Stretch Coefficient 1.8 ft/Kft/Klbs (2.02 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1000 VDC
Conductor AWG Rating 22
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 2.3 Ω/Kft (7.5 Ω/Km)

MECHANICAL:

Cable Breaking Strength:


Ends Fixed: 9,500 lbs (42 KN) Nominal

Maximum Suggested Working Tension: 4,750 lbs (21 KN)

Number and Size of Wires:


Inner Armor 18 x 0.0320” (0.81 mm)
Outer Armor 18 x 0.0445” (1.13 mm)

Average Wire Breaking Strength:


Inner Armor 217 lbs (0.97 KN)
Outer Armor 420 lbs (1.99 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in in Ω/kft pf/ft In lbs/kft
°C mm mm Ω/km pf/m mm kg/km
7H32RP 300 Poly 0.013 7x0.0100 15.8 55 0.056 Dacron 183 152
149 0.33 7x0.254 51.8 180 1.42 272 226
7H32RZ 500 ETFE 0.013 7x0.0100 15.8 67 0.056 Dacron 188 157
260 0.33 7x0.254 51.8 220 1.42 280 234

• The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
• Core assembly – Conductors are bound with conductive tape and voids are filled with conductive filler and string.
Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
• The temperature rating assumes a normal gradient for both temperature and weight.
• Center conductor construction is 7×0.0100”. The typical resistance is reduced by approximately 5 to 10% and the
capacitance is increased by approximately 5 to 10% in comparison to the outer conductors.
• All values shown are nominal or typical values.
Rev: 02 23-July-10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 777471 Phone (281)342-4494 Facsimile (281) 342-0531
30
7/16” (10.82mm)
7-CONDUCTOR

7H42–HS

PROPERTIES:
Cable Diameter: 0.426” +0.005” - 0.002” (10.82mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 24” (61 cm)
Cable Stretch Coefficient 0.75 ft/Kft/Klbs (0.84 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1000 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.2 Ω/Kft (3.9 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 17,600 lbs (78.3 KN) Nominal
Maximum Suggested Working Tension: 8800 lbs (39.2 KN)

Number and Size of Wires:


Inner Armor 18 x 0.0425” (1.080 mm)
Outer Armor 18 x 0.0585” (1.490 mm)
Average Wire Breaking Strength:
Inner Armor 403.6 lbs (1.80 KN)
Outer Armor 764.6 lbs (3.4 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
7H42RP–HS 300 Poly 0.018 7x0.0128 9.8 53 0.074 Dacron 309 256
149 0.457 7x0.325 32.2 174 1.880 460 380
7H42RZ–HS 500 ETFE 0.018 7x0.0128 9.8 62 0.074 Dacron 318 263
260 0.457 7x0.325 32.2 203 1.880 473 391

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 7×0.0128”. The typical capacitance is decreased by approximately 5 to 10% in
comparison to the outer conductors.
∗ All values shown are nominal or typical values.

Rev: 02 23–July– 10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax (281) 342-0531
33
0.474” (12.0mm)
7-CONDUCTOR
Extra High
Strength
7H47–EHS
PROPERTIES:
Cable Diameter: 0.474” +0.005” - 0.002” (12.04mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 26” (66 cm)
Cable Stretch Coefficient 0.61 ft/Kft/Klbs (0.69 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1100 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.1 Ω/Kft (3.6 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 24,500 lbs (109 KN) Nominal

Maximum Suggested Working Tension: 12,250 lbs (55 KN)

Number and Size of Wires:


Inner Armor 18 x 0.0470” (1.194 mm)
Outer Armor 18 x 0.0655” (1.664 mm)

Average Wire Breaking Strength:


