Professional Documents
Culture Documents
Donghwa Pneutec 166 - Wziywe
Donghwa Pneutec 166 - Wziywe
Donghwa Pneutec 166 - Wziywe
History 04 The expert of air compressor with the advanced research and development capability and outstanding ability, DongHwa
Pneutec achieved the air compressed system technology and skilled manufacturing technology to serve the highly effi-
Business & Affiliates 05 ciency and high quality products to our customers. The excellent service of DongHwa Pneutec makes the end-user easy to
use our products for long period of time.
Product 06
Consequently, the global market competitiveness was achieved, and we supply our products to the top shipbuilders
NeX-B/Ar Series – Tank-intergrated Screw Compressor 07 and power plant and so on. Moreover, the assertive management and high-quality strategy allowed us to develop for-
eign markets, so that we directly exported our products to owner in abroad and it became a source of foreign exchanges.
NeX Series – Oil-injection Screw Compressor 08 - 11
The ‘compressed air’ is an essential part of all industry and every people looks for life in clean and pleasant environment.
NeF Series – Oil-free Screw Compressor 12 - 13 So, we are keeping customer’s satisfaction as our top priority, we will continue our utmost efforts to conduct researches.
We will make an effort to contribute growth of local economy and technology development in related industries.
NeX-VA Series – High Pressure Piston Compressor 14
Location 23
2 3
History Business
Half century of challenge, pioneer, change and innovation.
Jump up to be world-wide Donghwa Pneutec with a spirit to turn impossibility into possibility.
“We are committed to grow up to become a 100-year-old enterprise by satisfying all of our clients through
high technology and know-how accomplished on a basis of confidence.”
Industrial Compressor
Compressed air, like electricity, is an essential power source for all industries. It is non-environmentally
polluting, safe from explosion and ignition, and easy to store and transport; therefore, it is being used in
various fields including construction, tools, chemicals, steel, food, and semiconductors.
2010 ~2016 2000 ~2009 1970 ~1999 DongHwa Pneutec’s industrial compressors are being provided and used in various product groups such
as oil free or oil injection; screw or piston; air cooled or water cooled; and others meeting both the pressure
and volume customers need.
2011 2000 1974
01. Certified as Management Innovation SME (MAIN-BIZ) 03. Released marine air compressor for large-sized
ships (H-TYPE)
07. Established Jonghap Maritime Inc. Plant Compressors
02. Established additional domestic and overseas The specifications of the compressor in the fields of on shore and off shore are very particular. Many
agencies compressor manufacturers are trying to enter this market, but the markets development for this field is
2001 1984 not easy.
03. Certified ISO 14001 (Environmental Management 03. Moved to Noksan Industrial Complex
System) 11. Technical cooperation with MATSUBARA Inc.
Donghwa Pneutec’s compressors for plants are being supplied and used for various on shore and off
05. Developed refrigerant compressors and gas 2002 shore fields such as FPSOs, SEMI SUBMERSIBLE RIGs, and DRILL SHIPs as well as a variety of domestic and
12. Commissioned No. 1 marine air compressor
compressors for SOx reduction device international power plants.
07. Completed localization of H-TYPE componets (The first domestic production of marine air
(TANABE, INC.) compressors; CMS Series)
10. Certified as Technology Innovation SME (MAIN-BIZ)
11. Awarded Ten Million Dollar Export Tower 11. Separated its affiliate to Jonghap Pneutec Marine Compressors
12. Selected as Busan City Leading Company
2006 1994 Compressors, which are essential equipment to start ship’s engine, should be manufactured based on
technology ensuring high reliability in terms of durability and safety of products, for the ships cannot
12. Technical cooperation with TANABE, Inc.
10. Established own R&D Center operate when failure occurs to this product.
2012
12. Developed ultra-high pressure compressor 11. Awarded Three Million Dollar Export Tower
Donghwa Pneutec’s marine compressors not only occupy the highest market share in the world market,
for breathing (NeX-H Series)
but they have also been used for ballast water treatment systems, air lubrication system for fuel-efficiency
2007 1996 recently.
