2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
8248 9752 9000 9000 9000 9000 9000 9000 9000 10400 7600
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 A6 TROLLEY PATH
TROLLEY PATH
A5
A4 TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
DRAIN
Ø40 CDR Ø40 CDR
Ø90 CDR A3 TROLLEY PATH
A6 EL +4.700 EL +4.560
A6 A2 TROLLEY PATH
EXISTING ATRIUM
OMAN TEL
L016
L030
BR-02 ELE
L002 BR-03 L031
L003 DH DRIVER
DRAIN
323
TROLLEY PATH TOI.
A1 000
TROLLEY PATH
BOILER ROOM
UP
BR-04
99
L004
HD OFFICE
IKEA DRY STORE BR-06 HOME DELIVERY S.LIFT-03 (5 TON) 600b
278 L006 600b 590f
TROLLEY PATH
B2 S.LIFT-01 (2 TON)
SANITATION
F.T
PASSAGE
RECEIVING F.T
262 UP
481
281
Ø90 CDR
F.T
BR-05
CHILLER/WALK IN
F.T
C C
E
ENTRANCE
OIL ROOM
GENTS TOI.1443 490
GARBAGE ROOM
480 WATER TANK
REF.
270
261
FREEZER
E
1445 L014
B3 272
260b
AIRLOCK REC/SECURITY/
TROLLEY PATH
L008
SERVER ROOM CCTV
IT ROOM 420
422
11a
SLOPE - 1:10
WALL
GREASE
TRAP
ROOM
1:15
B4
TROLLEY PATH
1:10
RAMP UP TO GROUND
A5 A5
EXIT-03
RAMP UP TO GROUND 1:10
B5 LOBBY
L010
GENERATOR
1000KVA
IKEA
S.LIFT-06 (5 TON)
590i
DRAIN
SEC. RM 1 (MALL)
B6 L010
+44.300 FFL
UP 4800
SUBSTATION
L025
UP
+44.000 FFL
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
L023
L024
B8
STAIR
790a
Ø90 CDR
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
TROLLEY PATH
B10 STORE
L027
A4 A4 B11
DRAIN
250 KVA
WALL
N GENERATOR
DRAI MALL
B12
1:61
B13 DRAIN
DRAIN
AIN
DR
B14
Ø90 CDR
DRAIN
DRAIN
1295
KEY PLAN
SLOPE 1:150
A3 A3
Ø90 CDR
NOTE:
EL +3.000
Ø90 CDR
2. ALL IL (INVERTED LEVEL) ARE FROM INSIDE BLDG FFL.
A2 A2
Ø90 CDR
FCU-ML-LG-01 Ø25 CDR
OMAN TEL
BOU +3.800
WITH 'P' TRAP
EL +3.700 LEGEND
L030 1295
EXISTING ATRIUM
Ø25 CDR
SP SOIL PIPE
SLOPE 1:150
L016
WITH 'P' TRAP
EL +2.900 BR-02 Ø25 CDR
Ø50 CDR DROPS INL002
WALL WITH 'P' TRAP
CONNECTED TO NEAREST STORM WATER EL +3.700
WP WASTE PIPE
Ø25 CDR
ELE
L031
Ø32 CDR PROVISION Ø32 CDR PROVISION
BR-03
L003
FCU-IK-LG-01 K_WP KITCHEN WASTE PIPE
AHU-ML-LG-02 BOU +3.800 1925
3055
F_WP FISH WASTE PIPE
DRAIN
BOU +3.050 Ø32 CDR PROVISION 610 DH DRIVER
323
Ø50 CDR Ø50 CDR Ø90 CDR
1080 EL +3.740
Ø50 CDR SLOPE 1:150 Ø50 CDR
3040
TOI.
