1. The present practicable limits of radio frequency are 10 kHz to 100,000 MHz.

2. In a building emergency communication system where ac power source is monitored


for integrity should be tested Annually system where ac power source is not monitored
for integrity should be tested Quarterly.

3. Lighting used to charge photoluminescent materials shall not be controlled by Motion


sensor.

4. The two-way communication system shall include both Audible and Visible signals.

5. A device that detects visible or invisible particles of combustion . – Smoke Detector

6. A radiant energy–sensing fire detector that detects the radiant energy emitted by a
flame. - Flame Detector

7. A fuel tank, located inside a structure, that provides fuel to the engine. - Day Fuel
Tank

8. A separate, main fuel tank for supplying fuel to the engine or a day tank. - Main Fuel
Tank

9. During conditions of stair use, the minimum illumination for new stairs shall be at least
___ measured at the walking surfaces. - 10 ft-Candle (108 lux)

10.The minimum illumination for floors and other walking surfaces, other than new stairs
during conditions of stair use, shall be to values of at least ______measured at the floor.
- 1 ft-candle (10.8 lux)

11.Where maintenance of illumination depends on changing from one energy source to


another, a delay of not more than ____ shall be permitted. - 10 Second

12.The maximum-to-minimum illumination shall not exceed a ratio of 40 to 1.

13.Device with alphanumeric display _____? - Visible annunciation

14.Visual inspection of heat detector _____? - Semiannually

15.The visual representation of output data, other than printed copy. - Display

16.The radio signal from the base station transmitter to the portable public safety
subscriber receiver. - Downlink

17.The fire alarm system operation is same as it is design in which condition.

A. Pre-Alarm B. Normal C. Trouble D. Supervisory

1. Manual Fire alarm boxes shall be located within ______ of each exit doorway on each
floor. - 5 ft (1.5 m)

2. A notification appliance that alerts by the sense of touch or vibration. - Tactile


notification appliance

3. A control function that attempts to return a system or device to its normal, nonalarm
state. - Reset

4. Battery calculations shall include a minimum ______ safety margin above the calculated
amp-hour capacity required. - 20%

5. Required signals shall not be lost, interrupted, or delayed by more than ___ as a result
of the primary power failure. - 10 Seconds

6. Testing of engine-driven generator _______? - Monthly

7. High-frequency energy that can be modulated by voice or signaling impulses. - Carrier


8. A system intended to page one or more person by such means as voice over loud
speaker, coded audible signals or visible signals, or lamp annunciators. - Paging
system

9. A system component that provides interface between signaling line circuits, initiating
device circuits, or control units and the transmission channel. - Transmitter

10.Any alarm that occurs that is not the result of a potentially hazardous condition. -
Unwanted Alarm

11.The secondary power supply shall have sufficient capacity to operate the system under
quiescent load (system operating in a non-alarm condition) for minimum of _____. - 24
HRS

12.The installation of all pathway wiring, cable, and equipment shall be in accordance with
____. - NFPA 70

13.What is the color code for an ordinary temperature classification heat-sensing detector?
- Uncolored

14.What is the color code for initiating device at normal operation? - Uncolored

15.stored energy system has the capability to start the prime mover without using energy
from another source. - Black start

16.The EPS shall be installed in accordance with ____________. - NFPA 70

17.What are the maximum capacities shall be permitted for integral tanks? - 1) Maximum
of 2498 L (660 gal) diesel fuel, 2) Maximum of 95 L (25 gal) gasoline fuel

18.Transfer switch shall be operated __________ - Monthly

19.What device are normally indicated on the mimic panel with LED which graphically
indicates the building the floor and location of fire?

A) Manual call points, Flow Switch, Detectors C) Bell, Horn and


Strobes

B) Control Panel & Fire Telephone D) Exit Signs, Sounder


Device

1. The principal attended, or unattended location where the status of detection alarm
communication and control system is displayed and from which the system (s) can be
manually controlled?

