Motorized Roller Blind

Mytec AT-K220

Motorized roller blind with ultra-quiet operation.


Its synchronous motors allow different sizes of
roller blinds to go up and down at the same speed.
Power consumption is drastically reduced.
Ideal for environment-friendly buildings and offices.
The small gap (14 mm per side) between the
screen and main body.
The snap bracket is available for easy installation
and removal.
Mytec AT-K220
0\WHF$7.·V8QLTXH)HDWXUHV
0
● The motorized Roller Blind, Mytec AT-K220 operates noiselessly.
Very quiet 10
(35 dB or less in a no-load state). 20

● The Controller and Infra-red Remote-control Receiver are built Late at night in the suburbs 30
35 dB
40
into the Set Bar for high visual appeal. Library, hospital
50

● The small gap (14 mm per side) between the screen and main Normal conversation 60

body simplifies the design. 70

80
● The main unit is easily installed with the snap bracket. Noisy office
90

100 (dB)
● Less than 10 W power consumption per unit.
dB: A unit of loudness. To the human ear,
● Operated by the synchronous motor: Roller Blinds of different a reduction of 10 dB is perceived as an
approximately 50 percent reduction of
sizes and weights rise in unison when several blinds go up and loudness.

down at the same time.

All Roller Blinds stop at the same position


without disturbance.

Simultaneous receiving

Structure Drawing
Product View
3RZHU&RUGP ɇ

52 mm
(2.0ɇ)

40 mm
(1.6ɇ)
Product width (W)
93 mm (3.7ɇ)

77 mm (3.0ɇ)
77 mm
93 mm (3.0ɇ)
(3.7ɇ)
40 mm 52 mm
(1.6ɇ) (2.0ɇ)

14 mm (.55ɇ) 14 mm (.55ɇ)
16 mm (.63ɇ)* 16 mm (.63ɇ)*

* Dimensions for the ratio of the width and height is 1:3 or more.

Components and Materials


No. Components Material No. Components Material
MTAT Set Bar Aluminum Side Holder Steel, Molded resin

MT03 Bracket Steel, Molded resin MT03 Weight Bar Molded resin

MTAT Main Controller − MT03 Weight Bar Cap Molded resin

Side Holder Receiver Side Steel, Molded resin Infra-red Remote-Control Receiver Molded resin

2
Mytec AT-K220

Bracket Weight Bar


25 mm (.98ɇ) Non wrapping type Wrapping type
11 mm 12 mm
(.43ɇ) (.47ɇ)

52 mm (2.0ɇ)

18 mm (.71ɇ)

27 mm (1.1ɇ)

Product Width Number of Bracket

PP ɇ RUOHVV 2

PP ɇ ²PP ɇ 3

PP ɇ RUPRUH 4

Motor Specifications

Rated voltage AC220V Rated frequency 21/25rpm

Rated frequency 50/60Hz Working temperature range 0–50°C (No condensation)

Power consumption During standby 1W/During operation 9W Rated time Continuous operation 2 minutes

Operating voltage DC5V

Operating current 1mA

Allowable Size Product Weight

Width ²PP ²ɇ 4.1 kg (9.0 lb)


Height ²PP ²ɇ
ZLGWKPPɇZLWKRXWVFUHHQ
*When using Balancer N
Ratio (W:H) 1:8 (limit)

*Depending on the screen weight and material.

3
Mytec AT-K220

Typical Roll-up Diameter

Ceiling attachment Wall attachment


A
Roll-up dia. 77 mm
ɇ

77 mm
2

ɇ
A

Roll-up dia. Roll-up dia.

Roll-up dia.
2

Roll-up dia.
A = 77 +
2

Class Height 400 mm 800 mm 1200 mm 1600 mm 2000 mm 2400 mm 2800 mm 3000 mm
7KLFNQHVV ɇ (32ɇ (47ɇ (63ɇ (79ɇ (94ɇ (110ɇ (118ɇ
–0.20 mm
A ²ɇ  46 mm ɇ 47 mm (1.9ɇ 48 mm (1.9ɇ 50 mm (2.0ɇ 51 mm (2.0ɇ 52 mm (2.0ɇ 53 mm (2.1ɇ 53 mm (2.1ɇ

0.21–0.30 mm
B ²ɇ  47 mm ɇ 49 mm (1.9ɇ 50 mm (2.0ɇ 52 mm (2.0ɇ 53 mm (2.1ɇ 55 mm (2.2ɇ 56 mm (2.2ɇ 57 mm (2.2ɇ

