Download as pdf or txt
Download as pdf or txt
You are on page 1of 48

Technical Data for ADL Power Supplies

Seite
GS 05 - GS 30 2
GS 60 - GS 150 4
GSW 100 - GSW 300 5
GX 50 - GX 150 9
HX 150 - HX 300 11
GP and GPW-Power Supplies for Melec Pulse Generators 13
ADL-Pulse Generator RD 300 16
Power Supplies for Ion Sources - Accelerator and Beam GG 03, GG03.1, GG12, GG 12.1 17
Power Supplies for Ion Sources - Neutralizer GIP 10 and GIP 10.1 18
Power Supplies for Ion Sources - Discharge GDI 19
Power Supplies for Ion Sources - Cathode GC 20
Power Supplies for Ion Sources - Magnet GM 21
Power Supplies for Plasma Sources - GD 22
D300 Cathode Clamp Diode 23
Maris Remote Control RC 4 24

ADL

ADL Technical Data Version 09-2009 1


GS 05 - GS 30
GS GS GS GS GS
Table 1
05/800 10/800 15/800 20/800 30/800
Nominal power 0,5kW 1kW 1,5kW 2kW 3kW

Output voltage 800V 800V 800V 800V 800V

Output current 0,9A 1,7A 3A 3,5A 5,3A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power

Noise emission LpA < 70db (A)


230V, +5/-10 %, 50/60Hz, 3 x 400V, +5/-10%, 50/60Hz,
Mains connection
(Option: 200V, L1, L2, PE) (Option: 3 x 200V, only GS 15, GS 20), PE
Power consumption 0,6kVA 1,2kVA 1,8kVA 2,4kVA 3,6kVA

Fusing 6A 6A 6A (10A) 6A (10A) 10A

Cooling Forced air, maximum ambiente temperature 40° C

Size ½ 19“ slide-in, 3HU (132,5mm), 560mm deep

Weight 11kg 12kg

ADL Technical Data Version 09-2009 2


GS GS GS GS GS GS
Table 2
05/1000 10/1000 15/1000 20/1000 30/1000 12/2000
Nominal power 0,5kW 1kW 1,5kW 2kW 3kW 1,2kW

Output voltage 1000V 1000V 1000V 1000V 1000V 2000V

Output current 0,7A 1,4A 2,4A 2,8A 4,2A 1A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay Time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power

Noise emission LpA < 70db (A)

230V, +5/-10%, 50/60Hz, 3 x 400V, +5/-10%, 50/60Hz,


Mains connection
(Option: 200V, L1, L2, PE) (Option: 3 x 200V, nur GS 15, GS 20), PE

Power consumption 0,6kVA 1,2kVA 1,8kVA 2,4kVA 3,6kVA 1,4kVA

Fusing 6A 6A 6A (10A) 6A (10A) 10A 6A

Cooling Forced air, maximum ambiente temperature 40° C

Size ½ 19“ slide-in, 3HU (132,5mm), 560mm deep

Weight 11kg 12kg

ADL Technical Data Version 09-2009 3


GS 60 - GS 150
GS GS GS GS GS
Table 1
60/800 80/800 100/800 120/800 150/800
Nominal power 6kW 8kW 10kW 12kW 15kW

Output voltage 800V 800V 800V 800V 800V

Output current 10A 17A 17A 20A 25A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)

Mains connection 3 x 400V, +5/-10%, 50/60Hz, PE

Power consumption 6,6kVA 9kVA 11kVA 13,2kVA 16,5kVA

Fusing 16A 16A 20A 25A 25A

Cooling Forced air, maximum ambiente temperature 40° C

Size 19“ slide-in, 3HU (132,5mm) 570mm deep

Weight 27kg 29kg 29kg 29kg 31kg

Mains cable 4 x 1,5mm² 4 x 1,5mm² 4 x 2,5mm² 4 x 4mm² 4 x 4mm²

RG 213U or
Output cable
3 x 1,5mm² 3 x 2,5mm² 3 x 2,5mm² 3 x 2,5mm² 3 x 4mm²

ADL Technical Data Version 09-2009 4


GSW 100 - GSW 300
GSW GSW GSW GSW GSW GSW
Table 1
100/500 100/800 150/400 150/500 150/600 150/750
Nominal power 10kW 10kW 15kW 15kW 15kW 15kW