A) Fire Pump Room C) Mechanical Room

B) Fire Command Centre D) Electrical Room

1. Battery calculation for a protected premise for fire alarm system require how much
reserve capacity for safety margins?

A) 10 % C) 5 ampere-hours

B) 20 % D) No Factor of safety is
mandated by the code

1. Secondary power supply batteries are required to be marked with:

A) The system’s ampere-hours requirements (battery calculation result)

B) The date installed D) The maximum


available short circuit current

C) The date Manufactured using the month/year format.


1. A wiring classification of circuits NOT capable of transmitting an alarm signal beyond a
single open or during a short between conductors.

A) CLASS A C) CLASS C

B) CLASS B D) CLASS X

1. Equipment connected to a fire alarm circuit must be listed:

A) By underwriter laboratories C) For use with control


unit

B) For fire alarm use D) For the purpose for


which it is listed

1. Emergency illumination shall be provided for a minimum of ______hours in the event of


failure of normal lighting. - 1.5 HRS

2. Emergency generators providing power to emergency lighting systems shall be


installed, tested, and maintained in accordance with________. - NFPA 110

3. The operable part of manually actuated alarm initiating device shall be not less than
_______ and not more than ________ from the finished floor. - 42 in. (1.07 m) / 48 in.
(1.22 m)

4. Trouble signals and their restoration to normal shall be indicated within _____. - 200
seconds

5. Restoration of latching supervisory signals shall be indicated within _______. - 90


seconds

6. The marking stripe shall have a minimum width of ______. - 1 in. (25 mm)

7. The emergency exit symbol applied on the door shall be a minimum of ______. - 4 in.
(100 mm)

8. The word EXIT shall be in letters of a width not less than________ and the minimum
spacing between letters shall be not less than_____. - 2 in. (51mm) 3/8 in (9.5
mm)

9. Externally illuminated signs shall be illuminated by not less than______. - 5 ft candles


(54 lux)

10.Devices that detect a phenomenon other than heat, smoke, flame, or gases produced
by a fire. - Other Fire Detector

11.A device that responds when the temperature rises at a rate exceeding a
predetermined value. - Rate-of-Rise Detector

12.The branch circuit(s) and connections shall be protected against physical damage. -
Mechanical Protection

13.The number of supervisory signals–initiating devices permitted to be connected to a


single initiating device circuit shall not exceed ____. - 20

14.A signal-transmitting station shall be provided at intervals not exceeding ___


intermediate stations. - 10

15.For testing all emergency lighting and power system during maximum anticipated load
condition shall be provided in which condition? - Testing under load

16.A device designed to close, open, or both, one or more electrical circuits. - Switching
Device
17.A power supply used to provide alternating current power to load for some period of
time in the event of a power failure. - Uninterruptible Power Supply (UPS)

18.A compartment or chamber to which one or more air ducts are connected and that
forms part of the air distribution system. - Plenum

19.An enclosed channel of metallic or nonmetallic materials designed expressly for holding
wires, cables, or bus bars, with additional function as permitted. - Raceway

20.The maximum current, in amperes, that a conductor can carry continuously under the
conditions of use without exceeding its temperature rating. - Ampacity

21.The circuit conductors between the final overcurrent device protecting the circuit and
the outlet(s). - Branch Circuit
22.A conducting object through which a direct connection to earth is established. -
Grounding Electrode
23.The operable part of manually actuated alarm initiating device shall be not less than
_______and not more than _________ from finished floor. - 42 in (1.07 m) / 48 In (1.22
m)

24.The off-normal signal shall be initiated when the required pressure increases or
decreases by ____. - 10 psi (70 kPa)

25.For the purpose of alarm annunciation, each floor of the building shall be considered as
a separate zone.

26.What is the required secondary power capacity (battery requirement), if the total
system standby current draws 0.177 amperes operating 24 hours and with total
system alarm current of 3.32 amperes that can operate the system for at least 5
minutes with a safety factor of 20 percent?