Inner Armor 542 lbs (2.4 KN)
Outer Armor 1054 lbs (4.7 KN)
Cable Type Core Description Cable Weight
Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in in Ω/kft pf/ft In lbs/kft
°C mm mm Ω/km pf/m mm kg/km
7H47RP–EHS 300 Poly 0.023 7x0.0128 9.8 46 0.084 Dacron 372 308
149 0.58 7x0.325 32.2 151 2.13 554 458
7H47RXZ–EHS 420 Camtane 0.0115 7x0.0128 9.8 48 0.061 Dacron 379 313
216 0.292 7x0.325 32.2 157 1.549 564 465
ETFE 0.0115 0.084
0.292 2.134
7H47RTZ–EHS 500 FEP 0.0115 7x0.0128 9.8 46 0.063 Dacron 392 326
260 0.292 7x0.325 32.2 151 1.60 583 485
ETFE 0.0115 0.084
0.292 2.13
• The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
• Core assembly – Conductors are bound with conductive tape and voids are filled with conductive filler and string.
Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
• The temperature rating assumes a normal gradient for both temperature and weight.
• Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors.
• All Values shown are nominal or typical values.
Rev:02 23-July-10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281)342-4494 Fax. (281) 342-0531
33
0.474” (12.0mm)
7-CONDUCTOR
Extra High
Strength
7H47–EHS
PROPERTIES:
Cable Diameter: 0.474” +0.005” - 0.002” (12.04mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 26” (66 cm)
Cable Stretch Coefficient 0.61 ft/Kft/Klbs (0.69 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1100 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.1 Ω/Kft (3.6 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 24,500 lbs (109 KN) Nominal

Maximum Suggested Working Tension: 12,250 lbs (55 KN)

Number and Size of Wires:


Inner Armor 18 x 0.0470” (1.194 mm)
Outer Armor 18 x 0.0655” (1.664 mm)

Average Wire Breaking Strength:


Inner Armor 542 lbs (2.4 KN)
Outer Armor 1054 lbs (4.7 KN)
Cable Type Core Description Cable Weight
Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in in Ω/kft pf/ft In lbs/kft
°C mm mm Ω/km pf/m mm kg/km
7H47RP–EHS 300 Poly 0.023 7x0.0128 9.8 46 0.084 Dacron 372 308
149 0.58 7x0.325 32.2 151 2.13 554 458
7H47RXZ–EHS 420 Camtane 0.0115 7x0.0128 9.8 48 0.061 Dacron 379 313
216 0.292 7x0.325 32.2 157 1.549 564 465
ETFE 0.0115 0.084
0.292 2.134
7H47RTZ–EHS 500 FEP 0.0115 7x0.0128 9.8 46 0.063 Dacron 392 326
260 0.292 7x0.325 32.2 151 1.60 583 485
ETFE 0.0115 0.084
0.292 2.13
• The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
• Core assembly – Conductors are bound with conductive tape and voids are filled with conductive filler and string.
Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
• The temperature rating assumes a normal gradient for both temperature and weight.
• Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors.
• All Values shown are nominal or typical values.
Rev:02 23-July-10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281)342-4494 Fax. (281) 342-0531
0.474” (12.04mm)
7-CONDUCTOR

7H47RA-HSN

PROPERTIES:
Cable Diameter: 0.474” +0.005” - 0.002” (12.04mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 26” (66 cm)
Cable Stretch Coefficient 0.61 ft/Kft/Klbs (0.69 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1100 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.1 Ω/Kft (3.6 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 23,600 lbs (105 KN) Nominal

Maximum Suggested Working Tension: 11,050 lbs (49.2 KN)

Number and Size of Wires:


Inner Armor 18 x 0.0470” (1.194 mm)
Outer Armor 18 x 0.0655” (1.664 mm)

Average Wire Breaking Strength:


Inner Armor 493 lbs (2.09 KN)
Outer Armor 958 lbs (4.05 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F In in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
7H47RA-HSn 500 PFA 0.023 7x0.0128 9.8 **44 0.084 Nomex 390 323
260 0.584 7x0.325 32.2 144 2.13 581 480

• The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
• Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
• Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg.
F.
• The temperature rating assumes a normal gradient for both temperature and weight.
• Center conductor construction is 6×0.0142” with a non-conductive center member and insulated with PFA. The
typical resistance is 9.2 Ω/Kft and the typical Capacitance could be from 44 to 48 pF/ft.
**The value of the typical capacitance could be with a variation From 42 to 46 pF/ft.

