Typical Application
+5V
VBUS
RT
D+
RT
D-
GND
Ordering Information
Part Number Ambient Temperature Range Package Environmental
AOZ8904CIL SOT-23-6 RoHS Compliant
-40°C to +85°C
AOZ8904HIL SC-70-6 Green Product
AOS Green Products use reduced levels of Halogens, and are also RoHS compliant.
Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information.
Pin Configuration
CH1 1 6 CH4
VN 2 5 VP
CH2 3 4 CH3
SOT-23-6 / SC-70-6
(Top View)
Parameter Rating
VP – VN 6V
Peak Pulse Current (IPP), tP = 8/20µs 4A
Peak Power Dissipation (8 x 20µs@ 25°C) 50W
Storage Temperature (TS) -65°C to +150°C
ESD Rating per IEC61000-4-2, contact(1) ±24kV
ESD Rating per IEC61000-4-2, air(2) ±24kV
ESD Rating per Human Body Model(2) ±24kV
Junction Temperature (TJ) -40°C to +125°C
Notes:
1. IEC 61000-4-2 discharge with CDischarge = 150pF, RDischarge = 330Ω.
2. Human Body Discharge per MIL-STD-883, Method 3015 CDischarge = 100pF, RDischarge = 1.5kΩ.
Electrical Characteristics
TA = 25°C unless otherwise specified
Notes:
3. These specifications are guaranteed by design.
4. The working peak reverse voltage, VRWM, should be equal to or greater than the DC or continuous peak operating voltage level.
5. VBR is measured at the pulse test current IT.
6. Measurements performed with no external capacitor on VP (Pin 5 floating).
7. Measurements performed with VP biased to 3.3 Volts (Pin 5 @ 3.3V).
8. Measurements performed using a 100 nSec Transmission Line Pulse (TLP) system.
Clamping Voltage vs. Peak Pulse Current I/O – Gnd Insertion Loss (S21) vs. Frequency
(tperiod = 100ns, tr = 1ns) (Vp = 3.3V)
17 1
0
16
Clamping Voltage, VCL (V)
-1
6
0
Forward Voltage (V)
4 -20
3 -40
2
-60
1
0 -80
0 2 4 6 8 10 12 10 100 1000
Forward Current, IPP (A) Frequency (MHz)
-2
-3
-4
-5
-6
-7
-8
-9
-10
1 10 100 1000
Frequency (MHz)
TPBIASx
1μ 56Ω 56Ω
TPBx+
TPBx-
56Ω 56Ω
GND
5.1kΩ 270p
AOZ8904
LEGAL DISCLAIMER
Applications or uses as critical components in life support devices or systems are not authorized. Alpha and Omega
Semiconductor does not assume any liability arising out of such applications or uses of its products. AOS reserves
the right to make changes to product specifications without notice. It is the responsibility of the customer to evaluate
suitability of the product for their intended application. Customer shall comply with applicable legal requirements,
including all applicable export control rules, regulations and limitations.
AOS' products are provided subject to AOS' terms and conditions of sale which are set forth at:
http://www.aosmd.com/terms_and_conditions_of_sale
ALPHA AND OMEGA SEMICONDUCTOR PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL
COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS.
As used herein:
1. Life support devices or systems are devices or 2. A critical component in any component of a life
systems which, (a) are intended for surgical implant into support, device, or system whose failure to perform can
the body or (b) support or sustain life, and (c) whose be reasonably expected to cause the failure of the life
failure to perform when properly used in accordance support device or system, or to affect its safety or
with instructions for use provided in the labeling, can be effectiveness.
reasonably expected to result in a significant injury of
the user.