A) 2 AMP-HR C) 6 AMP-HR

B) 4 AMP-HR D) 8 AMP-HR

1. A wiring classification of circuits capable of transmitting an alarm signal during a single


open or non-simultaneous ground fault on a conductor.

A) CLASS A C) CLASS C

B) CLASS B D) CLASS X

1. A fire alarm system required for life safety shall be installed, tested, and maintained in
accordance with applicable requirements of_____? - NFPA 70 National Electrical
Code / NFPA 72 National Fire Alarm Code

2. A device used to store and generate a sinusoidal wave. - Generator.

3. All fuel tanks and system shall be installed and maintain in accordance with ______. -
NFPA 30

4. A type of energy conversion equipment (ECE) intended to temporarily support the


critical load with stored energy until an alternate energy source can assume the load. -
Bridging System

5. The flash rate shall not exceed two flash per second (2 Hz) nor be less than one
flash per second (1 Hz).

6. A maximum pulse duration shall be 0.2 second with a maximum duty cycle of 40%.
7. Emergency illumination shall be provided for not less than 1 1/2 hours in the event of
failure of normal lighting.

8. Where maintenance of illumination depends on changing from one energy source to


another, a delay of not more than 10 seconds shall be permitted.

9. Emergency lighting facilities shall be arranged to provide initial illumination that is not
less than an average of 10.8 lux (1 ft-candle) and, at any point, not less than 1.1 lux
(0.1 ft-candle), measured along the path of egress at floor level.

10.Fire alarm system required for life safety shall be installed, tested, ...accordance with
applicable requirements of NFPA 70.

11.Equipment enclosed in a case that is capable of withstanding an explosion of a


specified gas or vapor that may occur within it and of preventing the ignition of a
specified gas or vapor surrounding the enclosure by sparks, flashes or explosion of the
gas or vapor within and that operates at such an external temperature that a
surrounding flammable atmosphere will not be ignited thereby‐Explosion proof
Equipment.

12.What devices are normally indicated on the mimic panel with LED which graphically
indicates the building the floor and location of fire‐ Manual Call Points, Flow switch,
Detectors

13.In a high rise building two-way hard-wired telecommunications are required at – All of
the above (Fire pump room, Elevator car & lift lobby, Fire command center).

14.A visible signaling lights used for fire alarm signaling, only or to signal the intent for
complete evacuation shall be _____________and shall not exceed 1000 Candle’s – Clear
or Normal white.

15.The minimum distance allowed for detector to be positioned to a corner of a room on a


smooth ceiling is – 60% minimum spacing between detectors

16.What is the color code for an ordinary temperature classification heat sensing fire
detector –Red.

17.which is the secondary power capacity (battery requirement) if the total system
standby current draws 0.177ampheres operating 24 hours and with total system alarm
current of 3.32 amperes that can operate the system for at least 5 minutes with a
safety factor of 20 percent‐ 6 Amp‐hr.

18.A thin layer of construction material. – Membrane.

19.To ensure that audible public mode signals are clearly heard, … they shall have a sound
level at least 15 dB above the average ambient sound level or 5 dB above the
maximum sound level having a duration of at least 60 seconds.

20.Failure of primary power shall not loss, interrupt or delay the required signals for how
many seconds‐ 10 Seconds.

21.Audible appliances for sleeping areas shall have a sound level of at least 75dBA having
a duration of 60 seconds.

22.Visual and audible means to indicate a 15 percent or greater reduction of normal


power supply (rated voltage) shall be provided .

23.The location of the emergency control function interface device within 3 ft (0.9 m)
applies to the point of interface and not to remotely located equipment.
24.A publicly accessible alarm box that can also be operated by one or more remote
initiating devices or an auxiliary alarm system used to send an alarm to the
communication center. – Master Alarm Box

25.The branch circuits and connections shall be protected against physical damage. –
Mechanical Protection

26.For wireless network boxes the battery shall have power to sustain operation for a
minimum period of 15 days without recharging.

