Technical Data Sheet

50VT
One component Unsaturated Polyesterimide UL approved
impregnating resin for open type HID ballast
January 2022

ELANTAS Beck India Ltd.


Marketing Head Office,
147, Mumbai Pune road,
Pimpri,
Pune 411018
India
Tel +91 20 67190 600
Fax +91 20 67190 792
www.elantas.com/beck-india

50VT Page 1 of 4 Rev 4, May 2019


Description under vacuum or by the vacuum pressure
50VT is an electrical insulating method is advisable because of the special
impregnating resin provided with a special filler structure. Losses of Vinyl Tolune,
filler structure consisting of a premixed which occur as a result of vacuum
resin and hardener component. It is noted impregnation, should be replaced from
for its good compatibility with punching time to time to ensure a uniform viscosity.
grease and very good hiding power, e.g. With a resin throughput of > 12% per
on choke housings. An unsaturated week, 50VTcan be processed practically
polyesterimide is used as base resin, without restriction at 250C. Since the
which displays very good thermal load activated resin is a highly reactive system,
capacities in the cured state. Since base the temperature of the resin in the storage
resins are frequently solid or very highly or mixing containers of the impregnating
viscous, they are dissolved in a reactive plant should not exceed 250C. Before the
monomer. In this case VinylTolune is used beginning of relatively long rest periods it is
as reactive monomer, which reacts on advantageous to cool down the resin in the
account of its reactive double linkage with impregnating plant to 10-200C. The resin is
the resultant cured material. propertiesThe to be protected from light during
material does not contain by recipe processing and storage
substances listed in Restriction of
Hazardous Substances (RoHS) Directive Recommended Storage
(2002/95/EC) The resin should be stored at a
Areas of Application temperature not exceeding 25°C in original
50 VT is preferably used for impregnation sealed container. At this temperature, the
of static device such as transformers, resins will remain good for 3 to 6 months.
chokes etc. At higher storage temperature, the storage
life would decrease sharply. The resin and
hardener container should not be exposed
Properties of cured material to sunlight to avoid premature gelation.
50VT gives natural glossy finish cured During storage in godown or in the tank if
film. The cured film is tough hard material reduction in gel time is observed then
with good mechanical and dielectric required quantity of Inhibitor UP1 should
properties. 50VT gives necessary strength be incorporated in the activated resin. For
to coils and stacks of sheets. By virtue of further details refer technical data sheet of
the special structure of the filler, very good Inhibitor UP1
heat dissipation from the impregnated
winding is achieved. In addition, the cured
material displays good resistance to
solvents and their vapours, oil and other
chemicals. Due to the high temperature
index of 180, 50VTcan be used for
components of thermal class H (1800C).
The good thermal load capacity ensures
reliable operation of the ballast.
Application Method
50VT can be processed in all conventional
impregnating resin plants, for example by
dipping / flooding / VPI etc. Processing
50VT Page 2 of 4 Rev 4, May 2019
Properties of 50VT as supplied
Colour & appearance [*] DBI 1001[**] Pale yellow to
brown hazy liquid
Viscosity at 25°C[*] DBI 1015A S 50 -75 [+]
IS 3944 Cup No. 4
Density at 23oC DBI 3047A [**] g/ml 1.10 -1.20
Recommended Diluent Diluent V
DBI 1005 [**] (closed cup) oC 51
Flash point
Storage stability [*] When stored in original sealed months 6
0
container at 25 C or below
[*] These properties form our sales specification
[**] DBI are internal test methods and are available on request.
[+] Viscosity and Gel time values are likely to change during the shelf life period.

Mixing Proportions & Pot life

Mixing proportion Single component resin pbw N.A

Gelling & recommended Curing Cycle :


Gelling time at 125oC [*] DBI 3156 [**] min 5 - 15
2 hour at 150oC
The suggested curing time is after the unit attains specified temperature. Depending upon
the size and weight of the unit, heating time is required to be added.
Cured Film Properties :
Curing in thick layer DBI 3007 [**] Top S1: Smooth
10g/140°C/2h Bottom U1: non-tacky
Inside I1.1:Tough, No bubble
at RT 200N
Bond Strength IEC 61033
At 155oC 40 N

Temperature Index as per UL 1446 (File # E253938) NEMA MW 1000 - 30C :


By Proof voltage, twisted pair 1000 V o
180
C
By Bond strength, Helical coil 22 N 200

50VT Page 3 of 4 Rev 4, May 2019


o
Dielectric Properties Specimen Curing - 2 h at 150 C
at RT 80
Dielectric strength as per o
at 155 C kV/mm NT
IEC 60455-2
after 24 h water immersion at RT 50
15
Volume resistivity at 500 V at RT 10
ohm.cm 13
DC as per IEC 60455-2 after 168 h water immersion at R.T. 10
Dielectric constant at 30 V/1 at RT
0 - NA
kHz as per IEC 60455-2 at 155 C
Dielectric loss factor 30 V/1 at RT
0 - NA
kHz as per IEC 60455-2 at 155 C

Resistance against solvents & chemicals


Solvent resistance as per IEC 60455-2 10% H2SO4 - No Change in colour
2% NaOH - No Change in colour
Water absorption as per ISO 62 24h at 25°C % 0.105

Packaging
50VT : 210Kg in EP lined MS Disclaimer

Containers This information is intended only for


Diluent V : 1 & 4 kg in polythene general guidance in the application of our
container & 21 kg in EP lined drums product. It has been obtained by careful
investigation and represents the present
Safe Handling state of our knowledge and experience.
Because of the large number of possible
50VTis a flammable liquid. Use foam, CO2 methods of application and processing we
or dry chemical powder for fire fighting. are not able to assume responsibility in
Inhalation and direct contact with the skin any one particular case for either the
should be avoided. In case of contact, the technical results or the patent rights
affected area should be washed with soap situation applicable to the country under
and plenty of water. For further details ask consideration
for our material safety data sheet.
Technical Services Department Regional Offices:
147, Mumbai-Pune Road, • Bengaluru: Tel: (080) 6792 0871, 6792 0872
Pimpri, • New Delhi: Tel: (011) 2341 1664, 2341 2940
Pune 411018 Fax: 2341 3408
India • Pune: Tel: (020) 67190 673
Tel +91 20 67190 720/722 Fax: 67190 792
Fax +91 20 67190 792 • Kolkata: : Ph:033-44000500

50VT Page 4 of 4 Rev 4, May 2019