2013 06. Developed and applied patent for the world’s 04. Released marine screw type air compressors
03. Developed small-sized, light weight medium (ZS Series)
Affiliates
first marine low-vibration air compressor
pressure air compressor (NeX-VA Series) (HLV Series)
06. Acquired OHSAS 18001 Certificate (Occupational
Health and Safety Management System) 10. Changed its name to Donghwa Pneutec
1997
04. Released marine air-cooled air compressors
06. Selected as ATC Business (Advanced Technology 11. Awarded Five Million Dollar Export Tower (AHW Series)
Center)
4 5
Product Oil-injection Screw Compressor NeX-B / Ar Series Tank intergrated / Air Dryer intergrated (option)
NeX-B / Ar Series
Tank intergrated
Oil-injection Screw Compressor Air Dryer intergrated (option)
Motor Output(KW) Capacity(m³/min) Pressure(Bar) Cooling Driven Method Starting Method
NeX Series
Air cooled, Water cooled
Oil-injection Screw Compressor / Inverter (option)
Motor Output(KW) Capacity(m³/min) Pressure(Bar) Cooling Driven Method Starting Method
Oil-free Screw Compressor NeF Series Air cooled, Water cooled / Inverter (standard)
Compact Design Compact, tank-integrated unit with easy installation and operation in small or medium-size industrial sites
Motor Output(KW) Capacity(m³/min) Pressure(Bar) Cooling Driven Method Starting Method
4.5 ~ 420kW Air cooled / Inverter / Low-noise Minimized noise by applying a low-noise cooling fan and high-efficient absorbing materials with the finest design
5.7 ~ 71.6㎥ / min 7 ~ 9 bar Direct
(60 ~ 560Hp) Water cooled Reactor Low-vibration Anti-vibration mounting pad and piping line to ensure to minimize the vibration
High efficiency High compression efficiency compared to piston type, operation for 24 hours a day, 365 days a year, low maintenance
11 ~ 45kW
(15 ~ 60Hp)
40 ~ 200㎥ / hr ~ 30 bar Air cooled Direct
D.O.L / Star-
Delta Applications
H Series
L.O Capacity (Liter) 8 10
High Pressure Piston Compressor Water cooled Air Tank Capacity (Liter) 170 280
Motor Output(KW) Capacity(m³/min) Pressure(Bar) Cooling Driven Method Starting Method
Outlet Size PT 1/2” PT 1”
15 ~ 132kW D.O.L / Star- Noise Level (dB(A) ± 3) 66 67 69 70
65 ~ 610㎥ / hr ~ 30 bar Water cooled Direct
(20 ~ 175Hp) Delta
1200x600x1280 1200x600x1280 1500 x 680 x 1450 1500x750x1450 1500 x680x1450
Size (LxWxH mm)
(1550x680x1450) (1550x680x1450) (1600 x 680 x 1450) (1600x750x1450) (1600x680x450)
High Pressure Piston Compressor NeX-H Series Air cooled Air Dryer intergrated (option) Include 2 filters
Motor Output(KW) Capacity(m³/min) Pressure(Bar) Cooling Driven Method Starting Method Weight (Kg) 350 (400) 350 (400) 550 (600) 550 (600)
6 7
( i ) is the model with inverter and the data
NeX Series Air cooled
NeX A / B Series Air / Water cooled / Inverter (option)
in the ( ) is the specification of model with inverter.
Oil-injection Screw Compressor
Model NeX- 37A 37AB(i) 37AG(i) 45AB(i) 45AG(i) 55AB(i) 55AG(i) 75AB(i) 75AG(i)
Model NeX- 90AB(i) 90AG(i) 110AB(i) 110AG(i) 150AB(i) 150AG(i) 185AB(i) 185AG(i)
Low-noise Minimized noise by applying a low-noise cooling fan and high-efficient absorbing materials with the finest design 7 bar 17.2 / 604 20.2 / 713 27.2 / 961 31.3 / 1105
Capacity 8 bar 15.6 / 551 18.6 / 657 25.1 / 886 31.2 / 1102
Low-vibration Anti-vibration mounting pad and piping line to ensure to minimize the vibration (㎥ / min / cfm)
9 bar 15.3 / 540 17.8 / 629 25.0 / 883 31.1 / 1098
High efficiency High compression efficiency compared to piston type, Operation for 24 hours a day,365 days a year, low maintenance
Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60
cost due to long life and high safety
Motor Ouput (kW / Hp) 90 / 120 110 / 150 150 / 200 185 / 250
Starting Type Star - Delta (Inverter)
