Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PLOT LIMIT

FOR SITE USE


LEGENDS
SYMBOL DESCRIPTION
OPEN SPACE Mirror Light

Lift Shaft Light

Wall mounted Exhaust Fan

Bell Chime

EXISTING UPSTAND KERBSTONE


Bell Push Button

1Way Switches (1G,2G&3G)

2Way Switches (1G,2G&3G)

13A Switch Socket Outlet - Single

13A Switch Socket Outlet - Twin

WATER TANK
13A Switch Socket Outlet - Single (W/P)

GREEN

GREEN
20A Socket Outlet for Water Heater

DRIVEWAY LVL.
20A DP Switch Outlet with Neon Indicator

19
For Water Heater

+0.70
18

20A Socket Outlet for Washing Machine with


20A DP Switch Outlet
SPN Isolator (Rating as Indicated)

EXISTING DROP KERBSTONE


TPN Isolator (Rating as Indicated)

HAVE SOLAR REFLECTANCE INDEX (SRI)


BICYCLE PARKING 3.5 % SLOP RJ45 Socket

50% OF THE PAVING SPACE'S SHOULD


DMD GATE LVL. +31.62

INT. LVL.

INT. LVL.
+0.65

+0.60
GD GAS Detector
PROPOSED GATE LVL. +0.30

20
17

12u 12U Cabinet

VALUE OF 29 OR ABOVE
ATTIC SLAB Distribution Board

LW01
AD-03
Sub Main Distribution Board

W05

AD-04
INT. LVL.
+0.85
Addressable Fire Alarm Manual Call Point

Addressable Fire Alarm Sounder


PLOT

AD-01
Addressable Fire Alarm Sounder Flasher
16

21
Fire Tel. Jack

ALD-01

PUMP R.

TRANSFORMER
Fire Alarm Speaker

AREA :32.33 SQ/M


ELEC.
W.M

S.S.L & F.F.L

S.S.L & F.F.L


+0.75
F.F.LVL.
MM Addressable Monitor Module

+0.75

+0.45
Notes:-

ALD-02
CM Addressable Control Module
* All Dimensions are in mm, Otherwise Indicated

PROPOSED UPSTAND KERBSTONE


Wall mounted Emergency Exit Light
REVISION:
DRIVEWAY LVL.

Wall mounted Em. Self Contained Light

PROPOSED GATE LVL. +0.35


22
03
15

+0.70

Wall mounted Em. Self Contained Exit Light 02

GARB. R.
01

+0.95
F.F.LVL.
Stair / External CCTV Camera 00 07.11.2022 ISSUED FOR SITE
NO. DATE REVISED STATUS

DMD GATE LVL. +31.67

M
CONSULTANT'S TABLE

ENTRANCE
Approved As Submitted

LOBBY
A

GR.F.LVL.
LIFT LOBBY

GR.F.LVL.
+0.65

+0.65
23

B Approved As Noted
14

GR.F.LVL.
+0.65
Revise and Resubmit

GF-02
C
D Rejected
SPEED HUMP SPEED HUMP

Signature: Date:

GAS PIPES

ROAD
PROJECT

09

08

07

06

05

04

03

02
10

01
SLOP : 8.2 %

F.F.C
PROPOSED G+4+R
24

CU-GF 01

GR.F.LVL.
+0.50
RESIDENTIAL BUILDING
13

30 STEPS X 15.83cm

CLIENT

GR.F.LVL.
+0.50
SLOP : 3.5 %

SD-01
INT. LVL.
AZIZ ALI MOHAMMAD HASAN

20
+0.65

12

13

14

15

16

17

18

19
11
AL MARZOOQI

Gate barrier
HAVE SOLAR REFLECTANCE INDEX (SRI)

CM
50% OF THE PAVING SPACE'S SHOULD

SPEED HUMP

RCC

PROPOSED GATE LVL. +0.30


HAVE SOLAR REFLECTANCE INDEX (SRI)
CONSULTANT

50% OF THE PAVING SPACE'S SHOULD


12

ENTRY/EXIT
VALUE OF 29 OR ABOVE

DRIVEWAY LVL.

DMD GATE LVL. +31.62


VALUE OF 29 OR ABOVE
+0.60

SLOP 2 %
DRIVEWAY LVL.
MAIN CONTRACTOR
+0.70
SPEED HUMP
PLOT

11

AUTO-BUILD CONT.
COMPANY
PROPOSED DROP KERBSTONE
MEP CONTRACTOR

CM
TEL.
+1.00
F.F.LVL.
AD-02

DRAWING TITLE

GROUND FLOOR PLAN


10

03
09

08

07

06

05

04

02

01
LEC. & LCS POINTS ON
CORE WALL & COLUMNS
INT. LVL.
+0.85

CAD BY : Abdul Gafoor SIGN:

CHECKED BY : Eng. SWEED SIGN:

DATE: 07 Nov 2022 SCALE: NTS@A2

EMIRATES LOCATION PLOT NO.


WADI AL SAFA 2ND,
DUBAI DUBAI 6430288

PROJECT NO. DWG. REF.NO. REV.

C215101 AAQ/SD/GF/WCO-01A 01

T LIMIT
OPEN SPACE Dwg. Ref G:\Abdul Gafoor System Files\2022\1) Job In Hand\5) G+4+R (Cubic)\
3) Shop Drawings\13. For Site\WCO\ WCO-01 Ground Floor