Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Doc. Mat.

Serial
Project N° Unit Rev. Page
Type Code N°

215797C 501 PDS 0910 102 2 1

HMEL DOC. No.: 9112-501-TCS-131-00087


The present document or drawing is property of TECHNIP ENERGIES. and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose

[UNCONTROLLED COPY] Printed from TDMS dated: 18-September-2023, 10:42:14 AM by Mohit Parashar (10003230)
CLIENT : HPCL - MITTAL ENERGY LIMITED, GGSR BATHINDA (PUNJAB)

PROJECT : DETAILED ENGINEERING OF CDU REVAMP PROJECT

HMEL PROJECT NO. : A-ER501-23-23-02-1

OWNER CONSULTANT

TECHNIP ENERGIES LTD.


and in any way other than that for which it is specifically furnished or outside the extent of the agreed upon right of use.

HPCL-MITTAL ENERGY
LIMITED, GGSR, BATHINDA, NOIDA, INDIA.

PUNJAB

PROCESS DATA SHEET


2nd STAGE DESALTING/DESLUDGING WATER PUMPS
(501-P-102N A/B)

Pages modified under this revision: 1,2,3,4.

Kunche Sravan Prosenjit Paul Prosenjit Paul


2023.09.15 2023.09.15 19:17:00 2023.09.15
19:15:07 +05'30' +05'30' 19:17:12 +05'30'

2 14/09/2023 Issued for Review (IFR) KSS PSP PSP


1 26/05/2023 Issued for Design (IFD) SS SG CH
0 24/05/2007 Issued for Engineering (EIL Ref : 6812-501-02-
DS-1602)
A 13/04/2007 Issued for Comments (EIL Ref : 6812-501-02- ANB VRK AG
DS-1602)
Date WRITTEN BY CHECKED BY APPROVED BY
Rev STATUS
DD/MMM/YYYY (name & visa) (name & visa) (name & visa)

DOCUMENT REVISIONS

Sections changed in last revision are identified by a line in the right margin
CLIENT HMEL

LOCATION BATHINDA PROCESS DATA SHEET


2ND STAGE DESALTING/DESLUDGING WATER PUMPS

[UNCONTROLLED COPY] Printed from TDMS dated: 18-September-2023, 10:42:14 AM by Mohit Parashar (10003230)
(501-P-102 N A/B)
UNIT 501

RECORD OF REVISIONS

Rev. Date Revision Details

2 14.09.2023 1. Detailed Engineering Changes

Page 2

The present document or drawing is property of TECHNIP ENERGIES INDIA LTD. and shall not, under any circumstances, be totally or partially, directly
or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for
which it is specifically furnished or outside the extent of the agreed upon right of use.
PROCESS DATA SHEET
Project N° - Unit Doc. type Mat. Code Serial N° Rev. index

215797C-501 PDS 0910 102 2

CLIENT HMEL Rev. Date Made by Checked by Page


A 13/04/2007 ANB VRK

Revision
LOCATION BATHINDA CENTRIFUGAL 0 24/05/2007
PUMPS 1 26/05/2023 SS SG 3
UNIT 501 2 14/09/2023 KSS PSP

[UNCONTROLLED COPY] Printed from TDMS dated: 18-September-2023, 10:42:14 AM by Mohit Parashar (10003230)
1
2 ITEM NORMAL OPERATION 501-P-102N A
3 SPARE ITEM 501-P-102N B
4 ( NOTE-1,2,3)
5 NUMBER (1 W + 1 S)
6
7 SERVICE 2ND STAGE DESALTING
8 /DESLUDGING WATER PUMPS
9
10 Product DESALTER WATER
11
12 Auto-ignition temperature °C -
13
HANDLED PRODUCT