Driven Type Direct
Applications Cooling Type Air cooled
L.O Capacity (Liter) 40 100
Outlet Size 65A Flange 80A Flange
Noise Level (dB(A) ± 3) 78 82 85
( i ) is the model with inverter and the data
NeX Series Air cooled in the ( ) is the specification of model with inverter. 2500(2900)x 2400(2800)x 2650(3050)x 2550(2950)x 2700(3200)x 2600(3100)x 2800(3300)x 2700(3200)x
Size (LxWxH mm) 1500(1600)x 1400(1500)x 1500(1600)x 1400(1500)x 1500(1600)x 1400(1500)x 1700(1900)x 1600(1800)x
Model NeX- 15A 15AB(i) 22A 22AB(i) 22AG(i) 30A 30AB(i) 30AG(i) 1800(1800) 1800(1800) 1950(1950) 1950(1950) 2000(2000) 2000(2000) 2100(2100) 2100(2100)
7 bar 2.7 / 95 3.8 / 134 4.6 / 162 Weight (Kg) 2050 (2150) 2000 (2100) 2450 (2550) 2400 (2500) 3350 (3450) 3300 (3400) 3850 (4050) 3800 (4000)
Capacity 8 bar 2.5 / 88 3.7 / 131 4.5 / 159
(㎥ / min / cfm)
Model NeX- 220AB(i) 220AG(i) 260AB(i) 260AG(i) 300AB(i) 300AG(i) 350AB(i) 350AG(i)
9 bar 2.3 / 81 3.6 / 127 4.3 / 152
7 bar 38.1 / 1346 44.3 / 1565 49.3 / 1741 64.4 / 2274
Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60
Capacity 8 bar 36.5 / 1289 42.2 / 1490 49.2 / 1738 -
(㎥ / min / cfm)
Motor Ouput (kW / Hp) 15 / 20 22 /30 30 /40
9 bar 34.6 / 1222 42.0 / 1483 49.1 / 1734 -
Starting Type D.O.L (Inverter) Star - Delta (Inverter) Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60
Driven Type Poly belt Direct Poly belt Direct Poly belt Direct Motor Ouput (kW / Hp) 220 / 300 260 / 350 300 / 400 350 /470
Starting Type Star - Delta (Inverter)
Cooling Type Air cooled
Driven Type Direct
L.O Capacity (Liter) 18 20 20 Cooling Type Air cooled
Outlet Size PT 3/4” PT 1 1/4” L.O Capacity (Liter) 200 300
Outlet Size 80A Flange 100A Flange
Noise Level (dB(A) ± 3) 70 73 71 73 72
Noise Level (dB(A) ± 3) 90
1220x 1175(1450)x 950x 1300(1600)x 1400(1600)x 950x 1500(1600)x 1400(1600)x 2900(3400)x 2800(3300)x 3200(3650)x 3100(3550)x 3600(4100)x 3500(4000)x 4100(4600)x 4000(4500)x
Size (LxWxH mm) 950x 910(960)x 1220x 963(1000)x 963(1000)x 1220x 963(1000)x 963(1000)x Size (LxWxH mm) 1900(2000)x 1800(1900)x 2300(2400)x 2200(2300)x 2400(2900)x 2300(2800)x 2600(3100)x 2500(3000)x
1315 1221(1450) 1400 1250(1400) 1250(1400) 1400 1250(1400) 1250(1400) 2100(2100) 2100(2100) 2100(2100) 2100(2100) 2200(2200) 2200(2200) 2300(2300) 2300(2300)
Weight (Kg) 4500 (4700) 4450 (4850) 5050 (5250) 5000 (5200) 5550 (5850) 5500 (5800) 6050 (6350) 6000 (6300)
Weight (Kg) 520 510 (565) 650 695 (745) 690 (730) 655 715 (750) 695 (740)
1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.)
1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.) 3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%.
3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%. 5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 9 bar. Please contact us.
5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 9 bar. Please contact us. 7. High Voltage Motor is available
8 9
( i ) is the model with inverter and the data ( i ) is the model with inverter and the data
NeX Series Water cooled in the ( ) is the specification of model with inverter. NeX Series Water cooled in the ( ) is the specification of model with inverter.
Model NeX- 15W 15WB(i) 22W 22WB(i) 22WG(i) 30W 30WB(i) 30WG(i) Model NeX- 90WB(i) 90WG(i) 110WB(i) 110WG(i) 150WB(i) 150WG(i) 185WB(i) 185WG(i)
7 bar 2.7 / 95 3.8 / 134 4.6 / 162 7 bar 17.2 / 604 20.2 / 713 27.2 / 961 31.3 / 1105
Capacity Capacity
8 bar 2.5 / 88 3.7 / 131 4.5 / 159 8 bar 15.6 / 551 18.6 / 657 25.1 / 886 31.2 / 1102
(㎥ / min / cfm) (㎥ / min / cfm)
9 bar 2.3 / 81 3.6 / 127 4.3 / 152 9 bar 15.3 / 540 17.8 / 629 25.0 / 883 31.1 / 1098
Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60 Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60