Rev. 00 Prototype Phase February- 10

CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax (281) 342-0531
31

15/32” (11.79mm)
7-CONDUCTOR
7J46

PROPERTIES:
Cable Diameter: 0.464” +0.005” - 0.002” (11.79mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 20” (51 cm)
Cable Stretch Coefficient 0.77 ft/Kft/Klbs (0.87 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.3 Ω/Kft (4.3 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 18,000 lbs (80.1 KN) Nominal
Maximum Suggested Working Tension: 9,000 lbs (40.0 KN)

Number and Size of Wires:


Inner Armor 24 x 0.0390” (0.991 mm)
Outer Armor 24 x 0.0495” (1.257 mm)

Average Wire Breaking Strength:


Inner Armor 340 lbs (1.51 KN)
Outer Armor 547 lbs (2.44 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
7J46RP 300 Poly 0.029 7x0.0128 9.8 40 0.096 Dacron 321 265
149 0.737 7x0.325 32.2 131 2.438 478 395
7J46RXZ 420 Camtane 0.016 7x0.0128 9.8 40 0.070 Dacron 340 281
216 0.406 7x0.325 32.2 131 1.778 507 419
0.013 0.096
ETFE 0.330 2.438
7J46RTZ 500 FEP 0.016 7x0.0128 9.8 39 0.070 Dacron 341 282
260 0.406 7x0.325 32.2 128 1.778 507 419
0.013 0.096
ETFE 0.330 2.438
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are postg tensioned.
∗ Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors.
∗ All values shown are nominal or typical values.
Rev: 02 23-July- 10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax: (281) 342-0531
32
15/32” (11.79mm)
7-CONDUCTOR
High Strength
7J46 - HS

PROPERTIES:
Cable Diameter: 0.464” +0.005” - 0.002” (11.79mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 20” (51 cm)
Cable Stretch Coefficient 0.77 ft/Kft/Klbs (0.87 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.3 Ω/Kft (4.3 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 19,100 lbs (85.0 KN) Nominal
Maximum Suggested Working Tension: 9,550 lbs (42.5 KN)

Number and Size of Wires:


Inner Armor 24 x 0.0390” (0.991 mm)
Outer Armor 24 x 0.0495” (1.257 mm)

Average Wire Breaking Strength:


Inner Armor 357 lbs (1.51 KN)
Outer Armor 575 lbs (2.56 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
7J46RP–HS 300 Poly 0.029 7x0.0128 9.8 40 0.096 Dacron 321 265
149 0.737 7x0.325 32.2 131 2.438 478 395
7J46RXZ–HS 420 Camtane 0.016 7x0.0128 9.8 40 0.070 Dacron 340 281
216 0.406 7x0.325 32.2 131 1.778 507 419
0.013 0.096
ETFE 0.330 2.438
7J46RTZ–HS 500 FEP 0.016 7x0.0128 9.8 39 0.070 Dacron 341 282
260 0.406 7x0.325 32.2 128 1.778 507 419
0.013 0.096
ETFE 0.330 2.438
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are postg tensioned.
∗ Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors. All values shown are nominal or typical values.
Rev: 02 23-July- 10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281) 342-4494 Fax: (281) 342-0531
29
3/8” (9.60mm)
7-CONDUCTOR

7Q38 – HS

PROPERTIES:
Cable Diameter: 0.378” +0.005” - 0.002” (9.60mm + 0.13mm -0.05mm)
Minimum Shave Diameter: 19” (48 cm)
Cable Stretch Coefficient 1.4 ft/Kft/Klbs (1.57 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1000 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.8 Ω/Kft (5.9 Ω/Km)

MECHANICAL:

Cable Breaking Strength:


Ends Fixed: 13,100 lbs (58.29 KN) Nominal
Ends Free:

Maximum Suggested Working Tension: 6,550 lbs (29.15 KN)

Number and Size of Wires:


Inner Armor 20 x 0.0358” (0.909 mm)
Outer Armor 20 x 0.047” (1.194 mm)

