Spectra - Paradox - Alarm System - Connection Diagram
Spectra - Paradox - Alarm System - Connection Diagram
Status LED
Flash once every sec: Normal
operation
Four pin connector can be Toggle ON 1 sec/OFF 1 sec: Trouble
used for quick installation of a in the system
Spectra keypad or Expansion Always on: Panel is using phone
Module. line
Fast flash 4 sec after power up:
Installer Lock enabled
Disconnect battery
before replacing the fuse.
SPECTRA KEPADS
• The maximum number of keypads per installation is dependent on the
BELL OUTPUT auxiliary output, which is not to exceed 700mA.
Will shut down if current • Warning: Do not connect keypads more than 250ft (76m) from the control
exceeds 3A. panel.
• For the
keypad’s
zone, EOL and
tamper
configurations,
refer to
Configuring the
LED Keypads
on page 9.
AUX POWER
To connect additional wiring to auxiliary power, use the red A Door Contact or any other
(+) and black (-) keypad connectors. Auxiliary power will detection device can be
shut down if current exceeds 1.1A. If the auxiliary output is connected to the Keypad Zone.
overloaded and is shut down, you must disconnect all
loads from the output for at least 10 seconds before
reconnecting any load back to the auxiliary output.
Spectra Series 3