GENERAL REPAIR WORKS AT PUBLIC PROSECUTION

SITE DEVELOPMENT PLAN: (DWG. NO.: AR-01)


GENERAL REPAIR WORKS AND PREPRATION:
A09: INSPECT THE BUILDING ON CIVIL EXISTING WORKS CONDITION, PREPARE AND
SUBMIT DETAILED REPORT.
A10: CONTRACTOR TO PROVIDE TEMPORARY WOODEN STORE AND PORTACABIN OFFICE
AT AREA MENTIONED ON THE SITE PLAN.
GENERAL STRUCTURAL CONCRETE REPAIR WORKS.
CAR PARKING SHADES:
M27: REPLACE THE EXISTING CAR PARKING SHADE WITH PVC COATED FABRIC PARKING
SHADES.
E55: PROVIDE BOLLARD BARRIERS COMPLETE WITH FOUNDATION, INCLUDING CHAIN
LINK.
E57: CARRY OUT THE REQUIRED REPAIRING WORKS TO THE EXISTING CAR PARKING
SHADE ELEMENTS.
G92: PROVIDE POSITIONS PLATES FOR CAR PARKING SHADE USERS.
EXTERNAL WORKS:
E03: REPLACE DAMAGED INTERLOCK BRICKS.
E07: CAREFULLY TAKE OUT THE INTERLOCK BRICKS, FILL THE GAP WITH CRUSHER FINE,
COMPACT AND RE-FIX THE BRICKS.
E22: REPLACE DAMAGED ASPHALT PAVING.
E36: REPAIR THE ENTRANCE GATES BY REPLACING THE DAMAGED ELEMENTS.
GENERAL WORKS TO ALL FLOORS:
J45 AND J46: REPAIR THE ALUMINUM WINDOW SHUTTERS.
J48: REPLACE DAMAGED ALUMINUM WINDOW FLY SCREEN.
J50: REPLACE DAMAGED WINDOW HANDLE.
N22: CLEAN THE DUSTY CEILING TILES AT A.C GRILLS AREA.
P03A: REPLACE THE ELECTRICAL FLOOR BOX TILES.

SITE DEVELOPMENT PLAN: (DWG. NO.: AR-02)


GENERAL WORKS TO ALL FLOORS:
G36 AND G38: REPAIR SINGLE DOOR FRAME AND SHUTTER BY MINOR PATCH UP.
G81A: SUPPLY AND FIX OVERHEAD DOOR CLOSER.
G94: SUPPLY & INSTALL OF 400 MM X 800 MM POLYCARBONATE SHEET BEHIND STAFF
CHAIR.
G95: SUPPLY OF D.B BOXES MADE OUT OF GALVANIZED STEEL PANEL.
GENERAL REQUIREMENTS: To be provided by the contractor: O15-O21.
FLAT WATER PROOFING:
M25A AND M25: HACK OFF EXISTING WATERPROOFING TREATMENT AND SUPPLY AND FIX
NEW MEMBRANE WATERPROOFING SYSTEM.
DRAINAGE WORKS AND CLEANING.

SITE DEVELOPMENT PLAN: (DWG. NO.: AR-03)


GENERAL PAINTING WORKS:
T04: CLEAN THE EXTERNAL WALL SURFACE WITH SWEET WATER.
T16: CLEAN THE CAR PARKING SHADE METAL ELEMENTS BY USING SPRAY WATER.
U01 AND U03: PROVIDE PAINT TREATMENT TO NEW SURFACES.
EXTERNAL & INTERNAL PAINTING WORKS:
V01: PREPARE THE SURFACE AND APPLY ONE COAT OF EMULSION PAINT TO INTERNAL
CEILING SURFACES
V05: PREPARE THE SURFACE AND APPLY TWO COATS OF EMULSION PAINT TO INTERNAL
WALL SURFACES INCLUDING CORRIDORS& STAIRWAYS
W06: PREPARE THE SURFACE AND APPLY TWO COATS OF GLOSS PAINT TO INTERNAL
WALL SURFACES INCLUDING CORRIDORS & STAIRWAYS.
V13: PREPARE THE METAL SURFACE ELEMENTS AND APPLY APPROVED ONE COAT OF
PRIMIER & TWO COATS OF METAL SPRAY ANTI RUST PAINT TO STEEL SURFACES.
GENERAL TOILETS CLEANING:
H16: REPLACE DAMAGED 6MM THICK TOILET MIRROR.
S: CLEANING AND WASHING OF WATER CLOSET, WASH HAND BASIN AND TOILETS FLOOR
TRAP.