Output voltage 500V 800V 400V 500V 600V 750V

Output current 40A 20A 80A 60A 50A 38A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)


3 x 400V, +/-10%, 50/60Hz, PE
Mains connection
(Option: 3 x 440V oder 3 x 480V)
Power consumption 11kVA 11kVA 16,5kVA 16,5kVA 16,5kVA 16,5kVA

Fusing 3 x 20A 3 x 20A 3 x 25A 3 x 25A 3 x 25A 3 x 25A


Water, > 3 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
Water connection Swagelok B-QC 6 …

Cooling capability of water 500W 500W 680W 680W 680W 680W

Cooling capability of air 80W 80W 80W 80W 80W 80W

Size 19“ slide-in, 3HU x 700mm deep (without plug)

Weight 42kg 42kg 44kg 44kg 44kg 44kg

Mains cable 4 x 2,5mm² 4 x 2,5mm² 4 x 4mm² 4 x 4mm² 4 x 4mm² 4 x 4mm²

Output cable 3 x 10mm² 3 x 2,5mm² 3 x 25mm² 3 x 16mm² 3 x 10mm² 3 x 10mm²

Mains connection (X2) Harting Han k4/0

DC-connection (X1) Harting Han 2 MOD

ADL Technical Data Version 09-2009 5


GSW GSW GSW GSW GSW GSW
Table 2
150/800 150/1000 200/500 200/750 200/800 200/900
Nominal power 15kW 15kW 20kW 20kW 20kW 20kW

Output voltage 800V 1000V 500V 750V 800V 900V

Output current 30A 25A 70A 50A 40A 40A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)


3 x 400V, +/-10%, 50/60Hz, PE
Mains connection
(Option: 3 x 440V oder 3 x 480V)
Power consumption 16,5kVA 16,5kVA 22kVA 22kVA 22kVA 22kVA

Fusing 3 x 25A 3 x 25A 3 x 35A 3 x 35A 3 x 35A 3 x 35A


Water, > 3 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
Water connection Swagelok B-QC 6 …

Cooling capability of water 680W 680W 950W 900W 900W 900W

Cooling capability of air 80W 80W 150W 100W 100W 100W

Size 19“ slide-in, 3HU x 700mm deep (without plug)

Weight 44kg 44kg 49kg 49kg 49kg 49kg

Mains cable 4 x 4mm² 4 x 4mm² 4 x 6mm² 4 x 6mm² 4 x 6mm² 4 x 6mm²

Output cable 3 x 6mm² 3 x 4mm² 3 x 16mm² 3 x 10mm² 3 x 10mm² 3 x 10mm²

Mains connection (X2) Harting Han k4/0

DC-connection (X1) Harting Han 2 MOD

ADL Technical Data Version 09-2009 6


GSW GSW GSW GSW GSW GSW
Table 3
200/1000 250/750 250/800 250/900 300/500 300/800
Nominal power 20kW 25kW 25kW 25kW 30kW 30kW

Output voltage 1000V 750V 800V 900V 500V 800V

Output current 35A 60A 50A 50A 70A 60A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)


3 x 400V, +/-10%, 50/60Hz, PE
Mains connection
(Option: 3 x 440V oder 3 x 480V)
Power consumption 22kVA 28kVA 28kVA 28kVA 33kVA 33kVA

Fusing 3 x 35A 3 x 50A 3 x 50A 3 x 50A 3 x 63A 3 x 63A


Water, > 3 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
Water connection Swagelok B-QC 6 …

