The document describes the ISOIL P.D. Meter series BM/GPL, which offers high accuracy liquid petroleum gas (LPG) measurement over a wide range of flow rates. The meters maintain constant accuracy over long periods of use and can display flow rates visually. They are suitable for loading tank trucks and custody transfer applications. Associated valves and filters are also described to ensure accurate measurement and protect the meter. Technical specifications are provided for meter sizes 3", 4" and 6", including flow ranges, materials, flange standards, and an accuracy of ±0.3%.
The document describes the ISOIL P.D. Meter series BM/GPL, which offers high accuracy liquid petroleum gas (LPG) measurement over a wide range of flow rates. The meters maintain constant accuracy over long periods of use and can display flow rates visually. They are suitable for loading tank trucks and custody transfer applications. Associated valves and filters are also described to ensure accurate measurement and protect the meter. Technical specifications are provided for meter sizes 3", 4" and 6", including flow ranges, materials, flange standards, and an accuracy of ±0.3%.
The document describes the ISOIL P.D. Meter series BM/GPL, which offers high accuracy liquid petroleum gas (LPG) measurement over a wide range of flow rates. The meters maintain constant accuracy over long periods of use and can display flow rates visually. They are suitable for loading tank trucks and custody transfer applications. Associated valves and filters are also described to ensure accurate measurement and protect the meter. Technical specifications are provided for meter sizes 3", 4" and 6", including flow ranges, materials, flange standards, and an accuracy of ±0.3%.
series BM/GPL 200 - 400 - 600 Data sheet: DS/CO/0003/EN Ed. 07-2017
ISOIL P.D. METER series BM/GPL sizes 3”, 4” and 6”
offers high accuracy over a large range of flow rates. This accuracy remains constant despite long periods of use. Visual indication of the measured flow rate can be obtained when associated with an electronic flow computer directly mounted on the meter or remotely connected to it by means of a pulse emitter such as VEGA II or VEGA T.
Applications Tank trucks or rail tank wagons loading. Custody transfer lines.
Filtering and air elimination
To assure a measuring accuracy and preserve the meter from damage, the fluid under measurement must be properly filtered and air or gas must be eliminated. Isoil produces a wide range of strainers and strainer-air separators. Isovalve type 2SLDR-FT/GPL Downstream of the P.D. Meter, a special automatic valve may be installed.