PROBLEMS

3'1'A fully-restrainedbearn 457 x 191 x 67 UB is intendedto carry 25


kN/m of dead load and l0
kN/m of live load. The beamis simply supportedand spanningover
6m. Checkthe adequacyof
the beamin termsof moment capacity,sheaicapacity*i d"fl"Itiorr.
Use steelof Grade5275.
3'2'A beam is subjectto the loadingsas shown in Figure 3.33. Design
the beambasedon the most
economicalsectionand checkfor its adequacy.Use steelof Grade5355.

Gr :80 kN
pr :60 kN
7 kN/m
5 kN/m

. 4m 6m

Figure 3.33

3'3'Designthe cantileverbeamwith the most economicalsectionasdepicted


in Figure3.34. Use steel
ofGrade3275.

Gt=50kN
=
ar 40 k].,1

Figure 3.34

3'4'A second-floorslab o-fan office building is shownin Figure 3.35.


Designto the most economical
sectionfor the following beamsbasedon the given loadi

Deadload :3.6 kN/m2


Live load :2.5 kN/m2
Load dueto brick wall : 7.5kN/m
Usesteelof Grade5275.

a) BeamCl2-3
b) Beam3/B-D (brickwall is locatedon this beam)

3-38
o
3m

rn
\7

6m

o
3m

o
JM

(,

Figure 3.35

3.5.A 7-metre spannedsimply supportedbeam is to be built under the constraintslisted below.


Proposea suitablesectionto fit the requirements
below:-

o The beam should be able to carry the uniform unfactoreddead load of 35 kN/m and
unfactoredlive load of 25kN/m alongthe beam
o The depth ofthe beamshouldnot exceed500 mm
o The beam is fully restrainedwith both endsconnectedto the column by a pin jointed
connection.
o Usesteelofgrade 3355.

3-39