Cooling capability of water 900W 1100W 1100W 1100W 1300W 1300W

Cooling capability of air 100W 110W 110W 110W 150W 150W

Size 19“ slide-in, 3HU x 700mm deep (without plug)

Weight 49kg 51kg 51kg 51kg 53kg 53kg

Mains cable 4 x 6mm² 4 x 10mm² 4 x 10mm² 4 x 10mm² 4 x 10mm² 4 x 10mm²

Output cable 3 x 6mm² 3 x 16mm² 3 x 10mm² 3 x 10mm² 3 x 16mm² 3 x 16mm²

Mains connection (X2) Harting Han k4/0

DC-connection (X1) Harting Han 2 MOD

ADL Technical Data Version 09-2009 7


GSW
Table 4
300/1000
Nominal power 30kW

Output voltage 1000V

Output current 50A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)


3 x 400V, +/-10%, 50/60Hz, PE
Mains connection
(Option: 3 x 440V oder 3 x 480V)
Power consumption 33kVA

Fusing 3 x 63A
Water, > 3 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
Water connection Swagelok B-QC 6 …

Cooling capability of water 1300W

Cooling capability of air 150W

Size 19“ slide-in, 3HU x 700mm deep (without plug)

Weight 53kg

Mains cable 4 x 10mm²

Output cable 3 x 10mm²

Mains connection (X2) Harting Han k4/0

DC-connection (X1) Harting Han 2 MOD

ADL Technical Data Version 09-2009 8


GX 60 - GX 150
GX GX GX GX GX GX
Table 1
50/800 60/800 80/800 80/1000 100/400 100/600
Nominal power 5kW 6kW 8kW 8kW 10kW 10kW

Output voltage 800V 800V 800V 1000V 400V 600V

Output current 14A 15A 20A 16A 38A 30A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)


3 x 400V, +/-10%, 50/60Hz
Mains connection

Power consumption 6kVA 6,6kVA 9kVA 9kVA 11kVA 11kVA

Fusing 3 x 16A 3 x 16A 3 x 20A 3 x 20A 3 x 20A 3 x 20A


Water, > 1,5 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
Water connection Swagelok B-QC 6 …

Cooling capability of water 300W 300W 400W 400W 500W 500W

Cooling capability of air 45W 45W 50W 50W 50W 50W


½ 19“ slide-in, 3HU (130mm) 520mm deep (without plug),
Size
590mm (with plug).
Weight 21kg 21kg 23kg 23kg 23kg 23kg

Mains cable 4 x 1,5mm² 4 x 1,5mm² 4 x 2,5mm² 4 x 2,5mm² 4 x 2,5mm² 4 x 2,5mm²

Output cable 3 x 1,5mm² 3 x 1,5mm² 3 x 2,5mm² 3 x 2,5mm² 3 x 6mm² 3 x 6mm²

Mains connection (X2) Harting Han-Modular Compact

DC-connection (X1) Harting Han-Modular Compact

ADL Technical Data Version 09-2009 9


GX GX GX GX GX
Table 2
100/800 100/1000 120/800 150/800 150/1000
Nominal power 10kW 10kW 12kW 15kW 15kW

Output voltage 800V 1000V 800V 800V 1000V

Output current 25A 20A 30A 38A 30A

Control Current, voltage or power controlled


Manual via front panel or external via A/D interface AS 4,
Modes of operation
AS 4 F or Profibus
Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)

Mains connection 3 x 400V, +/-10%, 50/60Hz

Power consumption 11kVA 11kVA 13,2kVA 16,5kVA 16,5kVA

Fusing 3 x 20A 3 x 20A 3,25A 3 x 25A 3 x 25A


Water, > 1,5 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
Water connection Swagelok B-QC 6 …