Ø50 CDR Ø50 CDR
EL +3.390 EL +2.870
VP VENT PIPE
Ø90 CDR
A1 Ø40 CDR
EL +3.890 Ø50 CDR
EL +3.755 2925
820 820 Ø90 CDR
EL +3.620
Ø90 CDR
EL +3.600
Ø90 CDR
EL +3.560 Ø90 CDR
EL +2.860 A1 CDR CONDENSATE DRAIN
EL +2.845
Ø40 CDR
FCU-IK-LG-02A
4630
Ø32 CDR PROVISION
Ø90 CDR
BOU +3.600
MH MANHOLE
SHAFT
P.LIFT-01 Ø50 CDR Ø25 CDR
MEP
EL +4.700 Ø50 CDR WITH 'P' TRAP
1455 Ø63 CDR EL01
EL +4.490 EL +3.500 FCU-IK-LG-02B
Ø63 CDR EL +4.000 Ø63 CDR SLOPE 1:150 Ø63 CDR 1150
Ø50 CDR F/A
Ø63 CDR F/A
EL +4.050 Ø63 CDR Ø90 CDR BR-01
KIOSK-01
3980
Ø50 CDR Ø50 CDR
Ø25 CDR RECYCLING PLANT
BOU +3.600
Ø25 CDR
GT GULLY TRAP
EL +3.825 EL +3.850 Ø25 CDR WITH 'P' TRAP
L001
P.LIFT-02
Ø90 CDR
EL +2.800
WITH 'P' TRAP
EL +3.500
EL +3.500
160 FG FLOOR GULLY
FCO FLOOR CLEAN-OUT
5785
EL01 FCU-IK-LG-02C Ø25 CDR
Ø32 CDR PROVISION BOU +3.600
Ø50 CDR
2145
CORRIDOR
EL +3.335
Ø50 CDR
Ø50 CDR
EL +3.390
1225
AD AREA DRAIN
Ø50 CDR Ø25 CDR
Ø50 CDR
B1 995
L007
Ø90 CDR 1225
EL +3.350 EL +3.840 Ø25 CDR EL +3.415
B1 T/A TO ABOVE
SLOPE 1:150
EL +2.770
FCU-IK-LG-03A
1205 EL +3.855
BOU +4.000
T/B TO BELOW
Ø32 CDR
F/A FROM ABOVE
Ø25 CDR
UP WITH 'P' TRAP BOILER
EL +3.900 ROOM
Ø90 CDR
Ø25 CDR
Ø90 CDR
OVERFLOW PIPE
F/B FROM BELOW
Ø90 CDR
Ø32 CDR PROVISION
FCU-IK-LG-06
EL +3.700
BR-04
FCU-IK-LG-05A
BOU +4.075 Ø25 CDR
WITH 'P' TRAP
2145
FCU-IK-LG-03B
MV
Ø90 CDR
TANK INTERCONNECTION EL ELEVATION (BOTTOM OF PIPE ) OF PIPE FROM F.F.L
BOU +3.800 L004 BOU +4.000
Ø50 CDR F/A EL +3.700 Ø90 CDR MV
Ø50 CDR F/A Ø50 CDR F/A BR-06 EL +3.565 FCU-IK-LG-05B Ø25 CDR EL + 2.700
IKEA DRY STORE
Ø25 CDR PROVISION 905 HD OFFICE MV
L006 685 BOU +4.075 EL +3.890 WITH 'P' TRAP Ø50 CDR 600b Ø50 CDR
278
EL +3.700 EL +3.900 MV
Ø90 CDR Ø90 CDR Ø90 CDR
Ø25 CDR
2285
Ø25 CDR Ø50 CDR OVERFLOW PIPE
Ø25 CDR Ø50 CDR Ø25 CDR
WITH 'P' TRAP FCU-IK-LG-04
COMMENTS
1570
1560
470 EL +3.660 EL +3.565
865 EL +3.700 985 EL +3.635 Ø90 CDR WITH 'P' TRAP
Ø25 CDR BOU +3.800 Ø25 CDR
B2 4050 2820 855 855
EL +3.665
WITH 'P' TRAP 1870
EL +3.065
WITH 'P' TRAP
EL +3.900
B2 COORDINATE WITH HVAC & CIVIL DRAWINGS. LOCATION OF HVAC EQUIPMENTS SHALL BE
1770 1215
Ø50 CDR Ø50 CDR Ø32 CDR EL +3.900 EL +3.700
SLOPE 1:150
855
S.LIFT-01 Ø50 CDR
EL +3.715
F.T
EL +3.690 EL +3.545
FCU-IK-LG-10B
3955
AS PER APPROVED HVAC DRAWINGS
LOBBY
STAIRCASE
262
3100 S.LIFT-03
Ø90 CDR
SANITATION BOD +3.800 590f
S.LIFT-02 Ø50 CDR F/A
HOME DELIVERY 590c FCU-ML-LG-02A
Ø50 CDR
EL +4.400
263
490
PUMP ROOM &
Ø25 CDR 600b
BOU +3.800 WATER TANK
IL & FINAL ROUTING OF THE PIPES SHALL BE AS PER APPROVED COORDINATION DRAWINGS
F.T
EL +3.505
Ø50 CDR
EL +3.570
THIS DRAWING APPROVAL IS ONLY FOR PREPARATION OF THE COORDINATION DRAWINGS.