Motor Ouput (kW / Hp) 15 / 20 22 /30 30 /40 Motor Ouput (kW / Hp) 90 / 120 110 / 150 150 / 200 185 / 250
Starting Type D.O.L (Inverter) Star - Delta (Inverter) Starting Type Star - Delta (Inverter)
Driven Type Poly belt Direct Poly belt Direct Poly belt Direct Driven Type Direct
1300x 1250(1400)x 1250x 1300(1600)x 1500(1600)x 1250x 1500(1600)x 2500(2900)x 2400(2800)x 2650(3050)x 2550(2950)x 2800(3300)x 2700(3200)x 2900(3400)x 2800(3300)x
Size (LxWxH mm) 1100x 1100(1100)x 1300x 1100(1300)x 1200(1300)x 1300x 1200(1300)x Size (LxWxH mm) 1700(1800)x 1600(1700)x 1700(1800)x 1600(1700)x 1900(2000)x 1800(1900)x 2000(2100)x 1900(2000)x
1110 1270(1300) 1300 1300(1400) 1300(1400) 1300 1300((1400) 1900(1900) 1900(1900) 1900(1900) 1900(1900) 1900(1900) 1900(1900) 2000(2000) 2000(2000)
Weight (Kg) 535 560 (585) 675 685 (760) 725 (760) 680 715 (770) 730 (770)
Weight (Kg) 2150 (2250) 2100 (2200) 2550 (2650) 2500 (2600) 3450 (3550) 3400 (3500) 3950 (4150) 3900 (4100)
Model NeX- 37W 37WB(i) 37WG(i) 45WB(i) 45WG(i) 55WB(i) 55WG(i) 75WB(i) 75WG(i)
Model NeX- 220WB(i) 220WG(i) 260WB(i) 260WG(i) 300WB(i) 300WG(i) 350WB(i) 350WG(i) 400WG(i)
7 bar 6.6 / 233 7.2 / 254 10.4 / 367 13.6 / 480 7 bar 38.1 / 1346 44.3 / 1565 49.3 / 1741 64.4 / 2274 -
Capacity Capacity
8 bar 5.9 / 208 6.8 / 240 9.6 / 339 13.1 / 463 8 bar 36.5 / 1289 42.2 / 1490 49.2 / 1738 - 60.3 / 2130
(㎥/ min / cfm) (㎥/ min / cfm)
9 bar 5.6 / 198 6.6 / 233 9.2 / 325 12.5 / 441 9 bar 34.6 / 1222 42.0 / 1483 49.1 / 1734 - 60.2 / 2126
Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60 Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60
Motor Ouput (kW / Hp) 37 / 50 45 / 60 55 / 75 75 / 100 Motor Ouput (kW / Hp) 220 / 300 260 / 350 300 /400 350 /470 400/540
Starting Type Star - Delta (Inverter) Starting Type Star - Delta (Inverter)
Driven Type Poly belt Direct Driven Type Direct
Cooling Type Water cooled Cooling Type Water cooled
L.O Capacity (Liter) 20 40 L.O Capacity (Liter) 200 300
Outlet Size PT 1 1/2” PT 2” Outlet Size 80A Flange 100A Flange
C.W Inlet / Outlet Size PT 1 1/4” PT 1 1/2” C.W Inlet / Outlet Size 65A Flange 80A Flange
Noise Level (dB(A) ± 3) 73 74 Noise Level (dB(A) ± 3) 89
Weight (Kg) 895 990 (1010) 1015 (1040) 1550 (1590) 1672 (1710)
Weight (Kg) 4650 (4850) 4600 (4800) 5550 (5850) 5500 (5800) 5850 (6050) 5800 (6000) 6350 (6650) 6300 (6600) 7000 (7300)
1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.)
3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%. 1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.)
5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 9 bar. Please contact us. 3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%.
7. High Voltage Motor is available. Please consult us whether to install an inverter or not. ㅣ 8. Normal type without an inverter is available. Please contact us. 5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 9 bar. Please contact us.
7. High Voltage Motor is available
10 11
NeF Series Water cooled
Oil-free Screw Compressor NeF Series Air / Water cooled / Inverter(standard) Model NeF- 37Wi 45Wi 55Wi 75Wi 90Wi 110Wi 160Wi 200Wi
7 bar 5.0 / 177 6.6 / 233 8.4 / 297 11.6 / 410 15.4 / 544 18.4 / 650 24.2 / 855 32.5 / 1148
Capacity
8 bar 4.9 / 173 6.3 / 222 7.9 / 279 10.8 / 381 13.8 / 487 17.5 / 618 22.5 / 795 30.1 / 1063
(㎥ / min / cfm)
9 bar 4.8 / 170 5.7 / 201 7.1 / 251 10.4 / 367 12.4 / 438 16.3 / 576 21.6 / 763 28.6 / 1010
Motor Ouput (kW / Hp) 37 / 50 45 / 60 55 / 75 75 / 100 90 /120 110 / 150 160 / 215 200 / 270
Convenience Eased monitoring of all parameters and running conditions at once through 10” large color LCD
Weight (Kg) 2550 2600 2700 3000 3230 3500 3800 5200
7 bar 45.8 / 1618 55.8 / 1971 61.6 / 2176 66.6 / 2352 71.6 / 2529