14 Corrosive/Erosive YES / NO
15
16 Normal pumping temp. Tp °C 70
17
18 Viscosity at Tp cP 0.4
19
20 Vapor pressure at Tp Kg/cm2a 0.32
21
22
23
24 Specific gravity at Tp 0.978
25
26
27 Normal flowrate m³/h 178
28 Minimum flowrate m³/h 89 (NOTE-8)
29 Rated flowrate m³/h 195.8
30
31 Discharge pressure Kg/cm2g 29.2 2
32
33 Suction pressure Kg/cm2g 0.94 2
34
2 28.26
35 Differential pressure * Kg/cm 2
PUMP

36
37 Differential height (A) m 289
38
39 Available NPSH m >8
40
41 Normal shaft power (est.) kW 261.39 (NOTE-7)
42 Normal electrical consumption (est.) kW 280 (NOTE-7)
43
44 Design temperature (B) °C 100
45
2 40.3 (NOTE-6)
46 Discharge design pressure Kg/cm g 2
47
48
49 Driver type : normal ELECTRICAL MOTOR
50 spare ELECTRICAL MOTOR
51 Speed control Yes/No NO
52 speed control by :
53 Turbine speed control Manual/Auto N/A
54
55 Expected speed range N/A
56
57 Open valve start-up Yes/No YES
58
59 GENERAL NOTE
60 (A) The choice of a pump having a max. height more than 1.2 time the height at design point shall be submitted to the Process Dept approval.
61 (B) Maximum temperature. If lower than minimum winter temperature, depressuring temperature (pump stopped) shall also be specified.
62 NOTES : SEE PAGE 4
63
64
65
66
67
68
PDS 84 - Rev.8 - ANG -XL97 PD084A18

The present document or drawing is property of TECHNIP ENERGIES INDIA LIMITED. and shall not, under any circumstance, be totally or partially, directly or indirectly, transferred,
reproduced, copied, disclosed or used, without its prior consent, for any purpose and in anyway other than that for which it is specifically furnished or outside the extent of the agreed
upon right of use.
PROCESS DATA SHEET
Project N° - Unit Doc. type Mat. Code Serial N° Rev. index

215797C-501 PDS 0910 102 2

CLIENT HMEL Rev. Date Made by Checked by Page


A 13/04/2007 ANB VRK

Revision
LOCATION BHATINDA CENTRIFUGAL 0 24/05/2007
PUMPS 1 26/05/2023 SS SG 4
UNIT 501 2 14/09/2023 KSS PSP

[UNCONTROLLED COPY] Printed from TDMS dated: 18-September-2023, 10:42:14 AM by Mohit Parashar (10003230)
1 NOTES:
2
3 1. DATA GIVEN IS FOR EACH PUMP.
4 2. ONE WORKING AND ONE STANDBY PUMP.
5 3. EXISTING PUMP REPLACEMENT WITH NEW HIGHER CAPACITY PUMP ALONG WITH MOTOR HAS BEEN CONSIDERED.
6 4. SINGLE MECHANICAL SEAL TYPE-A ARRANGEMENT WITH FLUSHING PLAN 11/61 IS SUITABLE. TO BE CONFIRMED BY VENDOR 2
7 5. MOC FOR CASING SHALL BE KCS AND IMPELLER SHALL BE KCS
10 6. PUMP VENDOR TO LIMIT THE SHUT-OFF PRESSURE UPTO 40.3 KG/CM2G 2
11 7. ESTIMATED VALUES BASED ON ASSUMED PUMP EFFICIENCY OF 52.4% . TO BE CONFIRMED BY PUMP VENDOR. 2
12 8. MENTIONED FLOW RATES ARE PROCESS REQUIREMENT EXCLUDING ANY MINIMUM FLOW (MCF)
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
PDS 84 - Rev.8 - ANG -XL97 PD084A18
The present document or drawing is property of TECHNIP ENERGIES INDIA LIMITED. and shall not, under any circumstance, be totally or partially, directly or
indirectly, transferred, reproduced, copied, disclosed or used, without its prior consent, for any purpose and in anyway other than that for which it is specifically
furnished or outside the extent of the agreed upon right of use.

You might also like