Professional Documents
Culture Documents
0405 HP ADDIS Lighting Design Client & ID Consolidated
0405 HP ADDIS Lighting Design Client & ID Consolidated
0405 HP ADDIS Lighting Design Client & ID Consolidated
Hahu Bahru:
HYATT PLACE
ADDIS ABABA
March 2022
Rev A
LEYAT HOTELS
PLC
N/A - Part of
North
HYATT PLACE
South West
East
South West East
South
Client approves
this kind of pool
lighting.
West East
7
7
7
3
2 6
5 LED ins cove
(ADA)
3 Lift lighting to be consistent
2 throughout project
1
4
LED in recessed as shown-
please see ceiling co
ordination drawings for
Suspended linear light over proposed positions
bar/market/host station
Lighting below walkway?
Could be the same as the
stairway light?
8
General - for each level,
4
Stairway light in side would it be possible to have
cladding detail to be a general introduction of the
developed during concept /objectives be
documentation stage - see explained with description
attached screenshot for and/or images? Example -
reference lighting here? what atmosphere will be
created with the lighting,
6 what the goals are for the
lighting in the space, what's
the highlighted elements,
7
what the user experience
through the space (example
8 inviting and relaxed for GF
7. All restroom lighting to be
consistent throughout project - linear lounge area with highlighting
Circular lighting fine, it might need to
light as per 3D's preferred (as host/market station ; moody
move to the edge of the circle due to
shown on one of the bathroom and energetic for rooftop bar
the woven material, but must be
5 proposals in this document) etc) , colour rendering, will
developed during documentation
there be daytime/dusk/
stage.
nighttime settings, etc, and
if so what is the aim of each
LEYAT HOTELS Hyatt Place Addis Ababa - Lighting Concept setting , etc
PLC March 2022
There is a ceiling height
3
wall lights here
4
6
2
Lift lighting to be consistent
LED in ceiling throughout project, LED in
recess ceiling recess around
This is a continuous ceiling -
so all lighting need to line up
and read well together, we
propose to have a linear
3 1 light that lines up with the
3 walkway here
1 2
1
5 1
4
All restroom lighting to be consistent
throughout project - linear light as
per 3D's preferred (as shown on one
of the bathroom proposals in this
document)
5
Lift lighting to be consistent
2
throughout project, LED in
ceiling recess around
1
2
3
LED ins cove
(ADA)
4
5
Other services
must be on flat
surface - detail
to be
Option 2 - Flush downlights in developed
3
meeting spaces
ceiling height
very low,
please keep to 2
flush units in
ceiling
1
2
2
8
9
all outdoor lighting part of
5 architectural scope
6
8 9
5 part of arch
7 rather from ceiling recess scope, but we
like this option
for pool
LEYAT HOTELS Hyatt Place Addis Ababa - Lighting Concept
PLC March 2022
END OF PRESENTATION
THANK YOU