Model NeF- 37Ai 45Ai 55Ai 75Ai 90Ai 110Ai 160Ai 200Ai 9 bar 42.1 / 1487 48.3 / 1706 55.1 / 1946 59.1 / 2087 64.1 / 2264
7 bar 5.0 / 177 6.6 / 233 8.4 / 297 11.6 / 410 15.4 / 544 18.4 / 650 24.2 / 855 32.5 / 1148 Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60
Capacity
8 bar 4.9 / 173 6.3 / 222 7.9 / 279 10.8 / 381 13.8 / 487 17.5 / 618 22.5 / 795 30.1 / 1063 Motor Ouput (kW / Hp) 290 / 390 320 / 430 360 / 485 390 / 525 420 / 565
(㎥ / min / cfm)
9 bar 4.8 / 170 5.7 / 201 7.1 / 251 10.4 / 367 12.4 / 438 16.3 / 576 21.6 / 763 28.6 / 1010
Starting Type Inverter
Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60
Driven Type Direct
Motor Ouput (kW / Hp) 37 / 50 45 / 60 55 / 75 75 / 100 90 /120 110 / 150 160 / 215 200 / 270
Cooling Type Water cooled
Starting Type Inverter
Outlet Size 100A Flange 125A Flange
Driven Type Direct
Cooling Type Air cooled C.W Inlet / Outlet Size 80A Flange 100A Flange
Outlet Size PT 1 1/2” PT 2” 65A Flange 80A Flange Noise Level (dB(A) ± 3) 93 95
Weight (Kg) 2700 2850 2900 3000 3400 3600 3900 5100 Weight (Kg) 6200 6900 7200 7800 8000
1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.) 1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.)
3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%. 3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%.
5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 9 bar. Please contact us. ㅣ 7. High Voltage Motor is 5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 9 bar. Please contact us. ㅣ 7. High Voltage Motor is
available. Please consult us whether to install an inverter or not. ㅣ 8. INormal type without an inverter is available. Please contact us. available. Please consult us whether to install an inverter or not. ㅣ 8. INormal type without an inverter is available. Please contact us.
12 13
High Pressure Piston Compressor NeX-VA Series Air cooled High Pressure Piston Compressor CM, AH Series Air cooled
Applications
Applications
NeX-VA Series Air cooled CM, AH Series Air cooled The data in the ( ) is the specification of engine driven type.
Model NeX- 40VA 60VA 80VA 100VA 130VA 160VA 200VA
Model CMA-15 CMA-15E AHV-20 AHV-20E AHV-30 AHV-30E AHW-40A AHW-60A
Working Pressure (bar / psi) 7 ~ 30 / 102 ~ 435 Working Pressure (bar / psi) 7 ~ 30 / 102 ~ 435
Cylinder 2 Cylinder 1 2 3
Capacity (㎥ / hr / cfm) 40 / 24 60 / 35 80 / 47 100 / 59 130 / 77 160 / 94 200 / 118 Capacity (㎥ / hr / cfm) 15 / 9 20 / 12 30 /18 40 / 24 60 / 35
Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60 Power Supply (V/Ph/Hz) 200 ~ 460 / 3 / 50 ~ 60
Driven Type Direct Driven Type V-belt Direct V-belt Direct V-belt Direct
L.O Capacity (Liter) 5.8 11 L.O Capacity (Liter) 2.1 2.8 2.8 5.5
Outlet Size 30K 25A Flange 30K 40A Flange Outlet Size 30K 15A Flange 30K 25A Flange
1450x 1500x 1550x 1500x 1600x 905x 1306x 1100x 1878x 1100x 1878x 1480x 1520x
Size (LxWxH mm) 1250x1060x800 Size (LxWxH mm)
1070x980 1070x980 1070x980 1070x980 1070x980
456x790 516x875 825x820 606x895 825x820 606x895 920x876 920x876
Weight (Kg) 490 850 860 1030 900 1030 Weight (Kg) 175 271 420 436 430 436 630 655
1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.) 1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.)
3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%. 3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%.
5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 30 bar. Please contact us. 5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 30 bar. Please contact us.
14 15
High Pressure Piston Compressor NeX-M Series Water cooled High Pressure Piston Compressor H Series Water cooled
Applications
Applications
NeX-M Series Water cooled The data in the ( ) is the specification of 50Hz. H Series Water cooled The data in the ( ) is the specification of 50Hz.
