S.

No Item
1 104
2 106
3 110
4 111
5 114
6 116
7 117
8 118
9 119
10 120
11 121
12 122
13 124
14 128
15 129
16 135
17 136
18 137
19 140
20 400
21 401
22 403
23 404
24 405
25 407
26 411
27 412
28 414
29 415
30 417
31 416
32 418
33 419
34 420
35 423
36 424
37 425
38 430
39 431
40 432
41 433
42 434
43 435
44 436
45 437
46 440
47 441
48 446
49 447
50 448
51 449
52 453
53 454
54 463
55 469
56 470
57 477
58 478
59 479
60 480
61 482
62 483
63 484
64 485
65 486
66 489
67 493
68 494
69 495
70 496
71 498
72 499
73 500
74 501
75 502
76 503
77 504
78 505
79 506
80 509
81 510
82 512
83 513
84 514
85 515
86 516
87 517
88 518
89 520
90 582
91 585
92 586
93 587
94 590
95 596
96 598
97 602
98 705
99 708
100 709
101 710
102 711
103 712
104 716
105 717
106 719
107 720
108 721
109 725
110 726
111 727
112 730
113 731
114 732
115 734
116 836
117 840
118 841
119 844
120 845
121 847
122 848
123 849
124 855
125 859
126 860
127 861
128 930
129 933
130 936
131 937
132 940
Description
Electrical Distribution System The contractor to pay all costs requiered for supplying and applying of the 800KVA , 13.8/0.4 KV
Main Distribution Board ( Incomer 1250AT/1250AF to be installed in the back room of transformer for main power supply to t
Same as above but 1000 mm X 1000 mm
Same as above Cu/XLPE/PVC+
(4C x300mm2 but 600 mm X 1C
600x mm
150 mm2 Cu/PVC (E))
(4C x150mm2 Cu/XLPE/PVC+ 1C x70 mm2 Cu/PVC (E))
(4C x 70mm2 Cu/XLPE/PVC+ 1C x 35 mm2 Cu/PVC (E))
(4Cx50mm2 CU/XLPE/PVC+1Cx25mm2 CU/PVC (E)
(4Cx35mm2 CU/XLPE/PVC+1Cx16mm2 CU/PVC (E)
4C x 25mm2 Cu/XLPE/PVC+ 1C x 16 mm2 Cu/PVC (E)
4C x 16mm2 Cu/XLPE/PVC+ 1C x 16 mm2 Cu/PVC (E)

4C x 10mm2 Cu/XLPE/PVC+ 1C x 10 mm2 Cu/PVC (E )


(2C x 10mm2 Cu/XLPE/PVC+ 1C x 10 mm2 Cu/PVC (E )
50 mm dia.
110 mm dia.
Lighting fixture , Type F10
Lighting fixture , Type F11
Lighting fixture , Type F12
Supply
LPP-G and install Wall mounted horn speakers 10/20/30 watt with strope type to be installed on fence weather proof ip 65.
Flush Mounted combined lighting and power branch distribution Panel Board, Main Breaker of 100AT/100AF, 3ph, 60Hz, IP42
PP-UPS-1
Flush
DB-AC1Mounted power branch distribution Panel Board, Main Breaker of 63AT/100AF, 3ph, 60Hz, IP42 ,to be installed in the ro
Flush
DB-AC2Mounted AC branch distribution Panel Board, Main Breaker of 200AT/250AF,Adjustable, 3ph, 60Hz, IP42 ,to be installed
Flush
DB-AC3Mounted AC branch distribution Panel Board, Main Breaker of 200AT/250AF,Adjustable, 3ph, 60Hz, IP42 ,to be installed
Flush Mounted AC branch distribution Panel Board, Main Breaker of 200AT/250AF,Adjustable, 3ph, 60Hz, IP42 ,to be installed
Uninterruptible Power Supply (UPS-1) 10KVA , 400/230V, 60 Hz, 30 min. coverage time, with lead acid battaries. Including IGPT
Supply and installation of indoor LED lighting unit, A1 type, ceiling mounted, as per drawings and specifications
Ditto, but A1E type equipped with 3hr emergency backup battery.
