Job No Sheet No Rev

1
Software licensed to Shinryo Corporation Part
CONNECTED User: Khun Rashaton
Job Title Ref

By Date02-Apr-22 Chd

Client File 24KV_Switchgear_12_MA Date/Time 27-Mar-2023 14:37

H-150x150x7x10, (Factored
Beam End Force Summary load )
The signs of the forces at end B of each beam have been reversed. For example: this means that the Min Fx entry gives the largest
tension value for an beam.
Axial Shear Torsion Bending
Beam Node L/C Fx Fy Fz Mx My Mz
(kg) (kg) (kg) (kg-m) (kg-m) (kg-m)
Max Fx 2751 2395 201:1.2DL+1.6L 3565.94 325.88 -67.15 0.05 -53.86 -450.53
Min Fx 1734 1730 211:0.9DL+1.6W -614.05 -319.99 140.12 0.45 -95.43 -592.77
Max Fy 2750 2394 212:0.9DL+1.6W 863.27 1163.37 -141.18 -0.32 -150.46 -177.48
Min Fy 2753 2335 203:1.2DL+1.0L 1077.21 -1761.80 59.55 -0.04 -52.90 -1490.67
Max Fz 1739 1730 208:1.2DL+1.0E 1063.42 -8.70 1590.50 0.11 -670.66 2.01
Min Fz 1780 1755 209:1.2DL+1.0E 1066.37 -43.97 -1594.84 -0.16 676.91 -19.10
Max Mx 1775 1754 209:1.2DL+1.0E 1840.91 -46.79 502.32 1.35 711.48 -37.53
Min Mx 1734 1564 205:1.2DL+1.0L 1697.97 136.18 -296.55 -1.18 -397.62 155.17
Max My 1775 1755 209:1.2DL+1.0E 1828.83 -46.79 502.32 1.35 837.06 -25.84
Min My 1734 1730 208:1.2DL+1.0E 1836.05 -80.56 -486.92 -0.89 -821.91 10.19
Max Mz 2750 2340 207:1.2DL+1.0E 2945.41 -632.12 -73.13 0.08 -106.50 1262.91
Min Mz 2751 2335 203:1.2DL+1.0L 2445.80 659.12 -58.74 -0.07 -57.91 -2157.25

Print Time/Date: 27/03/2023 15:15 STAAD.Pro CONNECT Edition 22.12.00.142 Print Run 1 of 1