Model NeX- 155M 200M 320M 400M Model H-63 H-64 H-73 H-74 H-264 H-273 H-274 H-373 H-374
Working Pressure (bar / psi) 7 ~ 30 / 102 ~ 435 Working Pressure (bar / psi) 7 ~ 30 / 102 ~ 435
1200 RPM 110 / 65 140 / 82 220 / 129 275 / 162 1200 RPM 65 / 38 85 / 50 110 / 65 140 / 82 170 / 100 220 / 129 275 / 162 330 / 194 415 / 244
Capacity Capacity
(1500 RPM) (135 / 79) (175 / 103) (275 / 162) (340 / 200) (1500 RPM) (80 / 47) (105 / 62) (135 / 79) (175 / 103) (210 / 124) (275 / 162) (340 / 200) (410 / 241) (515 / 303)
(㎥/hr / cfm) (㎥/hr / cfm)
1800 RPM 160 / 94 205 / 121 325 / 191 405 / 238 1800 RPM 95 / 56 125 / 74 160 / 94 205 / 121 250 / 147 325 / 191 405 / 238 485 / 285 610 / 359
1200 RPM 30 / 40 45 / 60 55 / 75 1200 RPM 15 / 20 19 / 25 30 / 40 37 / 50 45 / 60 55 / 75 75 / 100 90 / 120
Motor 30 Motor 30
Ouput (1500 RPM) (30 / 40) (37 / 50) (60 / 80) (75 / 100) Ouput (1500 RPM) (19 / 25) (30 / 40) (37 / 50) (55 / 75) (60 / 80) (75 / 100) (90 / 120) (110 / 150)
(kW/Hp) Bar (kW/Hp) Bar
1800 RPM 37 / 50 55 / 75 75 / 100 90 / 120 1800 RPM 22 / 30 30 / 40 37 / 50 55 / 75 60 / 80 75 / 100 90 / 120 110 / 150 132 / 177
1200 RPM 19 / 25 22 / 30 37 / 50 45 / 60 1200 RPM 11 / 15 15 / 20 19 / 25 22 / 30 30 / 40 37 / 50 45 / 60 55 / 75 75 / 100
Motor 7~9 Motor 7~9
Ouput (1500 RPM) (22 / 30) (30 / 40) (45 / 60) (55 / 75) Ouput (1500 RPM) (15 / 20) (22 / 30) (30 / 40) (45 / 60) (55 / 75) (75 / 100) (90 / 120)
(kW/Hp) Bar (kW/Hp) Bar
1800 RPM 30 / 40 37 / 50 55 / 75 75 / 100 1800 RPM 19 / 25 30 / 40 37 / 50 55 / 75 75 / 100 90 / 120 110 / 150
1200 RPM 19 / 25 30 / 40 45 / 60 55/ 75 1200 RPM 15 / 20 19 / 25 30 / 40 45 / 60 55 / 75 60 / 80 75 / 100
Motor Motor 15
Ouput 15 Ouput
(1500 RPM) (30 / 40) (55 / 75) (75 / 100) (1500 RPM) (15 / 20) (22 / 30) (30 / 40) (45 / 60) (55 / 75) (75 / 100) (90 / 120)
Bar (kW/Hp) Bar
(kW/Hp) 1800 RPM 19 / 25 30 / 40 37 / 50 55 / 75 60 / 80 75 / 100 90 / 120 110 / 150
1800 RPM 37 / 50 37 / 50 75 / 100
1200 RPM 30 / 40 45 / 60 55 / 75 1200 RPM 15 / 20 19 / 25 30 / 40 37 / 50 45 / 60 55 / 75 75 / 100 90 / 120
Motor Motor 25
Ouput 25 Ouput
(1500 RPM) (30 / 40) (37 / 50) (55 / 75) (75 / 100) (1500 RPM) (19 / 25) (30 / 40) (37 / 50) (45 / 60) (55 / 75) (75 / 100) (90 / 120) (110 / 150)
Bar (kW/Hp) Bar
(kW/Hp) 1800 RPM 22 / 30 30 / 40 37 / 50 45 / 60 55 / 75 75 / 100 90 / 120 110 / 150 132 / 177
1800 RPM 37 / 50 45 / 60 75 / 100 90 / 120
Power Supply (V/Ph/Hz) 200 ~ 460 / 3 / 50 ~ 60 Power Supply (V/Ph/Hz) 200 ~ 460 / 3 / 50 ~ 60
Starting Type D.O.L or Star - Delta Starting Type D.O.L or Star - Delta
Driven Type Direct Driven Type Direct
Cooling Type Water cooled Cooling Type Water cooled
L.O Capacity (Liter) 16 33 L.O Capacity (Liter) 12 25 38
Outlet Size 30K 40A Flange 30K 50A Flange Outlet Size 30K 32A Flange 30K 40A Flange 30K 50A Flange 30K 65A Flange
C.W Inlet / Outlet Size 5K 25A Flange 5K 32A Flange C.W Inlet / Outlet Size 5K 25A Flange 5K 32A Flange 5K 40A Flange
Size (LxWxH mm) 1455x700x1170 1470x700x1170 1750x700x1336 1780x700x1336 Size (LxWxH mm) 1550x945x1300 1595x945x1300 1725x945x1336 1740x945x1336 2020x945x1336 2035x945x1336 2050x945x1336 2800x1050x1406 2890x1050x1406
Weight (Kg) 930 980 1400 1450 Weight (Kg) 845 865 1020 1070 1445 1490 1530 2240 2340
1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.) 1. Some specifications in this catalogue can be changed without notice. ㅣ 2. The maximum ambient temperature is 45 °C. (Please consult us in case of above 55 °C.)