2620
Ø25 CDR
F.T
2995
WITH 'P' TRAP Ø25 CDR Ø50 CDR Ø50 CDR
SLOPE 1:150
WITH 'P' TRAP THE CONTRACTOR SHALL RESUBMIT THIS DRAWING IF REQUIRED BASED ON THE
F.T
EL +3.700 WITH 'P' TRAP
SLOPE 1:150
EL +3.700 1055
2985
C C
CO-WORKER EL +3.700 Ø90 CDR Ø50 CDR
EL +3.625 465
APPROVED COORDINATION DRAWINGS OR ANY KIND OF MAJOR CHANGES IN THE ARCH
E
ENTRANCE 2180
Ø25 CDR 480 EL +3.115 EL +3.470 Ø25 CDR
WITH 'P' TRAP FCU-IK-LG-14A WITH 'P' TRAP
ROOM 260b
BR-05
5285
GARBAGE
GREASE
FCU-IK-LG-14B
4930
EL +3.700 CHILLER/ BOU +3.800 TRAP ROOM Ø25 CDR EL +3.700
OIL ROOM
L005
FREEZER E WALK IN
REF.
BOU +3.800
EL +3.550
975 WITH 'P' TRAP
EL +3.700 LAYOUTS
261
272
STAIR 830 Ø50 CDR Ø25 CDR 2325 EL +3.550 855
Ø50 CDR FCU-ML-LG-03C FCU-ML-LG-02B
SLOPE 1:150
790
Ø25 CDR FCU-IK-LG-12B BOU +3.800 BOU +3.800 REFER COMMENTS IN THE PART PLANS
B3 EL +3.540
B3
SLOPE 1:150
AIRLOCK EL +3.800 BOU +3.800 Ø50 CDR 755
1445
EL +3.590 FCU-IK-LG-13
1735
L008 LADIES
Ø25 CDR
TOI.
Ø50 CDR
GENTS TOI.
3470
WITH 'P' TRAP
Ø90 CDR
EL +3.660 EL +3.590 ROOM ELE. ROOM BOU +3.800
2145 Ø25 CDR 422
REC/SECURITY/CCTV
(MALL)-02 EL +3.700
735 420
5415
Ø40 CDR F/A FCU-IK-LG-10A EL +3.585 WITH 'P' TRAP Ø25 CDR
WITH 'P' TRAP Ø50 CDR
BOD +3.800 IT ROOM EL +3.700
EL +3.570 EL +3.700 SLOPE 1:150
665 Ø50 CDR
Ø40 CDR EL +3.565 FCU-IK-LG-12A
Ø90 CDR
Ø25 CDR 685 FCU-IK-LG-11
Ø50 CDR
CONNECTED TO FG BOD +3.800 735
WITH 'P' TRAP BOU +4.140 855
WALL
Ø50 CDR Ø90 CDR SUBSTATION-02
WITH 'P' TRAP SLOPE 1:150 EL +3.700 EL +3.195
CO Ø90 CDR Ø90 CDR SLOPE 1:150 Ø90 CDR Ø90 CDR EL +4.000 SLOPE 1:150 Ø90 CDR Ø90 CDR
Ø50 CDR
REVIEW STATUS
Ø90 CDR Ø90 CDR Ø90 CDR Ø90 CDR Ø90 CDR Ø90 CDR Ø90 CDR EL +3.435
EL +3.615 EL +3.545 EL +3.470 EL +3.430 EL +3.420 EL +3.340 EL +3.250
1660 Ø25 CDR
Ø50 CDR
Ø50 CDR
EL +3.420 EL +3.585
Ø50 CDR Ø25 CDR
SLOPE 1:150
5740
5740
5740
5740
CO
Ø63 CDR
Ø25 CDR Ø25 CDR
Ø90 CDR
3005
3005
WITH 'P' TRAP WITH 'P' TRAP
EL +3.215
EL +3.650 EL +3.650
3330
B4 AHU-ML-LG-01C
BOU +3.750
AHU-ML-LG-01D