CAR PARKING LAYOUT: (DWG. NO.: AR-04)


GROUND FLOOR PLAN: (DWG. NO.: AR-05)
DISMANTLE AND INSTAL WORKS TO LOCATIONS 1,2:
C19: REMOVE EXISTING INFORMATION DESK, THE CUSTOMER AND CASHIERS COUNTERS
DESKS AND SECURITY DESKS WORKS FROM THE ALOCATION WORKING AREAS, AND TO
BE DELIVERED TO BMD STORE.
C20: SUPPLY & INSTALL 5500 X 2500 MM NEW INFORMATION (RECEPTION) COUNTER DESK
FOR 4 NOS OF STAFF MADE OUT OF WOODEN VENEERS.
C21: SUPPLY (5500 MM LENGTH X 3000 MM HEIGHT) FIXED DECORATION WOODEN PANEL
IN STRIPS DESIGN WITH CLIENT LOGO.
NEW CUSTOMER SERVICE AND CASHIERS DESKS WORKS:
C25: SUPPLY & INSTALL 8500 LM OF NEW CUSTOMER'S, AND CASHIERS COUNTERS DESKS
FOR 6 NOS OF STAFF.
C26: SUPPLY AND FIX 100 THICK OF GYPSUM PARTITION WITH NORMAL WASHABLE PAINT
BETWEEN THE NEW CUSTOMER'S COUNTER DESK AND CASHIER COUNTER DESKS.
C27: SUPPLY AND INSTALL NEW CREDENZA OF 500MM DEPTH X 800 MM HEIGHT.
C28: SUPPLY (9300 MM LENGTH X 3000 MM HEIGHT) AND FIXED DECORATION WOODEN
PANEL DESIGN.
C29: SUPPLY (9300 MM LENGTH X 2500 MM HEIGHT) AND FIXED DECORATION WOODEN
PANEL IN STRIP DESIGN.
RENOVATION WORK TO LOCATION NO. 3:
C12 and C13: REMOVE THE EXISTING WINDOW AND THE EXISTING DOOR SHUTTER
INCLUDING FRAME.
C14: DEMOLISH THE EXISTING PARTITION TO INCREASE THE STORE SIZE.
C28: SUPPLY (9300 MM LENGTH X 3000 MM HEIGHT) AND FIXED DECORATION WOODEN
PANEL DESIGN.
F32: SUPPLY AND FIX NEW GYPSUM BOARD PARTITION.
F33: PROVIDE DOOR OPENING INTO NEW GYPSUM BOARD PARTITION.
F34: PROVIDE WINDOW OPENING GYPSUM BOARD PARTITION
G96: REPAIRE THE EXISTING DOOR FRAMES AND APPLY NEW SPRAY FINISH.
G110: SUPPLY & FIX NEW WOODEN SINGLE DOOR SHUTTER.

GROUND FLOOR PLAN: (DWG. NO.: AR-06)


AUTOMATIC SLIDING DOORS:
J64: REMOVE THE EXISTING GLASS DOOR AT PRIVATE ENTRANCE, SUPPLY & INSTALL +
2000 LM AND + 2800 HEIGHT OF NEW AUTOMATIC SLIDING DOOR WITH CARDS READERS
FROM BOTH SIDES (IN / OUT).
O23: SUPPLY AND FIX 2 NO. S OF PUBLIC PROSECUTION LOGO ON MAIN ENTRANCE
GLASS DOORS.
EXTERNAL GYPSUM BOARED CEILING:
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
F31 AND J14: REPLACE WINDOW INTO EMERGENCY DOOR.
K17 AND S08: KITCHEN CLEANING.
2 NOS. ENTRANCE DOUBLE DOORS:
G96: REPAIRE THE EXISTING DOOR FRAMES AND APPLY NEW SPRAY FINISH.
G97: SUPPLY & FIX NEW WOODEN DOUBLE DOORS SHUTTER.
WATER TANK PUMP ROOM:
E45: REPLACE DAMAGED 20MM THICK MARINE QUALITY PLYWOOD FOR WATER TANK
BASE.
PROPOSED MODIFICATION WORKS TO GROUND FLOOR PLAN: (DWG. NO.: AR-07)