0.31–0.40 mm
C ²ɇ  48 mm ɇ 50 mm (2.0ɇ 52 mm (2.0ɇ 54 mm (2.1ɇ 56 mm (2.2ɇ 58 mm (2.3ɇ 60 mm (2.4ɇ 60 mm (2.4ɇ

0.41–0.50 mm
D ²ɇ  49 mm ɇ 51 mm (2.0ɇ 54 mm (2.1ɇ 56 mm (2.2ɇ 59 mm (2.3ɇ 61 mm (2.4ɇ 63 mm (2.4ɇ 64 mm (2.5ɇ

0.51–0.60 mm
E ²ɇ  50 mm ɇ 53 mm (2.1ɇ 56 mm (2.2ɇ 58 mm (2.3ɇ 61 mm (2.4ɇ 63 mm (2.4ɇ 66 mm (2.6ɇ 67 mm (2.6ɇ

0.61–0.70 mm
F ²ɇ  50 mm ɇ 54 mm (2.1ɇ 57 mm (2.2ɇ 60 mm (2.4ɇ 63 mm (2.4ɇ 66 mm (2.6ɇ 69 mm (2.7ɇ 70 mm (2.8ɇ

0.71–0.80 mm
G ²ɇ  51 mm ɇ 55 mm (2.2ɇ 59 mm (2.3ɇ 62 mm (2.4ɇ 65 mm (2.6ɇ 69 mm (2.7ɇ 72 mm (2.8ɇ 73 mm (2.9ɇ

0.81–0.90 mm
H ²ɇ  52 mm ɇ 56 mm (2.2ɇ 60 mm (2.4ɇ 64 mm (2.5ɇ 68 mm (2.7ɇ 71 mm (2.8ɇ 74 mm (2.9ɇ —

0.91–1.00 mm
I ²ɇ  53 mm ɇ 57 mm (2.2ɇ 62 mm (2.4ɇ 66 mm (2.6ɇ 70 mm (2.8ɇ 73 mm (2.9ɇ — —

*The roll-up diameter might be actually different.


*Please contact our local agent for another size.

4
Mytec AT-K220

Overall Structure Drawing

Window side

Box width = Product width (W) + 1PP ɇ

5 mm (.20ɇ Product width (W) 5 mm (.20ɇ

70 mm
(2.8ɇ
77 mm 52 mm 150 mm
(3.0ɇ (2.0ɇ (5.9ɇ
80 mm
(3.2ɇ

Room side

150 mm (5.9ɇ

52 mm (2.0ɇ
Room Window
side 40 mm side
(1.6ɇ

77 mm
(3.0ɇ
14 mm (.55ɇ 14 mm (.55ɇ
16 mm (.63ɇ * 16 mm (.63ɇ * 150 mm
(5.9ɇ

5 mm (.20ɇ Product width (W) 5 mm (.20ɇ

Box width = Product width (W) + 1PP ɇ

* Dimensions for the ratio of the width and height is 1:3 or more.

5
Mytec AT-K220

Basic Wiring and Connecting Diagram

Infra-red Remote-control Operation

Basic Wiring Diagram

VVFѮ1.6×2C E1.6 (separate work)

← To 220 VAC power source

220 VAC power outlet


with ground connection
(Separate work)

Power Cord →

Infra-red Remote-control
Receiver

Infra-red Remote-control
Transmitter

FM Remote-control Operation
*When using FM Remote-control Receiver 2.4 G-IR

Basic Wiring Diagram


VVFѮ1.6×2C E1.6 (separate work)

←To 220 VAC power source

220 VAC power outlet


with ground connection
(Separate work)
Mytec AT Connect Cord for FM-IR

Power Cord →

FM Remote-control
Receiver 2.4 G with IR Terminal

FM Remote-control Transmitter 2.4 G

Explanatory notes: Power supply, Low voltage control line, Main body attachment or TOSO standard

6
Mytec AT-K220

FM Remote-control Operation
*When using FM Remote-control Receiver 2.4 G

Basic Wiring Diagram

VVFѮ1.6×2C (separate work)

←To 220 VAC power source

220 VAC power outlet 220 VAC power outlet


(separate work) FM Remote-control Connector Non Voltage type (separate work)

Power Cord

Modular Cord (6-pole) with Terminal


Terminal Block FM Remote-control
Receiver 2.4 G
Mytec AT Connect Cord for Switch

FM Remote-control Transmitter 2.4 G

Basic Connecting Diagram

←To 220 VAC power source

Yellow Green
Close Stop Both Open

Green Black
Red White
Black Red

Terminal Block
FM Remote-control
Receiver 2.4 G

FM Remote-control Transmitter 2.4 G

7
Mytec AT-K220

3-Button Switch Operation


Single Operation

Basic Wiring Diagram

VVFѮ1.6×2C (separate work)