Cooling capability of water 500W 500W 600W 750W 750W

Cooling capability of air 50W 50W 60W 60W 60W


½ 19“ slide-in, 3HU (130mm) 520mm deep (without plug),
Size
590mm (with plug).
Weight 23kg 23kg 23kg 25kg 25kg

Mains cable 4 x 2,5mm² 4 x 2,5mm² 4 x 4mm² 4 x 4mm² 4 x 4mm²

Output cable 3 x 4mm² 3 x 4mm² 3 x 6mm² 3 x 6mm² 3 x 6mm²

Mains connection (X2) Harting Han-Modular Compact

DC-connection (X1) Harting Han-Modular Compact

ADL Technical Data Version 09-2009 10


HX 150 - HX 300
HX HX HX HX HX HX
Table 1
150/400 150/500 150/600 150/800 150/1000 200/500
Nominal power 15kW 15kW 15kW 15kW 15kW 20kW

Output voltage 400V 500V 600V 800V 1000V 500V

Output current 80A 60A 50A 30A 25A 70A

Control Current, voltage or power controlled

Modes of operation External via A/D interface AS 4, AS 4 F or Profibus

Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)


3 x 400V, +/-10 %, 50/60Hz
Mains connection
(Option: 3 x 440V or 3 x 480V)

Power consumption 16,5kVA 16,5kVA 16,5kVA 16,5kVA 16,5kVA 22kVA

Fusing 3 x 25A 3 x 25A 3 x 25A 3 x 25A 3 x 25A 3 x 35A


Water, > 3 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
SMC KQ2 10mm
Water connection
(Option: Swagelok B QC-6)

Cooling capability of water 680W 680W 680W 680W 680W 950W

Cooling capability of air 80W 80W 80W 80W 80W 150W

Size Width: 218mm, Hight: 222mm, Length (without plug): 645mm

Weight 35kg 35kg 35kg 32kg 32kg 37kg

Mains cable 4 x 4mm² 4 x 4mm² 4 x 4mm² 4 x 4 mm² 4 x 4mm² 4 x 6mm²

Output cable 3 x 25mm² 3 x 16mm² 3 x 10mm² 3 x 6mm² 3 x 4mm² 3 x 16mm²

Mains connection (X2) Harting Han k4/0

DC-connection (X1) Harting Han 2 MOD

ADL Technical Data Version 09-2009 11


HX HX HX HX HX HX
Table 2
200/800 200/1000 250/800 250/1000 300/800 300/1000
Nominal power 20kW 20kW 25kW 25kW 30kW 30kW

Output voltage 800V 1000V 800V 1000V 800V 1000V

Output current 40A 35A 50A 40A 60A 50A

Control Current, voltage or power controlled

Modes of operation External via A/D interface AS 4, AS 4 F or Profibus

Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power (Option)

Noise emission LpA < 70db (A)


3 x 400V, +/-10 %, 50/60Hz
Mains connection
(Option: 3 x 440V or 3 x 480V)

Power consumption 22kVA 22kVA 28kVA 28kVA 33kVA 33kVA

Fusing 3 x 35A 3 x 35A 3 x 50A 3 x 50A 3 x 63A 3 x 63A


Water, > 3 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
SMC KQ2 10mm
Water connection
(Option: Swagelok B QC-6)

Cooling capability of water 900W 900W 1100W 1100W 1300W 1300W

Cooling capability of air 100W 100W 110W 110W 150W 150W

Size Width: 218mm, Hight: 222mm, Length (without plug): 645mm

Weight 37kg 37kg 39kg 39kg 41kg 41kg

Mains cable 4 x 6mm² 4 x 6mm² 4 x 10mm² 4 x 10mm² 4 x 10mm² 4 x 10mm²

Output cable 3 x 10mm² 3 x 6mm² 3 x 10mm² 3 x 10mm² 3 x 16mm² 3 x 10mm²

Mains connection (X2) Harting Han k4/0

DC-connection (X1) Harting Han 2 MOD

ADL Technical Data Version 09-2009 12


Power Supplies for Melec-Pulse Generator
GP GP GP GP GP
Table 1
10/800 15/800 20/800 30/800 30/1000
Nominal power 1kW 1,5kW 2kW 3kW 3kW