3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%. 3. The flow is under the condition of ambient temperature 20 °C, humidity 60 % and at atmospheric pressure. ㅣ 4. Capacity and power deviation are approximately ± 5%.
5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 30 bar. Please contact us. 5. Dimension size can be changed according to the valve option. ㅣ 6. Production is available with the pressure unit over 30 bar. Please contact us.
16 17
High Pressure Piston Compressor NeX-H Series Air cooled
Air Cleaning System
Applications
HXK Series
Midium-Large Refrigerated Air Dryer
NeX-H Series Air cooled The HXK series utilizes advanced heat exchanger, separation and refriger-
ation technology. It’s a revolutionary that uses an innovative, simplified
Model NeX- 3.7H 5.5H 7.5H 15H 22H 37H refrigeration circuit to provide dependable operation, low operating cost
Working Pressure (bar / psi) 200 ~ 350 / 2900 ~ 5076 and versatile installation. Performs in rated conditions of 75 to 6000scfm.
Cylinder 3 4
JHT Series
350 Bar 5.5 / 7.5 7.5 / 10 11 / 15 19 / 25 30 / 40 45 / 60
200 Bar
The JHT series replaces four separate components; the aftercooler, separa-
tor, dryer and filter, with one compact package. Guaranteed to cool, dry and
Power Supply (V / Ph / Hz) 200 ~ 460 / 3 / 50 ~ 60
clean your compressed air JHT Series dryers are the smart choice.
Starting Type D.O.L Star - Delta
18 19
Info of Geunine Spare Parts
HRE Series
Desiccant Air Dryers (External Heated)
The HRE Series desiccant dryers are designed and built for plant & instru-
ment air application where the lower purge consumption is required. HRE
Series dryers are using the small portion of purge air heated by external
heater for regeneration.
JBP Series
Blower Purge Desiccant Air Dryers
As the air compressor is the most costly system component to purchase and,
it uses more electrical energy than the rest of the system combined, it is wise
to endure that the smallest air compressor is installed. JBP Series dryers are
100% efficient at delivering full supply-side compressor capacity. Therefore
users benefit from the ability to purchase a less expensive air compressor
and, a 20% reduction in compressor operating costs.
NGF Series
Take a long term view on quality and make an investment.
Air Line Filter
This is the reason why you have to use the genuine spare parts from
Energy costs continue to escalate globally, having a negative impact on plant
profitablility and production costs. Sustainability initiatives in plant operations
DongHwa Pneutec.
must be implemented to maintain a competitive advantage.
Air treatment manufacturers are challenged to design equipment that is cost Our genuine spare parts are optimized for our respective products and this
effective. Delivers optimum performance and consumes less energy. The NGF
is the only way to ensure the best performance and safety.
Series is the ideal solution to remove contamination from compressed air
systems and save energy. We provide same quality assurance program for both original parts and
The NGF Series employs technological advancements in filtration materials genuine spare parts.
and design to ensure premium compressed air quality and low operational
costs.
Unauthorized spare parts other than genuine spare parts of DongHwa
Pneutec may cause degradation of performance or malfunction.
JAC Series
After Cooler
If there is moisture in the compressed air, this leads various industrial
Purchase Inquiry
pneumatic devices to lower qualities and shorter durability. Therefore, the
compressed air should be dried and chilled before using it. JAC series after Sales Team sales@dhkomp.co.kr
cooler, and essential supplementary device to supply lower temperature A/S Team service@dhkomp.co.kr
compressed air, condensate the water vapor and remove it with cooling down TEL 051-974-4800
high temperature and saturated air initially.
FAX 051-974-4896
20 21
Global Service Network Location
CHINA / SHANGHAI
DongHwa Entec (Shanghai) Co., Ltd. RUSSIA / SAKHALIN
Hai Cheung (China) Ltd.-Shai Coens Energy Sakhalin Office
Euope
Asia North America
Middle East
JAPAN / NAGOYA
Tanabe Pneumatic Machinery Co., Ltd.
GREECE / PIRAEUS
Bosung Engineering (HELLAS) Ltd.
U.S.A / CALIFORNIA
Komarine Services
DongHwa Pneutec
U.S.A / CONNECTICUT
Africa
All Marine Spares
BANGLADESH
Hydro Machines Ltd.
South America
U.A.E / DUBAI INDIA
J.O. (M.E) Engineering L.L.C Sea Crest Marine Service
DINTEC DUBAI
DongHwa Pneutec
Head Office / Factory Seoul, Gyeonggi branch
U.A.E / DUBAI JAPAN / NAGOYA
Head Office / Factory Dintec Dubai Tanabe Pneumatic Machinery Co., Ltd.
