Section 14

Page: 1
Effective Date: October 1, 2021

SmartLine®
VersaFlow TWC 9400 Model Selection Guide
Coriolis Mass Flow Converter with Price Data
CM96 Modular I/O
Model Selection Guide Honeywell Proprietary
36-CM-16-50 Issue 8

Modular family of converters for all applications


Industry standard outputs including NAMUR
Common hardware for all housings
Higest Process Safety
Advanced diagnostics functions
Excellent long term stability
Easy to install and configure

Instructions
Select the desired key number. The arrow to the right marks the selection available.
Make the desired selections from Tables I through VIII using the column below the
proper arrow. A dot ( ) denotes availability.

List Price equals the sum of prices for all


selections made.

KEY NUMBER Description Selection Availability


CM96 Modular I/O Converter CM96

TABLE I
No Selection None 4 *

TABLE II
TWC 9400 C 4 *
TWC 9400 F H *
Type
Spare Converter Insert (Provide full model and serial number of original converter) S k
Spare Converter Insert (supplied configured w new labels if necessary, requires original serial number) T l

TABLE III
12 - 24 V DC ( 12 - 24 V DC ) 1 *
Power supply 24 V DC/AC ( 19 - 29 V ) 4 *
100 - 230 V AC ( 85-250 V AC, 50/60 Hz ) A *

TABLE IV
None - non Ex 0 *
ATEX Ex zone 1 (terminal compartment "d" - C, F) 1 f
Hazardous Area ATEX Ex zone 1 (terminal compartment "e" - C, F) 2 g
Approvals cFMus Class 1, Div 1 7 h
IEC Ex (terminal compartment "d" C,F) F f
IEC Ex (terminal compartment "e" C,F) G g

TABLE V
Default (See Note 1) 0_ *
3 x 1/2" NPT adaptors made of metal (mandatory for cFMus) 4_ *
Cable Connection 3 x PF 1/2" adaptors made of metal 5_ *
3 x M20 x 1,5 cable glands (standard: ATEX Ex de: metal). 6_ *
SS316 1/2" NPT adaptors(2x compact/4x remote) plus blanking plug R_ c
German Manual German Language _1 *
English Manual English Language _2 *
Operating Manual/
French Manual French Language _4 *
Language
Spanish Spanish Language _8 *
English Russian Operating language _S *

TABLE VI
Custody Transfer None 0_ *
Process Diagnostics Standard _ 0 *

TABLE VII
Without (for spare part electronics only) 0 *
Standard 1 *
Converter housing
St. st. 1.4404 ( for Compact ) 2 a
St. st. 1.4404 ( for Field ) 3 b

The minimum value of orders acceptable for Honeywell is USD 500. Handling fee is the amount of the difference between USD 500 and the actual purchase price.

Honeywell Process Solutions, 2101 CityWest Blvd., Houston, TX 77042


Printed in U.S.A. © Copyright 2021. Honeywell International Inc.
Section 14 Honeywell Proprietary
Page: 2
Effective Date: October 1, 2021

TABLE VIII Selection Availability


No Selection None V___ *
Module IO: CO act. + PO act./hc (CO-active+PO-active/high current) _4__ n
Module IO: CO act. + PO pas./hc (CO-active+PO-passive/high cur.) _6__ p
Module IO: CO act. + PO pas./Na (CO-active+PO-passive/Namur) _7__ q
Outputs Base Module Module IO: CO pas. + PO act./hc (CO-passive+PO-active/high cur.) _8__ r
Module IO: CO pas. + PO pas./hc (CO-passive+PO-passive/high cur.) _B__ s
Module IO: CO pas. + PO pas./Na (CO-passive+PO-passive/Namur) _C__ t
RS 485 MODBUS _G__ u
Without IO module __8_ *
Current Output - active __A_ *
Current Output - passive __B_ *
Outputs 1st I/O Module
Pulse Output - active / high current __C_ *
Pulse Output - passive / high current __E_ *
Pulse Output - passive / Namur __F_ *
Without IO module ___ 8 *
Current Output - active ___ A *
Current Output - passive ___ B *
Pulse Output - active / high current ___ C *
Outputs 2nd I/O Module Pulse Output - passive / high current ___ E *
Pulse Output - passive / Namur ___ F *
Control Input - active / high current ___ G *
Control Input - active / Namur ___ H *
Control Input - passive / high current ___ K *

