Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

CONCRETE COMPRESSIVE STRENGTH TEST REPORT NF EN

12390-3
Number of Test Report 005
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima

Temperature weather /
28,2 / 30,1 °C Size of specimen 160 x 320 mm
concrete
Pouring date 6/13/2023 Slump test at 0' 15,6 cm
Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
Quantity(Kg/m3) 450 178.78 574 260 1018 4
Part of Structure

Production Line Shed / Footing / A3IF01-D1IF03

30A100_RFI_17 EXT
Number notification Date of receipt 6/15/2023
30A100_RFI_38 EXT

Curing by Density Strength (Mpa)


Spec. Tag Crushing date Weight (Kg) Load (kN)
days (T/m3)
Unit Average
AH016 16.16 2.51 403.50 20.07
AH017 7 6/20/2023 16.14 2.51 327.53 16.29 19.82
AH018 16.22 2.52 464.49 23.10
AH019 16.28 2.53 547.27 27.22
AH020 28 7/11/2023 16.26 2.53 511.82 25.46 26.67
AH021 16.34 2.54 549.81 27.35

Inspection execution result


ACCEPTED ⃣ REJECTED ⃣ POSTPONED ⃣ CANCELLED ⃣
Remarks :

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date