27.A directional indicator shall be identifiable as a directional indicator at a distance of 40


ft (12 m).

28.The principle of using automatic analysis of real time video images to detect presence
of flame –

video image flame detection.

29.An audible or visible signal that conveys several discrete bits or units of information –
Coded

30.An average ambient sound level greater than 105 dBA shall require the use of visible
notification appliance.

31.The total sound pressure level produced by combining the ambient sound pressure
level with all audible notification appliance operating shall not exceed 110dBA.

32. Public mode audible requirements –They shall have a sound level at least 15 dB
above the average ambient sound level and 5 dB above maximum sound level
having duration of at least 60 seconds.

33. Private mode audible requirements –They shall have a sound level at least 10 dB
above the average ambient sound level and 5 dB above maximum sound level
having duration of at least 60 seconds.

34. Fuses rated at 3 amperes minimum to 7 amperes maximum and not less than
2000 volts.

35. A fire alarm system component with discrete identification that can have its status individually
identified or that is used to individually control other functions. -- Addressable device.

36. A system component that monitors inputs and control outputs through various types of
circuits. – Control unit.

37. Any circuit, conductor, optic fiber, radio carrier, or other means connecting two or more
location. – Path (pathway).

38. A grandstand in which the seats are not provided with backrests -Bleachers.

39. Illuminated by self-contained power source and operated independently of external power
sources. – Self-Luminous.

40. A material that, in the form in which it is used and under the conditions anticipated, will not
ignite, burn, support combustion, or release flammable vapors when subjected to fire or heat
– Noncombustible Material

41. The separation shall have a minimum 1-hour fire resistance rating where the exit connects
three or fewer stories.

42. The separation shall have a minimum 2-hour fire resistance rating where the exit connects
four or more stories.
43. The emergency exit symbol applied on the door shall be a minimum of 4 in. (100 mm) in
height and shall be applied on the door, centered horizontally, with the top of the symbol not
higher than 18 in. (455 mm) above the finished floor.

44. In assembly occupancies, the illumination of the walking surfaces of exit access shall have be
at least 0.2 ft-candle (2.2 lux).

45. The emergency lighting equipment shall automatically perform annually a test for a minimum
of 1 1/2 hours.

46. The total quantity of combustible contents of a building, space, or fire area. – Fuel load.

47. Vestibules shall have a dimension of not less than 44 in. (1120 mm) in width and not less
than 6 ft (1830 mm) in the direction of travel.

48. Externally illuminated signs shall be illuminated by not less than 5 ft-candles (54 lux) at the
illuminated surface and shall have a contrast ratio of not less than 0.5.

49. A stage with a height greater than 50 ft (15 m) measured from the lowest point on the stage
floor to the highest point of the roof or deck above. – Legitimate stage.

50. Day tank on diesel systems shall be installed below the engine fuel return elevation.

51. Test the device in place to ensure CO entry to the ______ by introducing through the vents to
the sensing chamber. – sensing chamber

52. What does class 6 in EPSS stand for. - 6 hrs. minimum

53. Fault in the fire alarm or signaling system. – Trouble condition

54. What does FPLP stand for. – power limited fire alarm plenum cable

55. For a diesel engine powered EPS, loading should not be less than _-of nameplate KW rating pf
the EPS. – 30%

56. Type of detector by introducing smoke or another aerosol or an optical filter in to the beam
path. – Projected beam type

57. Test _____ in place to ensure smoke entry in to the sensing chamber and alarm response. –
Smoke detector

58. Emergency communication system periodic maintenance. – Annually

59. A horizontally measured dimension related to the allowable coverage of fire detector. –
Spacing

60. The location of the equipment needed to relay signals between supervising stations,
subsidiary station, and protected premises. - Repeater station
61. A hearing threshold of greater than 90 dB- Profound Hearing Loss
62. A message indicating a condition, communicated by electrical, visible, audible, wireless, or
other- Signal