VCTF0.75□×4C
or CVV1.25□×4C (separate work)
←To 220 VAC power source

220 VAC
power outlet For one recessed 6-pole modular outlet
(separate work)
Modular Cord (6-pole)

Mytec AT Connect Cord


Power Cord → for Switch

3-Button Switch

Basic Connecting Diagram

←To 220 VAC power source


Red
Black
Green
White

OPEN

STOP

CLOSE

3-Button Switch

Explanatory notes: Power supply, Low voltage control line, Main body attachment or TOSO standard

8
Mytec AT-K220

Simultaneous Operation

Basic Wiring Diagram

VVFѮ1.6×2C (separate work) VCTF0.75□×4C or CVV1.25□×4C (separate work)

←To 220 VAC power source

220 VAC
power outlet For one recessed 6-pole modular outlet
(separate work)
Modular Cord (6-pole)

Power Cord → Mytec AT Connect Cord for Switch

3-Button Switch

Basic Connecting Diagram

←To 220 VAC power source


Red

Red

Red
Black

Black

Black
Green

Green

Green
White

White

White
Red
Black
Green
White

OPEN

STOP

CLOSE

3-Button Switch

9
Mytec AT-K220

Simultaneous Selection Operation

Basic Wiring Diagram


VCTF0.75□×4C or
VVFѮ1.6×2C (separate work) CVV1.25□×4C (separate work)

←To 220 VAC power source

220 VAC power outlet For one recessed 6-pole


(separate work) modular outlet
Modular Cord (6-pole)

Mytec AT Connect
Power Cord → Cord for Switch

ALL Switch Switch Switch 1 2 3


switches 1 2 3

3-Button Switch

Basic Connecting Diagram

←To 220 VAC power source


Red

Red

Red

Red

Red

Red
Black

Black

Black

Black

Black

Black
Green

Green

Green

Green

Green

Green
White

White

White

White

White

White
Red

Red

Red

Red
Black

Black

Black

Black
Green

Green

Green

Green
White

White

White

White

OPEN OPEN OPEN OPEN

STOP STOP STOP STOP

CLOSE CLOSE CLOSE CLOSE

ALL switches Switch 1 Switch 2 Switch 3 1 2 3

3-Button Switch

Explanatory notes: Power supply, Low voltage control line, Main body attachment or TOSO standard

10
Mytec AT-K220

Mytec AT-K220 Body

Product Name

Mytec AT-K220

*&RUGOHQJWKP ɇ

Mytec AT-K220 Parts

Operation
Infra-red FM Remote-Control Product
Product Name FM Remote-Control
Remote-Control Receiver 2.4G 3-Button Switch Code
Receiver 2.4G
Receiver with IR

Infra-red Remote-Control
Receiver 01
00510184
*Use if the receiver part is not exposed.
( 1)
*
*&RUGOHQJWKP ɇ
*$YDLODEOHFKDQJLQJDQJOHDSSUR[Ý
Infra-red Receiver 01 Connect Cord
145 mP ɇ

04800002
( 1)
*
Use if the receiver part is not exposed.
*
Infra-red Remote-Control
Transmitter 01N 00510297

Infra-red Remote-Control ( 2)
Transmitter 02 * 00510281

FM Remote-Control
Transmitter 2.4G
02390040

FM Multi Remote-Control ( 2)
* ( 2)
*
Transmitter 2.4G
30006411

FM Remote-Control
Receiver 2.4G 02390042
with IR Terminal

FM Remote-Control
Receiver 2.4G
02390043

FM Remote-Control
Connector 02390036
(Non Voltage type)

Modular Cord
(6-pole, 4-core) 00510229
with Terminal

*12 Use if necessary.


* Use one of the transmitters.

11
Mytec AT-K220

Operation
Infra-red FM Remote-Control Product
Product Name FM Remote-Control
Remote-Control Receiver 2.4G 3-Button Switch Code
Receiver 2.4G
Receiver with IR

Mytec AT Connect Cord


for FM-IR 30005768

*&RUGOHQJWKP ɇ
Mytec AT Connect Cord
for Switch
170 mm (ɇ
30006833

MO Inlay Switch Wide 3 Buttons A


00510307

MO Wide Switch Wide Plate 1 Row


00510309

Modular Cord 1 m (6-pole, 4-core)


02380002

Inlay Modular Connector (6-pole)


Body 1 Jack 00510269

MO Switch Plate 1 Button 1 Row


00510259

201602E