Workshop Hz.-Vl.-Irregularity

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 7

Check of irregularity

1- Horizontal irregularity :

A Amplifi cation of Accidental


Ax
Torsional Moment

TABLE: Story Max/Avg Displacements


Story Load Case/Combo Direction Max Avg Ratio Ratio Check
Ax e
mm mm (disp.) (drift)
Second Ex+ECC X 12.934 12.082 1.071 1.045 NO Torsional irregularity - -
First Ex+ECC X 9.132 8.102 1.127 1.279 torsional irregularity 0.8822361 0.044112

TABLE: Story Max/Avg Displacements


Story Load Case/Combo Direction Max Avg Ratio Ratio Check
Ax e
mm mm (disp.) (drift)
Second Ex-ECC X 13.987 12.21 1.146 1.24 torsional irregularity 0.9112873 0.045564
First Ex-ECC X 8.914 8.108 1.099 1.331 torsional irregularity 0.8393736 0.041969

TABLE: Story Max/Avg Displacements


Story Load Case/Combo Direction Max Avg Ratio Ratio Check
Ax e
mm mm (disp.) (drift)
Second Ey+ECC Y 11.268 9.953 1.132 1.13 NO Torsional irregularity - -
First Ey+ECC Y 7.863 6.925 1.136 1.453 torsional irregularity 0.8953122 0.044766
TABLE: Story Max/Avg Displacements
Story Load Case/Combo Direction Max Avg Ratio Ratio Check
Ax e
mm mm (disp.) (drift)
Second Ey-ECC Y 10.617 9.89 1.074 1.08 NO Torsional irregularity - -
First Ey-ECC Y 7.383 6.883 1.073 1.419 torsional irregularity 0.7990017 0.03995

TABLE: Story Max/Avg Displacements


Story Load Case/Combo Direction Max Avg Ratio Check
Ax e
mm mm
Second Ex+ECC X 12.934 12.082 1.071 1.045 NO Extreme Torsional irregularity - -
First Ex+ECC X 9.132 8.102 1.127 1.279 NO Extreme Torsional irregularity - -

TABLE: Story Max/Avg Displacements


Story Load Case/Combo Direction Max Avg Ratio Check
Ax e
mm mm
Second Ex-ECC X 13.987 12.21 1.146 1.24 NO Extreme Torsional irregularity - -
First Ex-ECC X 8.914 8.108 1.099 1.331 NO Extreme Torsional irregularity - -
TABLE: Story Max/Avg Displacements
Story Load Case/Combo Direction Max Avg Ratio Check
Ax e
mm mm
Second Ey+ECC Y 11.268 9.953 1.132 1.13 NO Extreme Torsional irregularity - -
First Ey+ECC Y 7.863 6.925 1.136 1.453 Extreme Torsional irregularity 0.8953122 0.044766

TABLE: Story Max/Avg Displacements


Story Load Case/Combo Direction Max Avg Ratio Check
Ax e
mm mm
Second Ey-ECC Y 10.617 9.89 1.074 1.08 NO Extreme Torsional irregularity - -
First Ey-ECC Y 7.383 6.883 1.073 1.419 Extreme Torsional irregularity 0.7990017 0.03995

Reentrant corner irregularity not exist , since the plan is regular and there is no reentrant corner in the plan .
Diaphragm discomtinuity irregularity not exist , since there is no open area greater the the area of the plan

Out-of-plane offsets irregularity not exist , since there is no discontinuity in a lateral force-resistance path .

Nonparallel systems irregularity not exist , since vertical lateral force-resisting elements are
parallel to the major orthogonal axes of the seismic force-resisting system.
Check of irregularity
2- Vertical irregularity :

TABLE: Story Stiffness X-Direction


Stiffness X -etabs 𝐾𝑖/(𝐾𝑖+1) 𝐾𝑖/((𝐾𝑖+1+𝐾𝑖+2+𝐾𝑖+3))
Story Load Case check > 0.7 check > 0.8
kN/m
Roof Ex 174916.668 - - - -
First Ex 439188.929 2.51084664 ok - -

TABLE: Story Stiffness Y-Direction


Stiffness y -etabs 𝐾𝑖/(𝐾𝑖+1) 𝐾 (𝐾 + +𝐾 +𝐾 ))
Story Load Case check > 0.7 𝑖/( 𝑖 1 𝑖+2 𝑖+3 check > 0.8
kN/m
Roof Ey 703.5175 - - - -
First Ey 1393.896 1.98132385 ok - -

TABLE: Story Stiffness X-Direction


Stiffness X -etabs 𝐾𝑖/(𝐾𝑖+1) 𝐾 (𝐾 + +𝐾 +𝐾 ))
Story Load Case check > 0.6 𝑖/( 𝑖 1 𝑖+2 𝑖+3 check > 0.7
kN/m
Roof Ex 174916.668 - - - -
First Ex 439188.929 2.51084664 ok - -

TABLE: Story Stiffness Y-Direction


Stiffness y -etabs 𝐾𝑖/(𝐾𝑖+1) 𝐾 (𝐾 + +𝐾 +𝐾 ))
Story Load Case check > 0.6 𝑖/( 𝑖 1 𝑖+2 𝑖+3 check > 0.7
kN/m
Roof Ey 703.5175 - - - -
First Ey 1393.896 1.98132385 ok - -

TABLE: Centers of Mass and Rigidity


Story Mass X Mass Y Check for x -direction Check for y -direction
𝑚𝑖/(𝑚𝑖+1)& 𝑚𝑖/(𝑚𝑖−1)𝑚𝑖/(𝑚𝑖+1)&
<1.5 𝑚𝑖/(𝑚𝑖−1) <1.5
kg kg
First 3617479 3617479.13 Mass irregularity Mass irregularity
Second 2158786 2158785.84 No mass irregularity No mass irregularity
Since the structure is seismic design category ( C ) , the Equivalent Lateral
Force Analysis is permitted for all structures of seismic category B & C as per Table
12.6-1
Vertical geometic irregularity not exist , since the building is regullar in the elevations .

In-Plane Discontinuity in Vertical Lateral Force-Resisting Element Irregularity not exist , since there is no an in-
plane offset of a vertical seismic force-resisting element resulting in overturning demands on a supporting
beam, column, truss, or slab.

Since all the columns and core has no increase in the dimensions or reinforcement from the bottom of building
to the top of the building ,there is no weak or extreme weak story