BOU +3.750 B4 CODE A – APPROVED
2020
Ø63 CDR F/A (FROM GROUND FLOOR)
EL +4.000
1:11 2105
SLOPE 1:150
Ø50 CDR
CODE C – REVISE & RESUBMIT
1:11
CODE D – REJECTED
B5 B5
2235
2235
FCU-IK-LG-15 NOTE – THE SUBMITTAL WAS REVIEWED FOR DESIGN CONFORMITY AND GENERAL CONFORMANCE TO CONTRACT
LOBBY BOU +3.900 EL +3.595
L010 Ø25 CDR Ø25 CDR Ø25 CDR DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS AT JOB
Ø25 CDR
3330
SITE FOR TOLERANCE. CLEARANCE, QUANTITIES, FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION
WITH 'P' TRAP
EL +3.800 COORDINATION OF HIS WORK WITH OTHER TRADES AND FULL COMPLIANCE WITH CONTRACT DOCUMENTS. APPROVAL
DOES NOT RELIEVE THE CONTRACTOR OF ANY OF HIS OBLIGATIONS AND RESPONSIBILITIES UNDER HIS CONTRACT.
S.LIFT-06
590i
Ø25 CDR
TRANSMITTAL/LETTER REFERENCE:
DRAIN
SEC. RM 1 REVIEWED BY: JVK DATE, TIME: 14 Mar 2021 12:21
(MALL)
B6 B6
L010
UP
AHU-ML-LG-1A
BOU +3.375 CO
Ø50 CDR
EL +3.310
SHOP DRAWING
Ø50 CDR
3330
Ø25 CDR SUBSTATION
SLOPE 1:150
WITH 'P' TRAP
EL +3.375
L025
Ø25 CDR
MT MAIN ELE
4160
Ø25 CDR
UP ROOM
527 WITH 'P' TRAP
EL +3.375
FCU-IK-LG-16 Ø50 CDR
BOU +3900 EL +3.275
AHU-ML-LG-1B
Date
Ø50 CDR
Ø25 CDR
WITH 'P' TRAP
BOU +3.375
Rev. Description Signature
B7 EL +3.800
Ø50 CDR
B7
Ø50 CDR
EL +3.250
Ø50 CDR
Ø50 CDR
CONNECTED TO RWP EL +3.585 352-(&7
EL +3.220
Ø50 CDR
(MALL)
SLOPE 1:150
AHU-ML-LG-3A L024
BOU +3.865
AVENUES MALL
SEC. ROOM
(MALL)
L023 3810
Ø25 CDR
WITH 'P' TRAP Ø50 CDR
STAIR 790a
EL +3.765 CO EL +3.650
&/,(17
B8 B8
352-(&70$1*(5
B9 B9
&2168/7$17
B10 B10
Ø40 CDR F/A
3030
3030
FG-1
940
Ø40 CDR
CONNECTED TO FG-1
0$,1&2175$&725
B11 B11
ELECTRO MECHANICS
68%&2175$&725
DRAIN
WALL
IN P.O.BOX 1413 POSTAL CODE 112 ,RUWI
DRA
SULTANATE OF OMAN .
'5$:,1*7,7/(
MAJOR TENANT
LOWER GROUND FLOOR CONDENSATE
DRAIN OVERALL LAYOUT
B13 IN B13
DRA Drawn by : SS Date
B14 N
DRAI B14 Scale: Job No. 2006 Location : BAUSHAR
2 3 4 5 6 7 8 9 10 11 12 13 14
DRAIN
15 16 17 18 19 20 21 22 23 24 25 26 27 28 EM-2006-MEP-EOM-MT-SD-PLB-104 1 1