Ditto, but A2E type equipped with 3hr emergency backup battery.
Supply and installation of indoor LED lighting unit, A3 type, as per drawings and specifications
Supply and installation of indoor LED lighting unit, A4 type, as per drawings and specifications
Ditto, but A3E type equipped with 3hr emergency backup battery.
Supply and installation of indoor LED lighting unit, A5 type, as per drawings and specifications
Ditto, but A5E type equipped with 3hr emergency backup battery.
Supply and installation of indoor LED lighting unit,WX1 type, as per drawings and specifications
Supply and installation of outdoor LED lighting unit, F14 type, as per drawings and specifications
Supply and installation of outdoor LED lighting unit, F15 type, as per drawings and specifications
Supply ,installation and testing LED EX - exit light unit, 230V, 60Hz,IP 65 with emergency back-up battery kit for 3 hrs., durati
Supply , installation and testing of wall mounted single socket outlet, 13A, 230V as indicated in the specs and drawings.
Supply , installation and testing of wall mounted duplex socket outlet, 13A, 230V as indicated in the specs and drawings.
Supply , installation and testing of wall mounted single socket outlet, 13A, 230V, weather proof IP55, as indicated in the specs
Supply , installation and testing of wall mounted single socket outlet, 13A, 230V, IP66, weather proof for outdoor areas,as indi
Supply, installation and testing of wall mounted single socket outlet for hand dryer, 30A, 230V as indicated in the specs and dr
Supply, installation and testing of wall mounted single socket outlet for cooking room, 30A, 230V type R and wires are 10mm a
Supply, installation and testing of wall mounted Power outlet with (230 v ،32A، 2P) SW for electric water heater, as indicated
Supply , installation and testing of electrical SW (45A, 2P) , wall mounted AC units
Push button Switch for Bell System of 20A, 230V
Electric Bell Devices of 230V , 60 HZ AC power Supply , 15cm diameter , brand name and the price include the conduits , wires
Supply , installation and testing of electrical disconnect switch (30A,230V, 2P, IP 65) ,for outdoor AC units,S.Fans.
Supply , installation and testing of Non-fusible disconnect switch , (60A, 4P,400V, IP 65) for FAHU units.
Supply , installation and testing of Non-fusible disconnect switch , (100A, 4P,400V, IP 65) for PACU units.
Switch Bank:
Supply, installation, testing and commissioning of control panel for AC system. It will be installed in administration rooms (Swi
four core cable , 4C 16 mm2 CU/XLPE/PVC + earthing cable , 1C *16 mm2 Cu/PVC .
four core cable , 4C 25 mm2 CU/XLPE/PVC + earthing cable , 1C *16 mm2 Cu/PVC .
Supply, install and test the complete grounding system network comprising of bare copper conductor or PVC insulated coppe
wall mounted Telephone Outlet including conduits and CAT 6A cables , RJ 45 type , as per specs , standard , code and engineer
Supplying, installing, connecting ,testing and commissioning of 5 external / 50 internal lines and able to be extended up to 10
Main computer patch panel including F.O. switch patch panel suitable for F.O
Supplying, installing, ,testing and running of branch information distributer ( 24 port edge switch ), (2sfb) type, 10/100/1000.
Supplying, installing, ,testing and running of main information distributer ( core switch ) capable for running all points with red
UTP CAT 6A, modular patch panel for 24 ports standard 19" width, RJ-45 type, including with termination,
Wall mounted single data outlet , RJ 45 with cat6A cable and all necessary for proper operation as per code and manufacturer
Branch Data terminal cabinet , 26U size , for computer branch data system , to be installed in floors for branch distributer
Main Data terminal cabinet , 42U size , for data system , to be installed in first floor , containing all main core switches ,
Supply, install, testing & commissioning of USB+HDMI Port Wall mounted next teacher table coupled to another USB+HDMI P
Wirless internet point
Floor box , hot dip galvanized steel box (FB-2), include 2 duplex sockets outlets, 2 data outlet,for computer lab.,including con
Amplifier 150 watt
Amplifier 120 watt
6/3/1 watt ,Ceiling mounted speaker
15/10/5 watt , wall mounted speaker
Microphone outlet
AM/FM Radio tuner
Audio matrix
DVD player
Desktop Microphone with zone selector
Wireless Microphone
Wireless reciever
24U Public address rack
Sound attenuator
Supplying, installing, connecting , programming and testing of addressable fire alarm control panel (FACP), 3 Loops Complete
Supply, installation, connecting and testing of Addressable smoke detector along with the connecting base.