Output voltage 800V 800V 800V 800V 1000V

Output current 1,7A 3A 3,5A 5,3A 4,2A

Control Current, voltage or power controlled

Modes of operation External via A/D interface AS 6

Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Indications 3½- digit display for current, voltage and power

Noise emission LpA < 70db (A)

230V,
+5/-10%,
50/60Hz, 3 x 400V, +5/-10%, 50/60Hz,
Mains connection
(Option: (Option: 3 x 200V, nur GP 15, GP 20), PE
200V, L1, L2,
PE)

Power consumption 1,2kVA 1,8kVA 2,4kVA 3,6kVA 3,6kVA

Fusing 6A 6A (10A) 6A (10A) 10A 10A

Cooling Forced air, maximum ambiente temperature 40° C

Seize ½ 19“ slide-in, 3HU (132,5mm), 560mm deep

Weight 11kg 12kg

ADL Technical Data Version 09-2009 13


GP GP GP GP
Table 2
60/800 100/800 120/800 150/800
Nominal power 6kW 10kW 12kW 15kW

Output current 800V 800V 800V 800V

Output voltage 10A 17A 20A 25A

Control Current, voltage or power controlled

Modes of operation External via A/D interface AS 6

Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Noise emission 3½- digit display for current, voltage and power

Mains connection 3 x 400V, +/-10%, 50/60Hz, PE

Power consumption 6,6kVA 11kVA 13,2kVA 16,5kVA

Fusing 16A 20A 25A 25A

Cooling Forced air, maximum ambiente temperature 40° C

Seize ½ 19“ slide-in, 3HU (132,5mm), 560mm deep

Weight 27kg 29kg 29kg 31kg

Mains cable 4 x 1,5mm² 4 x 2,5mm² 4 x 4mm² 4 x 4mm²

RG 213U or
Output cable
3 x 1,5mm² 3 x 2,5mm² 3 x 2,5mm² 3 x 4mm²

ADL Technical Data Version 09-2009 14


GPW GPW GPW GPW GPW
Table 3
150/800 200/800 250/800 300/800 300/1000
Nominal power 15kW 20kW 25kW 30kW 30kW

Output voltage 800V 800V 800V 800V 1000V

Output current 30A 40A 50A 60A 50A

Control Current, voltage or power controlled

Modes of operation External via A/D interface AS 6

Set point 0 …100 % of nominal current, voltage or power

Output accuracy +/- 1 % of nominal value for current, voltage or power


Quenching time: 6µs up to 3ms, automatically
Arc suppression
Delay time: 6µs up ca. 10ms, automatically
Noise emission 3½- digit display for current, voltage and power

Mains connection 3 x 400V, +/-10%, 50/60Hz

Power consumption 16,5kVA 22kVA 28kVA 33kVA 33kVA

Fusing 3 x 25A 3 x 35A 3 x 50A 3 x 63A 3 x 63A


Water, > 3 L/Min, 2 to 8 Bar, < 40° C
Cooling
Forced air, maximum ambiente temperature 40° C
Water connection Swagelok B-QC 6 …

Cooling capability of water 680W 900W 1100W 1300W 1300W

Cooling capability of air 80W 100W 110W 150W 150W

Seize 19“ slide-in, 3HU x 700mm deep (without plug)

Weight 44kg 49kg 51kg 53kg 53kg

Mains cable 4 x 4mm² 4 x 6mm² 4 x 10mm² 4 x 10mm² 4 x 10mm²

Output cable 3 x 6mm² 3 x 10mm² 3 x 10mm² 3 x 16mm² 3 x 10mm²

Mains connection (X2) Harting Han k4/0

DC-Connection (X1) Harting Han 2 MOD

ADL Technical Data Version 09-2009 15


ADL-Pulse Generator RD 300
Table 1 RD 300

Nominal voltage 800V (DC Output voltage of power supply)