TABLE IX
Standard (mass,density,temp.,vol.) 0__ *
Standard + Brix 1__ *
Standard + General concentration 2__ *
Standard + Baume 144.3 3__ *
Measuring Functions Standard + Baume 145 4__ *
Standard + NaOH 5__ *
Standard + Plato 6__ *
Standard + API oil standard A__ *
Standard + Alcohol B__ *
Standard on CD _0_ *
Manuals
Paper manuals _1_ *
None required __0 *
Remote Option Signal 5m/15ft __4 m
Cable is automatically selected as grey or blue
Cable 10m/30ft __1 m
depending on Ex or non Ex
20m/60ft __5 m

TABLE X
Destination Others 0 *

TABLE XI
Without (spare electronics) 0 *
VFC 100 1 *
VFC 200 2 *
VFC 6000 size 08-100 Extended Stem 6 *
Sensors
VFC 1000 7 *
VFC 6000 size 08 to 100 short stem A *
VFC 6000 Size 150 to 250 Extended Stem B *
VFC 6000 size 150 to 250 short stem C *

Note 1: For cable gland option "0" - Default:


For non Ex: 2x plastic M20 cable glands and 1 plastic blanking plug
For ATEX Ex d: 2 plastic transport plugs and 1 ATEX Ex d blanking plug made of metal
For ATEX Ex de: 2 metal M20 cable glands and 1 ATEX Ex d blanking plug made of metal

The minimum value of orders acceptable for Honeywell is USD 500. Handling fee is the amount of the difference between USD 500 and the actual purchase price.
Honeywell Proprietary Section 14
Page: 3
Effective Date: October 1, 2021
RESTRICTIONS
Restriction Available only with Not available with
Letter Table Selection Table Selection
a II 4
b II H
c IV 0
II 4, H, S
f
V 0_
II 4, H, S
g
V 0 _, 6 _
II 4, H, S
h
V 4_

V 0_
k
IX _00

V 0_
l
IX _00
m II H

_ _ 8 8, _ _ 8 C,
_ _ A 8, _ _ A A,
n VIII
_ _ A C, _ _ A G,
_ _ C C, _ _ C G

_ _ 8 8, _ _ 8 E,
_ _ A 8, _ _ A A,
p VIII
_ _ A E, _ _ A K,
_ _ E E, _ _ E K

_ _ 8 8, _ _ 8 F,
_ _ A 8, _ _ A A,
q VIII
_ _ A F, _ _ A H,
_ _ F F, _ _ F H,

_ _ 8 8, _ _ 8 C,
_ _ B 8, _ _ B B,
r VIII
_ _ B C, _ _ B G,
_ _ C C, _ _ C G

_ _ 8 8, _ _ 8 E,
_ _ B 8, _ _ B B,
s VIII
_ _ B E, _ _ B K,
_ _ E E, _ _ E K

_ _ 8 8, _ _ 8 F,
_ _ B 8, _ _ B B,
t VIII
_ _ B F, _ _ B H,
_ _ F F, _ _ F H

_ _ 8 8, _ _ A 8,
_ _ A A, _ _ A C,
u VIII
_ _ A K, _ _ C 8,
_ _ C C, _ _ C K

The minimum value of orders acceptable for Honeywell is USD 500. Handling fee is the amount of the difference between USD 500 and the actual purchase price.
Section 14 Honeywell Proprietary
Page: 4
Effective Date: October 1, 2021

Modular I/O (Table VIII) Modular I/O (Table VIII) Modbus (Table VIII)
Position Position Position
1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
4 8 8 6 8 8 7 8 8 8 8 8 B 8 8 C 8 8 G 8 8
C E F C E F A 8
A 8 A 8 A 8 B 8 B 8 B 8 A
A A A B B B C
C E F C E F K
G K H G K H C 8
C C E E F F C C E E F F C
G K H G K H K

The minimum value of orders acceptable for Honeywell is USD 500. Handling fee is the amount of the difference between USD 500 and the actual purchase price.