PROPOSED 3D VISUAL VIEW FOR CUSTOMER COUNTER DESK: (DWG. NO.: AR-010)
PROPOSED FLOORING TILES LAYOUT AT GROUND FLOOR: (DWG. NO.: AR-013)
P52: REMOVE CAREFULLY EXISTING FLOORING TILES AND SKIRTING.
P53: SUPPLY & FIX NEW SKIRTING 300MM HIGH GRANITE.
P54: SUPPLY & FIX INTERNAL 1200X1200 MM NEW MARBLE TILES SEMI-GLOSSY
POLISHED WITH BORDER AND PATTERN.
P55: SUPPLY &FIX EXTERNAL 1200X1200 MM NEW GRANITE TILES RAFF FINISH WITH
PATTERN.
P56: PROVIDE MOCKUP SAMPLE FOR THE NEW FLOORING FOR CLIENT APPROVAL.

MEZZANINE FLOOR PLAN: (DWG. NO.: AR-015)


G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
H16: REPLACE DAMAGED / BROKEN 6MM THICK TOILET MIRROR.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
P57: REPLACE GRANITE FLOOR TILES BY USING CEMENT SAND SCREED.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.

FIRST FLOOR PLAN: (DWG. NO.: AR-016)


C18: SHIFT THE SERVER FROM AHU ROOM TO THE ATTACHED PANTRY.
G83A: SUPPLY AND FIX HEAVY DUTY SPRING HINGES TO WOODEN DOUBLE DOORS.
G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
G93A: CUTTING OF 400MMX400MM FOR CENTRAL A/C DIFFUSER AND RETURNER (TO
COORDINATE WITH MECHANICAL S.O) AS PER THE SITE CONDITIONS.
G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
K19: REMOVE THE EXISTING PANTRY CABINET FLOOR UNITS AND CART WAY.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
O04: REPLACE DAMAGED EXISTING WALL TILE WITH NEW CERAMIC WALL TILES USING
CEMENT BACKING.
P03: REPLACE DAMAGED (CERAMIC) FLOOR TILES AND SCREED WITH PORCELAIN FLOOR
TILES INCLUDING CEMENT SAND SCREED.
P04: REPLACE DAMAGED SKIRTING (ANY TYPE ) WITH PORCELAIN SKIRTING FIXING
WITH CEMENT , 100 TO 125MM HIGH.
P41: APPLY WATERPROOFING SYSTEM ON WET AREAS OF TOILET FLOOR SLABS.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q17: DISCONNECT WATER SUPPLY AND ELECTRICAL LINES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.
S08: CLEANING AND WASHING OF SINK UNITS.

SECOND FLOOR PLAN: (DWG. NO.: AR-017)


C18: SHIFT THE SERVER FROM AHU ROOM TO THE ATTACHED PANTRY.
G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
G93A: CUTTING OF 400MMX400MM FOR CENTRAL A/C DIFFUSER AND RETURNER (TO
COORDINATE WITH MECHANICAL S.O) AS PER THE SITE CONDITIONS.
G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
K19: REMOVE THE EXISTING PANTRY CABINET FLOOR UNITS AND CART WAY.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
O04: REPLACE DAMAGED EXISTING WALL TILE WITH NEW CERAMIC WALL TILES USING
CEMENT BACKING.
P03: REPLACE DAMAGED (CERAMIC) FLOOR TILES AND SCREED WITH PORCELAIN FLOOR
TILES INCLUDING CEMENT SAND SCREED.
P04: REPLACE DAMAGED SKIRTING (ANY TYPE) WITH PORCELAIN SKIRTING FIXING
WITH CEMENT, 100 TO 125MM HIGH.
P41: APPLY WATERPROOFING SYSTEM ON WET AREAS OF TOILET FLOOR SLABS.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q17: DISCONNECT WATER SUPPLY AND ELECTRICAL LINES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.
S08: CLEANING AND WASHING OF SINK UNITS.