Nominal power 30kW (DC Output power of power supply)

Pulse frequency 2kHz, fixed

Pulse on time 480µS bis 490µS

Pulse off time 10µS bis 20µS

Principle of operation ZVS (Zero Voltage Switch) Resonance converter

Maximum cable length 5m (between Pulse Generator and Cathode)

Indications Status LEDs

Auxiliary voltage 24V DC +/- 10%, 0,6A

Cooling Forced air, maximum ambiente temperature 40° C

Seize 157mm width, 118mm height, 430mm length

Weight 8 kg

Compatible with the Power supplies of the series GS and GSW with a
following power supplies: maximum nominal power of 30kW

ADL Technical Data Version 09-2009 16


Accelerator and Beam GG 03, GG 03.1, GG 12, GG 12.1
Table 1 GG 03 GG 03.1 GG 12 GG 12.1

Nominal power 300W 30W 1,2kW 200W


Negative, Negative, Positive, max. Positive, max.
Output voltage
max. 1000V max. 1000V 2000V 2000V
Output current 300mA 30mA 1A 100mA

Control Voltage or current controlled

Modes of operation Manual via frontpanel or external via A/D Interface AS 4 or Profibus

Set point 0 ...100 % of nominal voltage or current

Indications 3 ½ digit displays for voltage and current

Noise emission LpA < 70 db(A)

230V, +5/-10%, 50/60Hz, PE


Mains connections
500VA 100VA 1500VA 250VA

Cooling Forced air, maximum ambiente temperature 40° C

Seize ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)

Weight 11kg

ADL Technical Data Version 09-2009 17


Neutralizer GIP 10 and GIP 10.1
GIP 10 GIP 10.1
Table 1
Cathode Discharge Emission Cathode Emission
Nominal power 990W 25W 25W 990W 2,5W

Output voltage 33V 25V 25V 33V 25V

Output current 30A 1A 1A 30A 0,1A

Control Emission or filament current controlled

Modes of operation Manual via frontpanel or external via A/D Interface AS 4 or Profibus

Set point 0 ...100 % of nominal emission or filament current

Indications 3 ½ digit displays for emission and filament current

Noise emission LpA < 70db(A)

Mains connection 230V, +5/-10%, 50/60Hz, PE , 1200VA

Cooling Forced air, maximum ambiente temperature 40° C

Seize ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)

Weight 11kg

ADL Technical Data Version 09-2009 18


Discharge GDI
Table 1 GDI 09

Nominal power 900W

Output voltage 150V, floating up to 2kV

Output current 6A

Control Voltage or current controlled.

Modes of operation Manual via frontpanel or external via A/D Interface AS 4 or Profibus

Set point 0 ...100 % of nominal voltage or current

Indications 3 ½ digit displays for voltage and current

Noise emission LpA < 70db(A)

Mains connection 230V, +5/-10%, 50/60Hz, PE, 1200VA

Cooling Forced air, maximum ambiente temperature 40° C

Seize ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)

Weight 11kg

ADL Technical Data Version 09-2009 19


Cathode
Table 1 GC 10

Nominal power 1kW

Output voltage 35V, floating up to 2kV

Output current 30A

Control Voltage or current controlled

Modes of operation Manual via frontpanel or external via A/D Interface AS 4 or Profibus

Set point 0 ...100 % of nominal voltage or current

Indications 3 ½ digit displays for voltage and current

Noise emission LpA < 70db(A)

Mains connection 230V, +5/-10%, 50/60Hz, PE, 1200VA

Cooling Forced air, maximum ambiente temperature 40° C

Seize ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)

