Figure 2: Spectra 1728 Control Panel Overview

Reset Jumper Paradox Memory Key

Status LED
Flash once every sec: Normal
operation
Four pin connector can be Toggle ON 1 sec/OFF 1 sec: Trouble
used for quick installation of a in the system
Spectra keypad or Expansion Always on: Panel is using phone
Module. line
Fast flash 4 sec after power up:
Installer Lock enabled

Disconnect telephone line


before servicing.

Disconnect battery
before replacing the fuse.

Refer to PGMs for


1728 on page 5
See Single Zone Inputs or
Double Zone Inputs (with
Refer to the Transformer ATZ Option only) on page 6 Cold water
Requirements Table on pipe
page 4 AWG#14 single grounding
conductor solid
copper wire
Ground
Improper connection clamp
may result in damage
To provide maximum lightning
to the system.
protection, we strongly recommend To metallic
having separate earth connections enclosure
for the dialer and zone ground
terminals.

SPECTRA KEPADS
• The maximum number of keypads per installation is dependent on the
BELL OUTPUT auxiliary output, which is not to exceed 700mA.
Will shut down if current • Warning: Do not connect keypads more than 250ft (76m) from the control
exceeds 3A. panel.
• For the
keypad’s
zone, EOL and
tamper
configurations,
refer to
Configuring the
LED Keypads
on page 9.

AUX POWER
To connect additional wiring to auxiliary power, use the red A Door Contact or any other
(+) and black (-) keypad connectors. Auxiliary power will detection device can be
shut down if current exceeds 1.1A. If the auxiliary output is connected to the Keypad Zone.
overloaded and is shut down, you must disconnect all
loads from the output for at least 10 seconds before
reconnecting any load back to the auxiliary output.

For UL Listed warnings, refer to UL and ULC Warnings on page 51.

2.2 Earth Ground


Connect the zone and dialer ground terminals from the control panel to the metallic enclosure and cold water pipe or
grounding rod as per local electrical codes.
For maximum lightning protection, use separate earth grounds for the zone and dialer grounds as
shown in Figure 1 on page 2. For UL installations, the metallic enclosure must be grounded to the
cold water pipe.

Spectra Series 3