Average Wire Breaking Strength:


Inner Armor 286 lbs (1. 27 KN)
Outer Armor 494 lbs (2.19 KN)
Cable Type Core Description Cable Weight
Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm ΩKm pf/m mm Kg/Km
7QH38RP-HS 300 Poly 0.0160 7x0.0128 9.8 65 0.070 Dacron 236 195
149 0.4064 7x0.325 32.2 213 1.778 351 290
7QH38RZ-HS 500 ETFE 0.0160 7x0.0128 9.8 77 0.070 Dacron 243 201
260 0.4064 7x0.325 32.2 253 1.778 361 299
7QH38RA-HS 500 PFA 0.0160 7x0.0128 9.8 70 0.070 Dacron 247 204
260 0.4064 7x0.325 32.2 230 1.778 368 304

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 7×0.0128”. The typical capacitance is decreased by approximately 5 to 10% in
comparison to the outer conductors.
∗ All values shown are nominal or typical values.
REV. 1 23–July–10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 77471 Phone (281)342-4494 Fax (281) 342-0531
34
0.484” (12.29 mm)
7-CONDUCTOR
Extra
High Strength
7Q48

PROPERTIES:
Cable Diameter: 0.484” +0.006” - 0.003” (12.29mm + 0.15mm -0.076mm)
Minimum Shave Diameter: 27” (69 cm)
Cable Stretch Coefficient (Nominal): 0.61 ft/Kft/Klbs (0.69 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1000 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.00 Ω/Kft (3.3 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 27,100 lbs (120.6 KN) Nominal

Maximum Suggested Working Tension: 13,550 lbs (60.3 KN)

Number and Size of Wires:


Inner Armor 16 x 0.0535” (1.36 mm)
Outer Armor 18 x 0.0670” (1.70 mm)

Average Wire Breaking Strength:


Inner Armor 703 lbs (3.1 KN)
Outer Armor 1103 lbs (4.9 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F In in Ω/kft pf/ft In lbs/kft
°C Mm mm Ω/km pf/m Mm kg/km
500 FEP 0.0115 7x0.0128 9.8 46 0.061 Dacron 412 340
260 0.292 7x0.325 32.2 151 1.549 613 506
7Q48RTZ–EHS ETFE 0.0105 0.082
0.267 2.083
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Manufacturer recommends to maintain tension profile at all times, or conductor crushing can occur, and conductor
failure is not always immediate. If the tension profile is changed, it should be corrected immediately.
∗ Core assembly – Conductors are stranded and covered with ETFE plastic jacket. Conductors are “Water Blocked”
to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors.
• All values shown are nominal or typical values.
Rev: 02 23-July-10

CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone (281)342-4494 Fax: (281) 342–0531
36
0.490” (12.45mm)
7-CONDUCTOR
Extra-Extra
High Strength
7Q49 – EEHS

PROPERTIES:
Cable Diameter: 0.490” +0.006” - 0.002” (12.45mm + 0.15mm -0.051mm)
Minimum Shave Diameter: 25” (64 cm)
Cable Stretch Coefficient (Nominal): 0.60 ft/Kft/Klbs (0.67 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.00 Ω/Kft (3.3 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 29,500 lbs (131.3 KN) Nominal

Maximum Suggested Working Tension: 14,750 lbs (65.6 KN)

Number and Size of Wires:


Inner Armor 20 x 0.0460” (1.17 mm)
Outer Armor 20 x 0.0620” (1.57 mm)

Average Wire Breaking Strength:


Inner Armor 607 lbs (2.7 KN)
Outer Armor 1103 lbs (4.9 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Core in in
Rating Type Thickness Construction Typical Typical Each Jacketed Air H2O
Type
°F In in Ω/kft pf/ft In lbs/kft
°C Mm mm Ω/km pf/m mm kg/km
7Q49RTZZ–EEHS 500 FEP 0.0130 7x0.0128 9.8 27 0.064 ETFE 409 338
260 0.330 7x0.325 32.2 85 1.626 609 503
ETFE 0.0100 0.084
0.254 2.134
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Core assembly – Conductors are stranded and covered with ETFE plastic jacket. Conductors are “Water Blocked” to
reduce water and gas migration.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors.
∗ All values shown are nominal or typical values.
Rev: 01 April–10

CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg. Texas 77471 Phone (281)342–4494 Fax (281) 342–0531
35
0.490” (12.45mm)
7-CONDUCTOR
Extra
High Strength
7Q49 – EHS

PROPERTIES:
Cable Diameter: 0.490” +0.006” - 0.002” (12.45mm + 0.15mm -0.051mm)
Minimum Shave Diameter: 25” (64 cm)
Cable Stretch Coefficient (Nominal): 0.60 ft/Kft/Klbs (0.67 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 1.00 Ω/Kft (3.3 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 25,750 lbs (114.6 KN) Nominal

Maximum Suggested Working Tension: 12875 lbs (57.3 KN)

Number and Size of Wires:


Inner Armor 20 x 0.0460” (1.17 mm)
Outer Armor 20 x 0.0620” (1.57 mm)

Average Wire Breaking Strength:


Inner Armor 532 lbs (2.4 KN)
Outer Armor 966 lbs (4.3 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Core in in
Rating Type Thickness Construction Typical Typical Each Jacketed Air H2O
Type
°F In In Ω/kft pf/ft In lbs/kft
°C Mm mm Ω/km pf/m mm kg/km
7Q49RTZZ–EHS 500 FEP 0.0130 7x0.0128 9.8 27 0.064 ETFE 409 338
260 0.330 7x0.325 32.2 89 1.626 609 503
ETFE 0.0100 0.084
0.254 2.134
∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Core assembly – Conductors are stranded and covered with ETFE plastic jacket. Conductors are “Water Blocked” to
reduce water and gas migration.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors.
∗ All values shown are nominal or typical values.
Rev: 02 23-July–10

CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg. Texas 77471 Phone (281)342–4494 Fax (281) 342–0531
37

0.521” (13.23mm)
7-CONDUCTOR

7Q52

PROPERTIES:
Cable Diameter: 0.521” +0.007” - 0.003” (13.23mm + 0.18mm -0.076mm)
Minimum Shave Diameter: 26” (67 cm)
Cable Stretch Coefficient (Nominal): 0.58 ft/Kft/Klbs (0.65 m/km/5KN)

ELECTRICAL:
Maximum Conductor Voltage 1200 VDC
Conductor AWG Rating 20
Minimum Insulation Resistance 1,500 MegΩ/Kft @ 500VDC (457 MegΩ/Km @ 500VDC)
Armor Electrical Resistance: 0.85 Ω/Kft (2.8 Ω/Km)

MECHANICAL:
Cable Breaking Strength:
Ends Fixed: 25,500 lbs (113.5 KN) Nominal

Maximum Suggested Working Tension: 12,750 lbs (56.7 KN)

Number and Size of Wires:


Inner Armor 16 x 0.0585” (1.490 mm)
Outer Armor 20 x 0.0655” (1.664 mm)

Average Wire Breaking Strength:


Inner Armor 726 lbs (3.23 KN)
Outer Armor 910 lbs (4.05 KN)

Cable Type Core Description Cable Weight


Temp Plastic Insulation Copper Res. Cap. O.D. Tape in in
Rating Type Thickness Construction Typical Typical Each Type Air H2O
°F in in Ω/Kft pf/ft in lbs/Kft
°C mm mm Ω/Km pf/m mm Kg/Km
7Q52RP 300 Poly 0.027 7x0.0128 9.8 42 0.092 Dacron 449 371
149 0.686 7x0.325 32.2 139 2.340 669 553
7Q52RXZ 420 Camtane 0.016 7x0.0128 9.8 43 0.070 Dacron 455 379
216 0.406 7x0.325 32.2 141 1.778 677 560
0.011 0.092
ETFE 0.279 2.340
7Q52RTZ 500 ETFE 0.016 7x0.0128 9.8 40 0.070 Dacron 468 387
260 0.406 7x0.325 32.2 131 1.778 696 55
0.011 0.092
FEP 0.279 2.340