Supply, installation, connecting and testing of Addressable heat detector with the connecting base.
Supply, installation, connecting and testing of Addressable multi discipline detector with the connecting base.
Supply, installation, connecting and testing of Manual pull break glass unit with the connecting base.
Supply, installation, connecting and testing of Addressable warning sounder with the connecting base.
Supply, installation, connecting and testing of Addressable warning sounder weather proof with the connecting base.
Supply, installation, connecting and testing of MONITORING MODULE
Supply, installation, connecting , testing and commissioning of CONTROL MODULE
Supply, installation, connecting , testing and commissioning of check in / check out monitoring system for the school employe
free finger print , password or proximity passive cards , life time , can be locally programmed or through PC, connected to the
PB-ER with main breaker 63/100A ,With outgoing 18 branch circuit
TYPE F11
TYPE F11E
TYPE F14
Supply , installation and testing of wall mounted single socket outlet, 13A, 220V, IP66, weather proofing for outdoor areas,as i
four core cable , 4C 10 mm2 CU/XLPE/PVC + earthing cable , 1C *6 mm2 Cu/PVC .
Supply, installation, operation and testing of the grounding system for the electrical room with the main ground network conn
Supply, installation, connecting and testing of Addressable multible detector with the connecting base.
PB-MG Flush Mounted Panel Board of 30 Ways, Main Breaker of 100AT/100AF, 3P, 60Hz, IP42 TO control external and site ligh
TYPE F11
TYPE F11E
TYPE F6
TYPE F6E
TYPE F14
Supply , installation and testing of wall mounted single socket outlet, 13A, 220V as indicated in the specs and drawings.
Supply , installation and testing of double socket outlet, 13A, 230V
Supply , installation and testing of Double pole switch, 20A, 220V for EWH with indicating lamp with the letters (WH) , the item
Supply , installation and testing of Double pole switch, 45A, 220V for indoor Evapurating units , wall mounted split units , the
Supply , installation and testing of Non-fusible disconnect switch, (30A, 2P, 230V, IP 65)
wall mounted Telephone Outlet including conduits, cat3 cables , RJ11 type
Data outlet wall mounted
Data outlet mounted within the gate
Supply, installation, connecting and testing of Addressable smoke detector along with theconnecting base.
Supply, installation, connecting and testing of Manual pull break glass unit with the connecting base.
Supply, installation, connecting , testing and comissioning of aire alarm repeater FARP as per specs , standard , drawing and en
Microphone
PB-CTN Flushoutlet
Mounted Panel Board of 18 Ways, Main Breaker of 40/100 AF, 3Ph, 60Hz, IP 10, Branches

TYPE 2F
TYPE 3F
Supply , installation and testing of double socket outlet, 13A, 230V
Supply , installation and testing of double socket outlet, 15A, 230V
Supply , installation and testing of Double pole switch, 20A, 230V for EWH with indicating lamp with the letters (WH) , the item
Supply , installation and testing of Double pole switch, 45A, 230V for indoor Evapurating units , wall mounted split units , the
Supply , installation and testing of Double pole Diconnecting switch,( 30A,2P, 230V,IP65) for Outdoor units units , wall mounte
Telephone Outlet
Supply, installation, connecting and testing of Addressable heat detector along with the connecting base.
Supply, installation, connecting and testing of Addressable smoke detector along with the connecting base.
Supply, installation, connecting and testing of Manual pull break glass unit with the connecting base.