THIRD FLOOR PLAN: (DWG. NO.: AR-018)


C18: SHIFT THE SERVER FROM AHU ROOM TO THE ATTACHED PANTRY.
G74B: REMOVE THE LOCK AND CONVERT THE EXISTING DOUBLE DOOR AS DOUBLE
SWING DOOR WITH SUPPLY AND FIX NECESSARY IRON MONGERY SUITABLE.
G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
G93A: CUTTING OF 400MMX400MM FOR CENTRAL A/C DIFFUSER AND RETURNER (TO
COORDINATE WITH MECHANICAL S.O) AS PER THE SITE CONDITIONS.
G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
O04: REPLACE DAMAGED EXISTING WALL TILE WITH NEW CERAMIC WALL TILES USING
CEMENT BACKING.
P03: REPLACE DAMAGED (CERAMIC) FLOOR TILES AND SCREED WITH PORCELAIN FLOOR
TILES INCLUDING CEMENT SAND SCREED.
P04: REPLACE DAMAGED SKIRTING (ANY TYPE) WITH PORCELAIN SKIRTING FIXING
WITH CEMENT , 100 TO 125MM HIGH.
P41: APPLY WATERPROOFING SYSTEM ON WET AREAS OF TOILET FLOOR SLABS.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q17: DISCONNECT WATER SUPPLY AND ELECTRICAL LINES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.
S08: CLEANING AND WASHING OF SINK UNITS.

FOURTH FLOOR PLAN: (DWG. NO.: AR-019)


C18: SHIFT THE SERVER FROM AHU ROOM TO THE ATTACHED PANTRY.
G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
G93A: CUTTING OF 400MMX400MM FOR CENTRAL A/C DIFFUSER AND RETURNER (TO
COORDINATE WITH MECHANICAL S.O) AS PER THE SITE CONDITIONS.
G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
J65: REPLACE THE EXISTING ALUMINUM WINDOW MARKED IN THE DRAWING WITH NEW
WINDOW OF SIMILAR SIZE 2100 X 2050, DOUBLE GLAZED.
K19: REMOVE THE EXISTING PANTRY CABINET FLOOR UNITS AND CART WAY.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
O04: REPLACE DAMAGED EXISTING WALL TILE WITH NEW CERAMIC WALL TILES USING
CEMENT BACKING.
P03: REPLACE DAMAGED (CERAMIC) FLOOR TILES AND SCREED WITH PORCELAIN FLOOR
TILES INCLUDING CEMENT SAND SCREED.
P04: REPLACE DAMAGED SKIRTING (ANY TYPE ) WITH PORCELAIN SKIRTING FIXING
WITH CEMENT , 100 TO 125MM HIGH.
P41: APPLY WATERPROOFING SYSTEM ON WET AREAS OF TOILET FLOOR SLABS.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q17: DISCONNECT WATER SUPPLY AND ELECTRICAL LINES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.
S08: CLEANING AND WASHING OF SINK UNITS.
NEW PARTITION:
F38: SUPPLY AND FIX NEW GYPSUM BOARD PARTITIONS (12.7MMTHICK), WITH
ACOUSTICALLY ENHANCED SOUND PROOFING GYPSUM.
U10: PREPARE NEW GYPSUM BOARD PARTITIONS SURFACE AND APPLY 1 COAT PRIMER
AND 2 COATS EMULSION PAINT.

