ASB - BK117 D2 26 004 Rev3 EN
ASB - BK117 D2 26 004 Rev3 EN
Summary:
With this Alert Service Bulletin (ASB), Airbus Helicopters prescribe a first time and a scheduled
inspection of the portable fire extinguisher “EN” (European standard EN4649) and the
replacement with a portable fire extinguisher “UL” (Underwriters Laboratory standard
UL2129).
This ASB provides the TC holders instruction linked to EASA AD 2021-0185R1.
A A
1.C REASON
Supplier UMLAUT told Airbus Helicopters that the portable fire extinguisher P/N
U262A50T1001 (manufacturer's P/N P3APP003010A) can have an incorrect operation
because of high temperatures (approximately 70 °C) during a long period. Because of
the high temperatures exposure, the pressure in the extinguisher increases and leads
to an inoperative portable fire extinguisher.
Thus, Airbus Helicopters prescribes a first time and a scheduled inspection of the
portable fire extinguishers.
Now, that the “UL” version of the portable fire extinguisher is available, Airbus
Helicopters prescribe the installation of the new halon‐free portable fire extinghisher
that satisfies the environmental requirements specified in the UL standard before
31.12.2022.
After the replacement of the portable fire extinguisher “EN” with the “UL”, the
inspection according this ASB is no longer required.
Do a first time inspection and a scheduled inspection of the portable fire extinguisher.
1.E COMPLIANCE
Do an inspection of the portable fire extinguisher in accordance with Section 3.B within
the next 30 days after receipt of Revision 0 of this ASB.
Replace the portable fire extinguisher “EN” with the “UL” in accordance with Section
3.B.4 by 31.12.2022 at latest.
After the replacement, the inspection as defined in PART 2 of this ASB is no longer
required.
Receipt of ASB
30 days
PART 1
Do an inspection of the portable fire extinguisher for a
possible gap between the safety pin and the valve head
Upto 31.12.2022
scheduled inspection
(each month), refer to
MSM 05-25-00 of the
portable
fire extinguisher
Replace the portable fire
extinguisher, obey MMEL
(MEL)
PART 3
Flow chart
1.F APPROVAL
1.K REFERENCES
AMM MBB‐BK117 D‐2, MMEL MBB-BK117 D-2 and MSM MBB-BK117 D-2.
SB MBB-BK117 D-2-26-003.
PART 1 / PART 2
PART 3
NOTE
The recording of compliance with ASBs in the R-Tex
tool does not replace the recording in the helicopter
documents
4 APPENDIX
None.