Professional Documents
Culture Documents
Combined Footing Type5
Combined Footing Type5
P1 P2
Dimensions: M1 M2
Col 1 Col 2 fy
Length, x (m) 0.40 0.45
Width, y (m) 0.40 0.45 d
Material Properties:
Concrete strength, f'c (Mpa) 20.0 Xb Xp Xa
Tensile strength, fy (Mpa) 276
Allow soil pressure, qa (kPa) 240.0 L
Loads
Service Loads
Col Loads DL LL Wind Eq Assume weight of footing as 10% of column loads
P1(kN) 935.0 625.0 0.0 0.0
P2(kN) 1070.0 715.0 0.0 0.0
M1(kN-m) 0.0 0.0 0.0 0.0
M2(kN-m) 0.0 0.0 0.0 0.0
Factored Loads
Load Case 1 2 3 4
P1(kN) 2371.50 841.50 1778.63 1778.63 Case 1: 1.4DL + !.7LL
P2(kN) 2713.50 963.00 2035.13 2035.13 Case 2: 0.9DL + 1.3WL
M1(kN-m) 0.00 0.00 0.00 0.00 Case 3: 0.75(1.4DL + 1.7LL + 1.7WL)
M2(kN-m) 0.00 0.00 0.00 0.00 Case 4: 0.75(1.4DL + 1.7LL + 1.87EQ)
Check User Input Footing Dimensions Uniform upward pressure, qu (kN/m) 758.96
Allowable. Soil Pressure, qa (kPa) 240.00
Maximum. Soil Pressure, qmax (kPa)
Minimum. Soil Pressure, qmin (kPa)
Area of Steel
Steel Diameter (mm) 36 for top reinforcement, As(mm2) 1017.88
Steel Diameter (mm) 36 for bot reinforcement, As(mm )
2
1017.88
Details
S= 93.49
S= 366.14 S= 366.14