AADN 210622 AMSA inspection feedback at Melbourne

AMSA inspection feedback at Melbourne, Australia


Inspection date: 22nd Jun. 2021
Inspection time: 1050LT – 1330LT
Inspector : Mr. Darryl A. F. Rosairo

Documentation
1. Inspected all certificates
-Last PSC inspection report
-Officer and Crew certificates of Competency with STCW endorsements and Certificates of Recognition
-ECDIS Certification and License
-Document of Compliance (Dangerous Goods)
-Annual Test Reports : EPIRP, AIS, VDR
-Shore Based Maintenance Agreement (Radio Equipment)
-Copy of Watch Schedule (at Sea and In port) and Hours of Rest Records
-P&I Certificate of Entry
-Continuous Synopsis Record
-Civil Liability Insurance (Bunker)

2. Inspected all record book


- Garbage record book
- Ballast water record book
- Oil record book
- Drill record (Especially L/B launching drill & Enclosed entry drill)
- Work and rest hour record book (Current & Last year)
- LSA & FFA maintenance record book
- Deck & Engine log book
-Cargo gear record book

3. Crew familiarization of MLC & proper procedure for Onboard Complaint


4. Cargo Securing Manual
5. SOPEP manual

Rounding – Bridge
1. Gyro error and magnetic compass deviation
2. Passage plan and ECDIS setting value : Safety contour/Deep contour/Sallow depth/Safety depth
3. GMDSS log gook and Carried out MF/HF test with Canberra JRCC on scene
4. Daylight Signal
5. ECDIS IHO 4.0 Standard
6. VDR alarm check
7. AMSA MSI message
8. FDS alarm status
9. Light indication of bridge console and panel
10. GDMSS Antenna visual check
11. VDR floating capsule reflection tape
12. Em’cy steering test by engineer
13. Air horn test by pulling manual line

Rounding – Deck
1. Emergency fire pump (Operation by two lines (Fwd & Aft)
2. Rescue boat engine test including battery 1&2 testing
3. Rescue boat davit test (Normal & em’cy operation)
4. Life boat engine test including battery 1&2 testing
5. Lifeboat proper launching procedures & emergency procedures (Crew familiarization)
6. Cargo hold fan damper condition randomly (Open & Close)
7. All E/R fan damper condition (Open & Close)
8. Life raft davit & off-load release hook (Crew familiarization)
9. Bosun Store inspection (Checking Em’cy towing booklet)
10. Paint store inspection (Eye wash & Explosion proof lamp)
11. Deck lights & Emergency lights condition
12. CO2 room inspection (proper markings & Crew familiarization)
13. Mooring station general condition
14. Condition of Mooring lines, Rat guard, & break lining of mooring winches including windlass
15. Funnel damper condition (Open & Close)
16. Watertight door condition
17. Fire box condition (inside)
18. Fireman’s outfit & SCBA condition in Fire control room
19. Embarkation ladder condition (End Shackle/Eye)

Rounding – Galley
1. Cleanness condition (especially Oil inside cooking hood)
2. All faucets condition
3. Food waste management
4. Fruit & vegetable Q’ty & condition
5. Old cooking oil disposal
6. Ozone water purifier condition & replacement of filter

Rounding – Engine room


1. Tested EM’CY G/E by hydraulic starter and battery start
2. Checked steering gear room gyro compass condition
3. Checked cleaning condition S/G side
4. Checked SCBA pressure, low pressure alarm in fireman's outfit cabinet of steering gear room
5. Checked water level gauge condition of aux. boiler and cleaning condition of aux. boiler each pump
side
6. Checked cleaning condition of each F.O pump & purifier side
7. Checked Control panel of water mist local firefighting system (No test)
8. Checked cleaning condition of HT&LT cooler side (sea water pipe)
9. Checked cleaning condition of M/E (M/E F.O high press. Pipe side/insulation condition)
10. Tested self-closing condition of each sounding pipe in E/R (random check)
11. Checked running condition of blower for sewage treatment system.
12. Checked cleaning condition of tank top & bilge well
13. Checked running condition of Main cooling sea water pump
14. Tested 15ppm alarm & OVBD 3-way valve for O.W.S and check alarm list
15. Checked seal condition of bilge & sewage OVBD valve
16. Checked condition of 220V, 440V & 24V insulation in ECR.