TIOLET RENOVATION DETAILS: (DWG. NO.: AR-20)


FIFTH FLOOR PLAN: (DWG. NO.: AR-021)
C18: SHIFT THE SERVER FROM AHU ROOM TO THE ATTACHED PANTRY.
G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
G93A: CUTTING OF 400MMX400MM FOR CENTRAL A/C DIFFUSER AND RETURNER (TO
COORDINATE WITH MECHANICAL S.O) AS PER THE SITE CONDITIONS.
G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
K19: REMOVE THE EXISTING PANTRY CABINET FLOOR UNITS AND CART WAY.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q17: DISCONNECT WATER SUPPLY AND ELECTRICAL LINES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.
S08: CLEANING AND WASHING OF SINK UNITS.

SIXTH FLOOR PLAN: (DWG. NO.: AR-022)


C18: SHIFT THE SERVER FROM AHU ROOM TO THE ATTACHED PANTRY.
G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
G93A: CUTTING OF 400MMX400MM FOR CENTRAL A/C DIFFUSER AND RETURNER (TO
COORDINATE WITH MECHANICAL S.O) AS PER THE SITE CONDITIONS.
G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
K19: REMOVE THE EXISTING PANTRY CABINET FLOOR UNITS AND CART WAY.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q17: DISCONNECT WATER SUPPLY AND ELECTRICAL LINES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.
S08: CLEANING AND WASHING OF SINK UNITS.

NEW PARTITION:
F38: SUPPLY AND FIX NEW GYPSUM BOARD PARTITIONS (12.7MMTHICK), WITH
ACOUSTICALLY ENHANCED SOUND PROOFING GYPSUM.
U10: PREPARE NEW GYPSUM BOARD PARTITIONS SURFACE AND APPLY 1 COAT PRIMER
AND 2 COATS EMULSION PAINT.
F40: PROVIDE NEW DOOR OPENING INTO NEW GYPSUM BOARD PARTITION.
G01A: SUPPLY AND FIX NEW DOOR FRAME FOR SINGLE DOOR OF SIZE 50MM X 100MM
WITHOUT TRANSOM.
G14A: SUPPLY AND FIX NEW 45MM THICK SOLID TIMBER OPENABLE DOUBLE LEAF
PANEL DOOR.

PROPOSED MEETING ROOM LAYOUT: (DWG. NO.: AR-023)


C30: ALL EXISTING LIGHT FIXTURES WITH ALL ACCESSORIES TO BE DISMANTLED
CAREFULLY FROM THE SITE, AND TO BE DELIVERED TO BMD STORE.
C31: REMOVE EXISTING FALSE CEILING TILES FROM THE ALLOCATION WORKING AREA
(MEETING ROOM AT 6TH FLOOR LEVEL).
C32: REMOVE EXISTING WOODEN FOLDING DOOR, AND TO BE DELIVERED TO BMD
STORE.
C33: REMOVE EXISTING 2 NOS OF SINGLE WOODEN HINGED DOORS, AND TO BE
DELIVERED TO BMD STORE.
C34: SUPPLY AND FIX EQUIPMENT'S SUCH AS: PROJECTOR, SCREEN DISPLAY,SPEAKER IF
REQUIRED.CONTRACTOR TO USE ALL THE EXISTING CONNECTION FOR THESE
EQUIPMENT'S.
G104: SUPPLY 4 NOS OF WOODEN DECORATION PANELS IN CLASSIC DESIGN.
G105: SUPPLY OF WOODEN DADO 150MM AT RIGHT AND LEFT SIDES OF THE MEETING
ROOM.
G106: SUPPLY AND INSTALL MANUAL FOLDING DOOR WITH FIXED GLASS.
G107: SUPPLY AND INSTALL 2 NOS OF SHUTTER SINGLE DOOR ONLY WITH ARCHITRAVES.
N19: SUPPLY AND FIX NEW 600X600 MM GYPSUM BOARDS FALSE CEILING.
O19: PREPARE THE WALL SURFACE, SUPPLY & FIX HEAVY DUTY WALL COVER PAPERS
WASHABLE.
P52: REMOVE CAREFULLY EXISTING FLOORING TILES AND SKIRTING.
P53: SUPPLY & FIX NEW SKIRTING 300MM HIGH GRANITE BY USING CEMENT SAND
SCREED AT AT EXTERNAL PARAMETER OF THE BUILDING.
P54: SUPPLY & FIX INTERNAL 1200X1200 MM NEW MARBLE TILES SEMI-GLOSSY
POLISHED WITH BORDER AND PATTERN.
P56: PROVIDE MOCKUP SAMPLE FOR THE NEW FLOORING FOR CLIENT APPROVAL.