TYPE F11E
Single power socket outlet, 13A, 220V, weather proof, IP65
Supply , installation and testing of Non-fusible disconnect switch, (60A, 2P, 230V, IP 65)
Supply , installation and testing of Non-fusible disconnect switch, (160A, 4P, 400V, IP 65) , the current rating and the connectio
Supply and install addressable multi Fire alarm system (smoke and heat detectors)
Location BoQ Buhaira ABL Comments
General Site 1 0.1 0 ABL have paid the fees
General Site 1 1 0 ABL have made the connection via third party
General Site 3 4 0
General Site 3 4 0
General Site 0 0 0
General Site 150 142.5 0
General Site 100 96 0
General Site 90 92 0
General Site 170 193 0
General Site 0 0 0
General Site 45 52.6 0
General Site 10 8.1 0
General Site 0 6.5 0
General Site 10 0 60
General Site 0 72 95
General Site 6 10 0
General Site 10 5 0
General Site 2 23 0
General Site 3 3 0
Main Building 2 2 0
Main Building 1 1 0
Main Building 1 1 0
Main Building 1 1 0
Main Building 1 1 0
Main Building 1 1 0
Main Building 250 303 0
Main Building 50 9 0
Main Building 39 38 0
Main Building 12 10 0
Main Building 16 15 0
Main Building 0 7 0
Main Building 86 85 0
Main Building 24 23 0
Main Building 0 16 14
Main Building 7 6 0
Main Building 3 2 0
Main Building 13 12 0
Main Building 89 83 0
Main Building 72 81 0
Main Building 4 4 0
Main Building 2 2 0
Main Building 3 4 0
Main Building 0 1 0
Main Building 6 7 0
Main Building 23 24 28 Price of SB related Acs
Main Building 3 2 0
Main Building 4 4 0
Main Building 100 102 0 Frame
Main Building 0 5 0
Main Building 0 1 0
Main Building 2 2 0 VO
Main Building 0 196.2 0
Main Building 0 70.8 0
Main Building 1 1 0
Main Building 8 19 0
Main Building 1 1 0
Main Building 1 1 0
Main Building 6 7 0
Main Building 1 1 0
Main Building 6 7 0 Cable Tray
Main Building 102 99 92 UTP/STP 25 years Warranty
Main Building 1 1 0
Main Building 1 1 0
Main Building 32 30 0
Main Building 8 5 0
Main Building 9 9 0
Main Building 2 2 0
Main Building 1 1 0
Main Building 20 14 0
Main Building 10 6 0
Main Building 3 3 0
Main Building 1 1 0
Main Building 1 1 0
Main Building 1 1 0
Main Building 1 1 0
Main Building 3 3 0
Main Building 1 2 0
Main Building 1 1 0
Main Building 1 1 0 have to install it
Main Building 1 1 0
Main Building 68 63 0
Main Building 2 0 1 Guardroom
Main Building 1 3 0
Main Building 10 11 0
Main Building 10 13 0
Main Building 1 1 0
Main Building 2 6 0
Main Building 1 4 0
Main Building 1 1 0
Electrical Roo 1 1 0
Electrical Roo 1 1 2
Electrical Roo 1 1 0
Electrical Roo 1 1 0
Electrical Roo 5 2 0
Electrical Roo 10 9 0
Electrical Roo 1 1 0
Electrical Roo 1 1 0
Girls Gate 1 1 0
Girls Gate 2 1 0
Girls Gate 2 1 0
Girls Gate 2 1 0
Girls Gate 2 2 0
Girls Gate 3 11 0
Girls Gate 3 3 0
Girls Gate 3 3 0
Girls Gate 1 1 0
Girls Gate 1 3 0
Girls Gate 1 1 0
Girls Gate 1 1 0
Girls Gate 1 1 0
Girls Gate 0 1 0
Girls Gate 1 1 0
Girls Gate 1 1 0
Girls Gate 1 1 0
Girls Gate 1 1 0
Canteen 1 1 0
Canteen 2 2 0
Canteen 4 7 0
Canteen 4 4 0
Canteen 4 4 0
Canteen 1 1 0
Canteen 1 2 0
Canteen 1 1 0
Canteen 1 1 0
Canteen 1 1 0
Canteen 1 1 0
Canteen 1 1 0
Water Tank 2 2 1
Water Tank 4 4 2
Water Tank 1 1 0
Water Tank 1 1 0
Water Tank 1 1 0