∗ The armor wires are high tensile, Galvanized Extra Improved Plow Steel (GEIPS), and coated with anti-corrosion
compound for protection during shipping and storing. Wires are preformed and cables are post tensioned.
∗ Core assembly – Conductors are bound with conductive tape and voids are filled with conductive paste and string.
∗ Conductors are “Water Blocked” to reduce water and gas migration. Conductor resistance is measured at 68 deg. F.
∗ The temperature rating assumes a normal gradient for both temperature and weight.
∗ Center conductor construction is 6×0.0142” with a non-conductive center member. The typical resistance is reduced
by approximately 5 to 10% and the capacitance is increased by approximately 5 to 10% in comparison to the outer
conductors.
∗ All values shown are nominal or typical values.
Rev: 02 23-July– 10

CAMESA INC.1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone (281) 342–4494 Fax: (281) 342–0531
38

DYCAM

Type (Nominal diameter) 3/16" 7/32" 1/4"


CONSTRUCTION 1x19 (1-9-9) 1x19 (1-9-9) 1X19(1-9-9)
Inner Layer – Right
Center Wire Diameter .056”(1.42 mm) .066"(1.68 mm) .076"(1.93 mm)
Number of Outer Wires 9 9 9
Outer Wire Diameter .027"(0.69 mm) .032"(0.81 mm) .038"(0.97 mm)
Outer Layer – Right
Outside Diameter .188"(4.78 mm) .219"(5.56 mm) .250"(6.35 mm)
Number Wires 9 9 9
Wire Diameter .049"(1.24 mm) .056"(1.42 mm) .066"(1.68 mm)
MECHANICAL CHARACTERISTICS
Breaking Strength 6.4 Klbs (2.9 metric tons) 8.6Klbs (3.9 metric tons) 11.0 Klb (5.0 metric tons)
Weight 87.7 lb/Kft 116.5 lb/Kft 162 lbs/Kft.
(130.56 kg/km) (173.4 kg/km) (241.7 kg/km)
Diameter Tolerance +2% - 0% +2% - 0% +2% - 0%
Calculated Stretch Coefficient 2.17 ft/Kft/Klb 1.28 ft/Kft/Klb 0.87 ft/Kft/Klb

Type (Nominal diameter) 5/16”


CONSTRUCTION 1x19 (1-9-9)
Inner Layer – Right
Center wire diameter .096” (2.43 mm)
Number of outer wires 9
Outer wire diameter .045"(1.14mm)
Outer Layer - Right
Outside diameter .313"(7.9 mm)
Number wires 9
Wire diameter .080"(2.03 mm)
MECHANICAL CHARACTERISTICS
Breaking Strength 15.9 Klbs (7.2 metric tons)
Weight 275.8 lb/Kft
(410.4 kg/km)
Diameter Tolerance +2% - 0%
Calculated Stretch Coefficient 0.80 ft/Kft/Klb
∗ Recommended maximum working load at 50 % of total cable breaking strength.
Rev: 02 23–July–10

CAMESA, INC. 1615 Spur 529 P.O. Box 1048 Rosenberg, Texas 77471 Phone: (281) 342 – 4494 Fax (281) 342 - 0531
Swab and dycam min sheave

Min.
sheave Ø

SWABLINE 3/16 1X16 13.8”

SWABLINE 7/32 1X16 16.9”

SWABLINE 1/4 1X19S 15.0”

SWABLINE 5/16 1X19S 19.4”

DYCAM 3/16 1X19S 15.3”

DYCAM 7/32 1X19S 17.5”

DYCAM 1/4 1X19S 20.6”

DYCAM 5/16 1X19S 25.0”


SWABLINE 3/16 MBS, MBS,
1X16 # wires lbf DYCAM 3/16 1X19S # wires lbf
555204400010 9 (outer) 389.3 575304900012 9 509.6
555203200010 6 (inner) 205.9 555202700016 9 162.9
555203600010 1 central 118 555205600016 1 700.6