SEVENTH FLOOR PLAN: (DWG. NO.: AR-025)


G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
G93A: CUTTING OF 400MMX400MM FOR CENTRAL A/C DIFFUSER AND RETURNER (TO
COORDINATE WITH MECHANICAL S.O) AS PER THE SITE CONDITIONS.
G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
O19: PREPARE THE WALL SURFACE, SUPPLY & FIX HEAVY DUTY WALL COVER PAPERS
WASHABLE.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.
S08: CLEANING AND WASHING OF SINK UNITS.

TIOLET AND PANTRY WORKS DETAILS: (DWG. NO.: AR-026)


EIGTH FLOOR PLAN: (DWG. NO.: AR-028)
F20A: PROVIDE DOOR OPENING TO 200MM THICK BLOCK WALL INCLUDING CONCRETE
LINTEL BEAM.
G03: SUPPLY AND FIX DOOR FRAME FOR SINGLE DOOR OF SIZE 50MM X 200MM WITHOUT
TRANSOM.
G13B: REPLACE SHUTTER SINGLE DOOR ONLY WITH ARCHITRAVES WITH
IRONMONGERIES.
G13C: REPLACE SHUTTER DOUBLE DOOR ONLY WITH ARCHITRAVES WITH
IRONMONGERIES.
G13D: SUPPLY AND FIX SINGLE DOOR ONLY WITH ARCHITRAVES WITH IRONMONGERIES.
G81B: SUPPLY AND FIX HEAVY TYPE CLOSER TO NEW DOORS SHUTTER.
G93: CUTTING OF 200MM DIAMETER HOLE TO GYPSUM PLASTER BOARD CEILING DUE TO
ELECTRICAL INSTALLATION.
G93A: CUTTING OF 400MMX400MM FOR CENTRAL A/C DIFFUSER AND RETURNER (TO
COORDINATE WITH MECHANICAL S.O) AS PER THE SITE CONDITIONS.
G103: BLOCK UP THE HOLES TEMPORARY USING PLASTIC SHEET.
N06: REPLACE DAMAGED EXISTING CEILING WITH NEW VINYL FACED GYPSUM CEILING
OF SIZE 600MM X 600MM X 9.5MM.
N09: REPLACE THE EXISTING CEILING WITH NEW REFLECTED WATERPROOFING GYPSUM
PLASTER BOARD CEILING COMPLETE WITH FRAME, SUSPENSIONS.
N21: HIDDEN THE INTERNET ROUTER INSIDE THE CEILING INCLUDING ALL RELATIVE
WORKS.
P58: POLISHING EXISTING GRANITE FLOOR TILES.
Q21: EXCAVATE FOR NEW FLOOR TRAPS INCLUDING CONNECTION TO THE DRAINAGE AT
AHU ROOM AND PROVIDE FLOOR TRAP INCLUDING PLASTIC COVER.
R01: REPLACE DAMAGED WESTERN WATER CLOSET.
S08: CLEANING AND WASHING OF SINK UNITS.

ROOFDECK FLOOR PLAN: (DWG. NO.: AR-029)


E60: CONTRACTOR IS REQUIRED TO DISMANTLE THE EXISTING FLAG POLE WITH ALL
EXISTING SUPPORTS.
G81: REPLACE OVERHEAD DOOR CLOSER (HEAVY).
J18: REPLACE DAMAGED ALUMINUM HANDLE TO ALUMINUM DOORS.
P25A: REPLACE DAMAGED STAIRCASE STEP CERAMIC TILES INCLUDING CEMENT-SAND
SCREED.
Q20: CONNECT THE EXITING DRAIN PIPE WITH THE EXTERNAL GROUND NEAREST
MANHOLE INCLUDING ALL RELATIVE WORKS.