(Gurang-dong) 75, Mieumsandan-ro 8 No. 201. Tameem House Building TECOM C 1, 1-Chome, Kawanish, Komaki, Aichi
beon-gil, Ganseo-gu, Busan,
(Gurang-dong) 75, Mieumsandan-ro 8beon-gil, Ganseo-gu, (Mongnae-dong) 283, Shinwon-ro, Danwon-gu, Ansan,
Tel : +971-(0)52-864-4674 Tel : +81-568-76-4191
Republic of Korea (Zipcode: 46748) Fax : +81-568-75-2627
Busan,Republic of Korea (Zipcode: 46748) Gyeonggi-do, Republic of Korea (Zipcode: 15602)
E-Mail : gdchoi@dintec.co.kr
Tel : +82-51-974-4800 E-Mail : info@tanacomp.co.jp
Fax : +82-51-974-4896
Seoul, Gyeonggi branch Tel : +82-51-974-4800 / Fax : +82-51-974-4896 Tel : +82-31-493-4801
KUWAIT TAIWAN / TAIPEI
(Mongnae-dong) 283, Shinwon-ro, Petroleum Equipment Technology Co. Soonex Co., Ltd.
Danwon-gu, Ansan, Gyeonggi-do, P.O. Box 10237, Shuaiba 65454 10F, 57, Sec 2, Tunhwa,S.Rodd,10681
Republic of Korea (Zipcode: 15602) Tel : +965-2398-7326 Tel : +886-2-2707-0137
Tel : +82-31-493-4801 Fax : +965 2398 6374 Fax : +886+-2-2701-0157
E-Mail : service@soonex.com.tw
E-Mail : infocomp@dhkomp.co.kr E-Mail: vjsimoes@petco.net
Hompage : www.dhkomp.co.kr SINGAPORE
Dintec (Singapore) Pte. Ltd.
CHINA / SHANGHAI RUSSIA / SAKHALIN 3 International Business Park, #05-13,
DongHwa Entec (Shanghai) Co., Ltd. Coens Energy Sakhalin Office Nordic European Centre
No. 2508, Jiangshan Road, Luchaogang 35A-2, Purkaeva Street, Yuzhno-Sakhalinksk Tel : +65-6896-4494
Tel : +86-21-5197-5001 Tel : +7-4242-460-841 Fax : +65-6896-4244
Fax : +86-21-5197-5005 E-Mail : Sakhalin@coens.com E-Mail : taufiq@dintec.com.sg
E-Mail : sbk@dh.co.kr
DongHwa Pneutec
Hai Cheung (China) Ltd.-Shai U.S.A / CALIFORNIA
INDIA Komarine Services
8/F, Grand Ocean Tower, No.1200 Pudong Avenue
Sea Crest Marine Service 923 E.F Street, Wilmington
Tel : +86-21-6888-9889 DongHwa Pneutec
‘P’Wing-005 Ground Floor Silent Park Tel : +1-310-780-6095
Fax : +86-21-6329-3888
Ne Ar Golden Nest E-Mail : joon.an@komarines.com
E-Mail: gus_hou@haicheungchina.com
Circle Mira-Bhayandeer Road, Mira Road-East,
GREECE / PIRAEUS Thane U.S.A / CONNECTICUT
Bosung Engineering (HELLAS) Ltd. Tel : +91-22-2855-2489 All Marine Spares
14, Skouze Street, 185,36 Fax : +91-22-2855-2587 375 Fairfield Ave., Building 5, Stamford,
Tel : +30-210-4187010 E-Mail : seacrests@gmail.com CT 06902
Fax : +30-210-4187011 Tel : +1-203-536-2674
E-Mail : bosung@bosunghellas.gr E-Mail : sales@allmarinespares.com
BANGLADESH
U.A.E / DUBAI Hydro Machines Ltd. BRAZIL / SAO PAULO
J.O. (M.E) Engineering L.L.C 15 New Baily Road 1st Floor Building #04 H.E. Power
598-1132, Dubai investment Park-1 Dhaka-1000 R.Sete de Abril n277, 6-Sal. A, Centro
Tel : +971-4882-9334 Tel : +880-2-9346780 Tel : +55-11-3258-3361
Fax : +971-4882-9338 Fax : +880-2-9341044 Fax : +55-11-3258-7721
E-Mail : info@jo-me.com E-Mail : office@hydro-machines.com E-Mail : he.power@Hotmail.com
22 23
Head Office / Factory
Mieum Industrial Complex, Gangseo-gu, Busan,
an 8 beongil 75 (gurangdong)
Tel : 051-974-4800 / Fax : 051-974-4896