SWABLINE 7/32 TORON DYC 7/32


1X16 1X19S
555205400010 9 586.3 575305600012 9 665.3
555203800010 6 290.3 555203200016 9 228.8
555204200010 1 354.7 555206600016 1 973.2

SWABLINE 1/4 TORON DYC 1/4


1X19 1X19S
555204800010 12 463.3 575306600012 9 924.5
555204800010 6 463.3 555203800016 9 322.6
555205800010 1 676.4 555207600016 1 1290.4

SWABLINE 5/16 TORON DYC 5/16


1X19 1X19S
555206200010 12 772.9 575308000012 9 1358.3
555206200010 6 772.9 555204200016 9 394.1
555207200010 1 1042.3 555208600016 1 1539.1

P. O. Box 1048, 1615 Spur 529, Rosenberg, TX 77471 Tel. 281-342-4494 Fax. 281-342-0531
Email: rleblanc@wirecoworldgroup.com
39

SWAB LINES

Type (Nominal diameter) 3/16” 7/32” 1/4”


CONSTRUCTION (Special) 1 x 16 (1-6-9) 1 x 16 (1-6-9) 1 x 19 (1-6-12)
Inner Layer – Left
Outside Diameter 0.100” (2.54 mm) 0.118” (3.0 mm) 0.154” (3.91 mm)
Center Wire Diameter 0.036” (0.91 mm) 0.042” (1.1 mm) 0.058” (1.47 mm)
Number of Outer Wires 6 6 6
Outer Wire Diameter 0.032” (0.81 mm) 0.038” (0.97 mm) 0.048” (1.22 mm)
Outer Layer – Right
Outside diameter 0.188” (4.78 mm) 0.219” (5.56 mm) 0.250” (6.35 mm)
Number Wires 9 9 12
Wire Diameter 0.044” (1.12 mm) 0.054” (1.37 mm) 0.048” (1.22 mm)
MECHANICAL CHARACTERISTICS
Breaking Strength 4.6 Klb 6.8 Klb 8.3 Klb
Maximum Suggested Tension 2.3 Klb 3.4 Klb 4.2 Klb
Weight (70.6 lb/Kft) (104.2 kg/Km) (127.1 lb/Kf)
Diameter Tolerance +-2%; -0% +-2%; -0% +-2%;
Calculated Stretch Coefficient 2.85 ft/Kft/Klb 1.80 ft/Kft/Klb 1.70 ft/Kft/Klb

Type (Nominal Diameter 5/16” 7/16”


CONSTRUCTION 1 x 19 (1-6-12) 1 x 19 (1-6-12)
Inner Layer – Left
Outside Diameter 0.196” (4.98 mm) 0.266” (6.76 mm)
Center Wire Diameter 0.072” (1.83 mm) 0.094” (2.39 mm)
Number of Outer Wires 6 6
Outer Wire Diameter 0.062” (1.57 mm) 0.086” (2.18 mm)
Outer Layer – Right
Outside diameter 0.313” (7.94 mm) 0.438” (11.11 mm)
Number Wires 12 12
Wire Diameter 0.062” (1.57 mm) 0.086” (2.18 mm)

MECHANICAL CHARACTERISTICS
Breaking Strength 13.9 Klb 21.6 Klb
Maximum Suggested Tension 6.9 Klb 10.8 Klb
Weight (207.6 lb/Kft) (394 lb/Kft)
Diameter Tolerance +--2%
Calculated Stretch Coefficient 1.10 ft/Kft/Klb +-2%

∗ The armor wires are Galvanized Improved Plow Steel (GIPS) with anticorrosion compound for protection during
shipping and storing.
∗ SUPERSEAL, a special pressure seal agent could be applied between armor layers.
∗ Recommended maximum working load at 50 % of total cable breaking strength.

Rev: 02 23–July– 10

CAMESA INC.1615 Spur 529 P.O.Box 1048 Rosenberg, Texas 777471 Phone (281) 342-4494 Facsimile (281) 342-0531