CONCRETE COMPRESSIVE STRENGTH TEST REPORT NF EN

12390-3
Number of Test Report 002
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima
Mix Design Trial Mix ✘ Control Information

Temperature weather /
31,2 / 32,2 °C Size of specimen 160 x 320 mm
concrete
Pouring date 6/2/2023 Slump test at 0' 9,2 cm
Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
Quantity(Kg/m3) 450 178.78 574 260 1018 4
Part of Structure
N/A

30A100_RFI_14 EXT
Number notification Date of receipt 6/5/2023
30A100_RFI_29 EXT

Curing by Density Strength (Mpa)


Spec. Tag Crushing date Weight (Kg) Load (kN)
days (T/m3)
Unit Average
TM07 15.74 2.45 434.43 21.61
4 6/6/2023 20.19
TM08 15.66 2.44 377.52 18.78
TM09 15.82 2.46 474.41 23.60
7 6/9/2023 22.95
TM10 15.54 2.42 448.52 22.31
TM11 15.78 2.45 485.00 24.12
14 6/16/2023 25.28
TM12 15.74 2.45 531.59 26.44
TM13 15.86 2.47 501.60 24.95
33 7/5/2023 27.14
TM14 15.64 2.43 589.62 29.33

Inspection execution result


ACCEPTED ⃣ REJECTED ⃣ POSTPONED ⃣ CANCELLED ⃣
Remarks :

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date