Weight 11kg

ADL Technical Data Version 09-2009 20


Magnet GM 10
Table 1 GM 10

Nominal power 960W

Output voltage 160V, floating

Output current 6A

Control Voltage or current controlled

Modes of operation Manual via frontpanel or external via A/D Interface AS 4 or Profibus

Set point 0 ...100 % of nominal voltage or current

Indications 3 ½ digit displays for voltage and current

Noise emission LpA < 70db(A)

Mains connection 230V, +5/-10%, 50/60Hz, PE, 1200VA

Cooling Forced air, maximum ambiente temperature 40° C

Seize ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)

Weight 11kg

ADL Technical Data Version 09-2009 21


Plasma Sources
GD GD GD GD GD GD
Table 1
20/400 20/600 20/800 30/400 30/600 30/800
Nominal power 2kW 2kW 2kW 3kW 3kW 3kW

Output voltage 400V 600V 800V 400V 600V 800V

Output current 7A 4,5A 3,5A 10A 6,5A 5,3A

Control Voltage or current controlled

Modes of operation Manual via front panel or external via A/D interface AS 4 or Profibus

Set point 0 ...100 % of nominal voltage or current

Indications 3 ½ digit displays for voltage and current

Noise emission LpA < 70 db(A)


3 x 400V, +5/-10%, 50/60Hz, PE
Mains connection
(Option: 3 x 200V, only GD 20)
Cooling Forced air, maximum ambiente temperature 40° C

Seize ½ 19” slide-in, 3 HU (132,5 mm), 560 mm deep (incl. plug)

Weight 11kg

ADL Technical Data Version 09-2009 22


D300 Cathode Clamp Diode
HV-Diode, Table 1 D300

Nominal voltage 1000V DC Output voltage of power supply)

Nominal current 70A DC (Output cuurent of power supply)

Forward Voltage 3,5V

Connection Coaxial cable RG 213 U, PE

Maximum cable length 3m

Housing Aluminum B 125 mm x L 127 m x H 60 mm

Protection IP 56

Weight ca. 0,9 kg (without cable)

Compatible with the Power Supplies of the series GS, GSW and GX
following power supplies: with a maximum nominal voltage of 30kW

ADL Technical Data Version 09-2009 23


Remote Control
Table 1 RC 4

AS 3, AS 4, AS 4F (with Adapter)-cable
Interface compatibility
Control connection 25-pol. Sub.-D
24V DC, internal voltage suppy via interface
Operation voltage

3½-digit LCD, switchable to actual value power, actual value current and actual value
Indication
voltage, set point, reference voltage

Modes of operation Switchable: Operation via remote control or via front panel

Control Switchable: Current, power or voltage control

Set value setting Potentiometer with 10-turn-dial mechanism

Seize 280mm x 140mm x 110mm

Weight Ca. 0,7kg (without cable)

ADL Technical Data Version 09-2009 24


ADL Technical Data Version 09-2009 25
ADL Technical Data Version 09-2009 26
ADL Technical Data Version 09-2009 27
ADL Technical Data Version 09-2009 28
ADL Technical Data Version 09-2009 29
ADL Technical Data Version 09-2009 30
ADL Technical Data Version 09-2009 31
ADL Technical Data Version 09-2009 32
ADL Technical Data Version 09-2009 33
ADL Technical Data Version 09-2009 34
ADL Technical Data Version 09-2009 35
ADL Technical Data Version 09-2009 36
ADL Technical Data Version 09-2009 37
ADL Technical Data Version 09-2009 38
ADL Technical Data Version 09-2009 39
ADL Technical Data Version 09-2009 40
ADL Technical Data Version 09-2009 41
ADL Technical Data Version 09-2009 42
ADL Technical Data Version 09-2009 43
ADL Technical Data Version 09-2009 44
ADL Technical Data Version 09-2009 45
ADL Technical Data Version 09-2009 46
ADL Technical Data Version 09-2009 47
ADL Technical Data Version 09-2009 48

You might also like