Camber of BR No 458

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Camber of BR NO, 458 UP (1 y610 m) between

sectioon PTLD-SBE at KM
279/5-6
Pancl Required Camber (rcading is taken Percentage loss of
Span No. residual
Staff reading camber less than
Points using Auto levcl Machinc) 10%
camber (mm)
U/S (In mm) D/S (In mm) U/S (In mm) DIS (In mm) U/S D/S
LO 0.00 1692 1693 0.000 0.000 0
LI 21.95 1673 1673 21.125 21.500 3.76 2.05
L2 38.51 1660 1660 36.250 36.000 5.87 6.52
L3 51.60 1651 1648 47.375 49.500 8.19 4.07
L4 55.00 1650 1644 50.500 55.000 8.18 0.00
L5 51.60 1655 1651 47.625 49.500 7.70 4.07
L6 38.51 1665 1662 39.750 40.000 -3.22 -3.87
L7 21.95 1685 1682 21.875 21.500 0.34 2.05
L8 0.00 1709 1705 0.000 0.000 0.00

-SUVAJIT
VnecnpBPRA
SUVAJTpUTTA
DUTTA 2023.09.19 16:
SsE(BrlcoD

37:54+0530'

O Scanned with OKEN Scanner